HIGHLIGHTS<br />

• Global Input Power<br />

• True on-line uninterruptible power suplly (UPS)<br />

• Lightweight and rugged design<br />

• User-configurable communications<br />

• Liquid crystal display (LCD)<br />

• Input isolation transformer<br />

• Input power factor correction<br />

• Automatic bypass<br />

• Auxiliary output for printers<br />

• Single-point ground<br />

• MIL-STD-810-F<br />

SPECIFICATIONS<br />

ELECTRICAL<br />

Input voltage<br />

100/120/220/240 VAC (automatically sensed and selected)<br />

Input frequency 40 - 65Hz range; 50/60 Hz auto selection; ±3% Hz sync. range window<br />

Max input current 10 A (at 120 VAC )<br />

Input power factor 0.97 typical<br />

Output rating<br />

1000 VA / 700 W<br />

Output voltage<br />

120 VAC ±2% true sinewave, max 5% total harmonic distortion (THD) fullnon-linear load. (The<br />

UPS output rating should be reduced by 10% for the output voltage setting of 100 VAC)<br />

Output frequency 50 or 60 Hz (fi xed selectable; or synchronized to input)<br />

Transfer time to battery uninterrupted (none)<br />

BATTERY<br />

Reserve time<br />

6 minutes at full load<br />

Recharge time 4 hours to 90%<br />

Quantity and type (3) 12 V / 7.2 ampere hours (Ah), valve regulated, non-spillable, lead acid<br />

ENVIRONMENTAL<br />

Ambient temperature<br />

above sea level,<br />

Relative humidity<br />

Operating altitude<br />

Audible noise<br />

MECHANICAL<br />

Dimensions (H x W x D)<br />

Weight without case<br />

with optional case<br />

Input power cord<br />

Output receptacles<br />

0ºC to 40ºC / 32ºF to 104ºF operating for altitudes 0-3,000 m / 0-10,000 feet<br />

-15ºC to 50ºC / 5ºF to 122ºF non-operating<br />

5% to 95% non-condensing<br />

up to 3,000 m / 10,000 feet at 40ºC / 104ºF, 15,000 m / 50,000 feet non-operating<br />

< 56 dBA at 1 m / 3.3 feet<br />

127 mm x 445 mm x 381 mm / 5 inches x 17.5 inches x 15 inches (without case)<br />

21.8 kg / 48 lbs.<br />

30.4 kg / 67 lbs.<br />

1.8 m / 6 feet, with 5-15P plug<br />

(4) 5-15R (UPS), two (2) 5-15R Aux<br />