26.02.2015 Views

RA Case Study.pdf - UltraVision Group

RA Case Study.pdf - UltraVision Group

RA Case Study.pdf - UltraVision Group

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.kerasoft.co.uk<br />

®<br />

History<br />

<strong>RA</strong> Clinical Notes<br />

<strong>RA</strong> is a 30 year old female who developed ectasia following LASIK surgery 7 years previously. Before the<br />

surgery, she was a bilateral -7.00 myope with a spherical prescription with no sign of sub-clinical<br />

keratoconus. One year after the LASIK surgery, she began to develop astigmatism and her vision became<br />

steadily worse until it deteriorated rapidly a year before this consultation. She returned to the laser treatment<br />

company where she was given a diagnosis of post LASIK ectasia and was fitted with RGP contact lenses.<br />

She could not tolerate these at all and was referred for Corneal Cross Linking (CXL), undergoing the<br />

procedure for the right eye in March 2008. After the CXL her Ophthalmologist referred her for contact lens<br />

assessment whilst still monitoring the thickness of the left cornea. She was struggling at work (child care) as<br />

her vision was variable and ghosting was caused by her irregular corneas. She was also finding it difficult to<br />

drive at night due to ghosting and multiple images of lights.<br />

Initial Findings<br />

Vision:<br />

RE: Count Fingers LE: 3/24<br />

Spectacle Rx:<br />

RE: -8.00/-4.50 x 87 VA 6/12<br />

LE: -2.25/-2.50 x 95 VA 6/9 with severe ghosting<br />

Keratometry:<br />

RE: 7.70 x 100/7.02 x 10 LE: 7.09 x 97/6.56 x 7<br />

Topography:<br />

RE<br />

LE<br />

Rationale for KeraSoft ® Fitting<br />

After being diagnosed with post LASIK ectasia, <strong>RA</strong> had tried rigid lenses and felt they were too uncomfortable<br />

to wear. Also they had the tendency to fall out when she moved her eyes rapidly. Additionally, the surgeon<br />

indicated he would prefer her to be fitted with a soft lens option following corneal cross linking surgery. She<br />

therefore wanted to try KeraSoft ® contact lenses.<br />

<strong>UltraVision</strong> International Ltd, Commerce Way, Leighton Buzzard, Beds, LU7 4RW<br />

UK Freephone 0800 585115 or +44 (0)1525 381112<br />

email: info@ultravision.co.uk web: www.ultravisiongroup.com


®<br />

<strong>RA</strong> Clinical Notes Cont’d<br />

Slit Lamp<br />

Right cornea slightly hazy centrally. Patchy punctate staining inferiorly RE and LE.<br />

Initial KeraSoft ® 3 Fitting<br />

RE: 8.60/14.50/-6.00/-3.50 x 87 VA 6/7 LE: 8.60/14.50/-2.00/-2.50 x 110 VA 6/7<br />

<strong>RA</strong> was able to wear the KeraSoft ® 3 lenses all day with excellent comfort.<br />

3 Month Follow Up<br />

Lenses were slightly mobile and vision variable depending on centration. To establish a better centration for<br />

the optical zone, <strong>RA</strong> was refitted with KeraSoft ® IC.<br />

KeraSoft ® IC Fitting<br />

RE: 8.20/15.00/-6.00/-3.00 x 87 VA 6/6 LE: 8.20/15.00/-2.25/-2.50 x 110 VA 6/6<br />

<strong>RA</strong> found the acuity more stable with the new KeraSoft ® IC lenses and continued to wear them all day with<br />

comfort.<br />

1 Year Follow Up<br />

KeraSoft ® IC lenses continued to work well with the same specifications.<br />

Topography<br />

RE<br />

LE<br />

The topographies were now more regular, particularly for the right cornea, and <strong>RA</strong> found she could now wear<br />

disposable contact lenses for swimming.<br />

Summary<br />

Patient with bilateral post LASIK ectasia and right CXL intolerant to RGP lenses<br />

Patient went from:<br />

Poor spectacle acuity of RE: 6/12 and LE: 6/9 with severe ghosting<br />

To:<br />

All day comfortable wear of KeraSoft ® IC lenses with a stable visual acuity of RE: 6/6 and LE: 6/6<br />

<strong>RA</strong> was able to drive at night again and to perform fully with confidence in her child care profession<br />