<strong>MC</strong> Clinical Notes Cont’d<br />

Rationale for KeraSoft ® fitting<br />

<strong>MC</strong> had heard of KeraSoft ® lenses and wished to see if he could achieve sufficient levels of vision to avoid<br />

undergoing corneal graft surgery. He had been informed by his hospital practitioner that no rigid lens type<br />

would offer him sufficient visual acuity to enable him to continue driving.<br />

Topography/Simulated Keratometry readings<br />

RE<br />

LE<br />

Central: 5.44 X 31/4.92 x 121 6.38X 103/6.02 x 13<br />

Flattest: 8.14 7.45<br />

Initial Fitting Lenses<br />

KeraSoft ® IC SiH<br />

RE: 8.20/14.50/STD/-14.00/-4.00 x 45 VA 6/9 LE: 8.20/14.50/STD/-14.00 DS VA 6/6<br />

When the flat fitting RGP lenses were discontinued, it was expected that the cornea would become steeper,<br />

as it went through the demoulding process. The patient was advised that he may require steeper KeraSoft ®<br />

IC lenses to be fitted at subsequent visits as the cornea settled.<br />

<strong>MC</strong> decided to go ahead with the fitting as the improvement in his acuity was better than he had anticipated.<br />

The above KeraSoft ® IC lenses were supplied. After 2 days wear, he reported a significant reduction in<br />

photophobia, a considerable increase in comfort and achieved 18 hours wear comfortably. <strong>MC</strong> kept in<br />

contact during the following weeks and his acuity was regularly checked to ensure he did not fall below the<br />

driving standard whilst his corneal shape fluctuated during the “demoulding from RGP” process.<br />

3 month follow up<br />

Both lenses now appeared tighter than at initial fitting but movement was still acceptable and the left lens<br />

rotated 15 degrees clockwise (CW). <strong>MC</strong> reported vision had reduced slightly but was still better than with his<br />

previous RGP lenses.<br />

Visual Acuity<br />

RE: 6/9 - No over refraction<br />

LE: 6/18 - OR -2.25DS VA 6/7.5 pt<br />