GA-540 TADIL-A/LINK-11 SERIAL DATA LINK TRANSLATOR
GA-540 TADIL-A/LINK-11 SERIAL DATA LINK TRANSLATOR
GA-540 TADIL-A/LINK-11 SERIAL DATA LINK TRANSLATOR
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Improving Allied Interoperability<br />
<strong>GA</strong>-<strong>540</strong> <strong>TADIL</strong>-A/<strong>LINK</strong>-<strong>11</strong> <strong>SERIAL</strong> <strong>DATA</strong> <strong>LINK</strong> <strong>TRANSLATOR</strong><br />
The DRS <strong>GA</strong>-<strong>540</strong> <strong>TADIL</strong>-A/<strong>LINK</strong>-<strong>11</strong> Serial Data Link Translator<br />
(SDLT) provides the interface in a <strong>TADIL</strong>/Link-<strong>11</strong> system<br />
between a serial encryption device and a tactical data<br />
system processor. The <strong>GA</strong>-<strong>540</strong> serial interface to the<br />
encryption device meets the Airborne Tactical Data System<br />
(ATDS) interface requirements of MIL-STD-188-203-1A -<br />
Appendix D2. All data buffering, timing and ATDS<br />
handshaking are performed automatically.<br />
System benefits include a simplified system design, flexible<br />
selection of hardware and elimination of costly interface<br />
design. The DRS <strong>GA</strong>-<strong>540</strong> is a proven off-the-shelf system.<br />
The <strong>GA</strong>-<strong>540</strong> is offered as a 19-inch rack-mountable unit, a<br />
1/4 ATR-Short unit, or a 6U-VME card. The rack-mounted and<br />
ATR units include a power supply, built-in-test indicator and<br />
panel-mounted connectors. The VME card set can be hosted<br />
in any VME operating environment.<br />
<strong>GA</strong>-<strong>540</strong> <strong>TADIL</strong>-A/<strong>LINK</strong>-<strong>11</strong> Serial Data Link Translator<br />
The ATDS interface conforms to the requirements of the<br />
standard serial cryptographic device. Data is transmitted<br />
with the appropriate burst of clock pulses in response to<br />
each demand pulse from the Data Terminal Set (DTS). The<br />
re-circulated data is checked on the board and if an error is<br />
detected, an ATDS fault pulse is generated and error status<br />
bits are set. The message status summary bits from the<br />
DTS are passed through along with the received data to the<br />
Tactical Data System.<br />
MX-512P/SDLT<br />
Cleared by US DoD/OSR for Public Release under OSR case number 05-S-0977 dated 04.22.2005.
HIGHLIGHTS<br />
• Meets MIL-STD-188-203-1A<br />
• RS-422/RS-423 conditioned diphase and<br />
synchronous interface<br />
• Transformer-coupled conditioned diphase interface<br />
• RS-423 asynchronous interface<br />
• VME bus interface<br />
<strong>GA</strong>-<strong>540</strong>V - VME CONFIGURATION<br />
Nomenclature<br />
CV-4285(V)<br />
Part Number 33527<br />
Size<br />
6U-VME<br />
Weight<br />
1.1 lbs. (0.5 kg)<br />
Power +5V @ 1.2 A,<br />
+12V @ 10 mA,<br />
-12V @ 35 mA<br />
MTBF in accordance with 120,000 hours<br />
MIL-HDBK-217F at<br />
25ºC fixed<br />
MTTR (organizational level) N/A<br />
MTTR (depot level)<br />
1 hour<br />
Temperature<br />
Operating<br />
-65.2ºF to +131ºF<br />
(-54ºC to +55ºC)<br />
Non-operating<br />
-70.6ºF to +185ºF<br />
(-57ºC to +85ºC)<br />
<strong>GA</strong>-<strong>540</strong>A - AIRBORNE CONFIGURATION<br />
Nomenclature<br />
CV-4284(V)<br />
Part Number 33500<br />
Size<br />
1/4-ATR-Short,<br />
7.6 H x 2.25 W<br />
x 12.6 D inches<br />
(19.30 H x 5.70 W<br />
x 32.00 D cm)<br />
Weight<br />
10 lbs. (4.6 kg)<br />
Power<br />
24 to 32 VDC, 15 W<br />
MTBF in accordance with 78,000 hours<br />
MIL-HDBK-217F at<br />
+77ºF (+25ºC) fixed<br />
MTTR (organizational level) 20 minutes<br />
MTTR (depot level)<br />
1 hour<br />
Temperature<br />
Operating<br />
-65.2ºF to +131ºF<br />
(-54ºC to +55ºC)<br />
Non-operating<br />
-70.6ºF to +185ºF<br />
(-57ºC to +85ºC)<br />
Vibration MIL-E-<strong>540</strong>0T, para 3.2.24.5<br />
Shock MIL-E-<strong>540</strong>0T, para 3.2.24.6<br />
Humidity 95%<br />
<strong>GA</strong>-<strong>540</strong>R - RACK-MOUNT CONFIGURATION<br />
Part Number 33500<br />
Size<br />
1/4-ATR-Short,<br />
1.75 H x 17.5 W x 12 D<br />
inches<br />
(4.4 H x 48.3 W<br />
x 30.5 D cm)<br />
Weight<br />
5 lbs. (2.3 kg)<br />
Power<br />
85 to 264 VAC,<br />
47 to 440 Hz, 15 W<br />
MTBF in accordance with 61,000 hours<br />
MIL-HDBK-217F at<br />
+77ºF (+25ºC) fixed<br />
MTTR (organizational level) 20 minutes<br />
MTTR (depot level)<br />
1 hour<br />
Temperature<br />
Operating<br />
+32ºF to +122ºF<br />
(0ºC to +50ºC)<br />
Non-operating<br />
-4ºF to +158ºF<br />
(-20ºC to +70ºC)<br />
Vibration<br />
Commercial equipment<br />
environment<br />
Shock<br />
Commercial equipment<br />
environment<br />
Humidity<br />
Commercial equipment<br />
environment<br />
Specifications subject to change without notice. Copyright © DRS ICAS, LLC 2013. All Rights Reserved.<br />
Export of DRS ICAS, LLC products may be subject to U.S. Export Controls. U.S. Export licenses may be required.<br />
DRS ICAS, LLC.<br />
2601 Mission Point Blvd., Suite 250 Beavercreek, OH 45431 Tel: 937.429.7408 Fax 937.429.7176 www.drs.com marketing@drs.com<br />
Cleared for Public Release – DRS FSO Dated 03 June 2013.<br />
DRS HOR V8 06/03/13