Hydrophone TC4014
Hydrophone TC4014
Hydrophone TC4014
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Hydrophone</strong> <strong>TC4014</strong><br />
Broad Band Spherical <strong>Hydrophone</strong><br />
<strong>TC4014</strong><br />
• Wide usable frequency range<br />
• Omnidirectional in all planes<br />
• Built-in low noise preamplifier<br />
• Long term stability<br />
• Individually calibrated<br />
The <strong>TC4014</strong> broad band spherical hydrophone offers a very wide usable<br />
frequency range with excellent omnidirectional characteristics in all planes.<br />
The overall receiving characteristics makes the <strong>TC4014</strong> an ideal transducer<br />
for making absolute underwater sound measurements up to 480kHz. The<br />
wide frequency range also makes the <strong>TC4014</strong> perfect for calibration purposes,<br />
particularly in higher frequencies.<br />
The <strong>TC4014</strong> incorporates a low-noise 26dB preamplifier providing signal<br />
conditioning for transmission through long underwater cables.<br />
The <strong>TC4014</strong> features an insert calibration facility, which allows for a reliable<br />
test of the hydrophone. The <strong>TC4014</strong> is available with integrated SUBCON<br />
BGH MGP connector. Ask for TC4039.<br />
The sensor element is permanently encapsulated in Special formulated NBR<br />
to ensure long term reliability. The rubber has been specially compounded to<br />
ensure acoustic impedance close to that of water. The hydrophone and<br />
connector housing are made of corrosion resistant aluminum-bronze.<br />
TECHNICAL SPECIFICATIONS<br />
Usable Frequency range: 15Hz to 480kHz<br />
Linear Frequency range: 30Hz to 100kHz ±2dB 25Hz to 250kHz ±3dB<br />
Receiving Sensitivity:<br />
-186dB ±3dB re 1V/µPa<br />
Horizontal directivity:<br />
Omnidirectional ±2dB at 100kHz<br />
Vertical directivity:<br />
270° ±2dB at 100kHz<br />
Operating depth:<br />
900m<br />
Survival depth:<br />
1200m<br />
Operating temperature range: -2°C to +55°C<br />
Storage temperature range: -40°C to +80°C<br />
Weight in (air):<br />
650g without cable<br />
Max. output voltage:<br />
≥2.8Vrms (at 12VDC)<br />
Preamplifier gain:<br />
26dB<br />
Supply voltage:<br />
12 to 24VDC<br />
High pass filter:<br />
15Hz -3dB<br />
Calibration path attenuation: at 10kHz 14dB<br />
Current consumption:<br />
<strong>Hydrophone</strong> <strong>TC4014</strong><br />
Broad Band Spherical <strong>Hydrophone</strong><br />
Documentation:<br />
Receiving sensitivity: Individually calibration curves: Sensitivity at ref.: frequencies:<br />
At 5 kHz to 500 kHz<br />
250 Hz<br />
Horizontal directivity:<br />
At 100, 200, 300 kHz<br />
Vertical directivity:<br />
At 100, 200, 300 kHz<br />
Horizontal <strong>TC4014</strong>-1 directivity Receiving patternDirectional Response<br />
0 dB<br />
-3 dB<br />
-10 dB<br />
-20 dB<br />
-30 dB<br />
-90 ō 60 o -30 o 0 o 30 o 60 o 90 o<br />
-40 dB<br />
-170<br />
-175<br />
-180<br />
-185<br />
-190<br />
-195<br />
-200<br />
Receiving Receiving Sensitivity Response [dB re 1V/µPa [dB re @ 1V/µPa 1m] @ 1m]<br />
-205<br />
-120 o<br />
-150 o<br />
-180 o<br />
150 o<br />
120 o<br />
100kHz<br />
200kHz<br />
300kHz<br />
-210<br />
6 8 10 20 40 60 80 100 200 400<br />
Frequency [kHz]<br />
<strong>TC4014</strong>-1 Vertical directivity Receiving patternDirectional Response<br />
0 dB<br />
-3 dB<br />
-10 dB<br />
-20 dB<br />
-30 dB<br />
-90 ō 60 o -30 o 0 o 30 o 60 o 90 o<br />
-40 dB<br />
dB re 1 µPa / √ Hz<br />
Typical equivalent Equivalent noise noise pressure spectrumcurve<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
Seastate zero<br />
<strong>TC4014</strong><br />
Wenz's minimum<br />
Thermal water noise<br />
10 100 1000 10000 100000<br />
Frequency [Hz]<br />
-120 o<br />
120 o<br />
-150 o<br />
-180 o<br />
150 o<br />
100kHz<br />
200kHz<br />
300kHz
<strong>Hydrophone</strong> <strong>TC4014</strong><br />
Broad Band Spherical <strong>Hydrophone</strong><br />
Accessories for <strong>TC4014</strong><br />
TL8042<br />
Std.: 10m extension<br />
Opt.: Different length on request<br />
TL8056<br />
Std.: 10m extension<br />
Opt.: Different length on request<br />
TL8092<br />
Std.: 10m extension<br />
Opt.: Different length on request<br />
Use cable TC8092 to make<br />
direct connection to<br />
EC6070 or EC6073
<strong>Hydrophone</strong> <strong>TC4014</strong><br />
Broad Band Spherical <strong>Hydrophone</strong><br />
Outline Dimensions<br />
Electrical Diagram<br />
RESON reserves the right to change specifications without notice. © 2005 RESON A/S<br />
For Acoustical Measurement Accuracy please refer to www.reson.com or contact sales.<br />
RESON A/S RESON GmbH RESON-Telenav Electronics<br />
Denmark Germany Pte. Ltd.<br />
Tel: +45 4738 0022 Tel: +49 431 720 7180 Singapore<br />
E-mail: reson@reson.dk E-mail: reson@reson-gmbh.de Tel: +65-6-872-0836<br />
E-mail: sales@reson.sg<br />
RESON Inc.<br />
RESON B.V.<br />
USA The Netherlands RESON SA (PTY) LTD.<br />
Tel: +1 805 964-6260 Tel: +31 (0)10 245 1500 South Africa<br />
E-mail: sales@reson.com E-mail: info@reson.nl Tel: +27 21 701-1720<br />
E-mail: reson@reson.co.za<br />
RESON OFFSHORE LTD. RESON Mediterranean SRL<br />
Scotland, U.K.<br />
Italy<br />
Tel: +44 1224 709 900 Tel: +39-051-572-643<br />
E-mail: sales@reson.co.uk E-mail: info@reson.it<br />
Version: B109 051228 / A4