<strong>IMPORTANT</strong> <strong>SAFETY</strong> <strong>INSTRUCTIONS</strong><br />
<strong>SAFETY</strong> <strong>INSTRUCTIONS</strong><br />
Please read all these instructions carefully prior to using the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system and<br />
the E-nozzle. The E-nozzle should only be used with the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system for the purposes<br />
described in this operating manual.<br />
year<br />
guarantee<br />
1. Always pull out the mains power plug prior to dismantling the E-nozzle/<strong>Pro</strong>-<strong>Aqua</strong> room cleaning<br />
system for care.<br />
2. The E-nozzle/<strong>Pro</strong>-<strong>Aqua</strong> room cleaning system should always be supervised during use. Children<br />
and persons unfamiliar with operation of the appliance should be kept away from the <strong>Pro</strong>-<strong>Aqua</strong>.<br />
3. Never vacuum fl ammable liquids!<br />
4. Avoid vacuuming of hard objects or objects with sharp edges.<br />
5. Do not vacuum cigarettes, matches, ash and/or other smoking or burning objects.<br />
6. Never use the E-nozzle/<strong>Pro</strong>-<strong>Aqua</strong> room cleaning system with a damaged mains power cable.<br />
7. Never switch off the E-nozzle/<strong>Pro</strong>-<strong>Aqua</strong> room cleaning system with a connected mains cable.<br />
Always pull out the mains plug if the unit is not used for a long period and for maintenance work.<br />
Pull the plug out of the socket and switch off all control elements.<br />
8. Heed the manufacturer’s instructions for use and warnings and only use approved original<br />
accessories.<br />
9. The electrical nozzle should not be exposed to moisture to avoid the risk of electric shock.<br />
Do not use the electrical nozzle outdoors or on damp ground. The electrical nozzle should not<br />
be immersed in water. Always switch off the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system cleaning before<br />
attaching and detaching the electrical brush.<br />
10. Check the electrical hose regularly.<br />
11. Contact the manufacturer if the mains cable is damaged.<br />
12. The manufacturer bears no liability for damage resulting from incorrect use or use contrary to<br />
instructions, unilateral repairs or incorrect maintenance.<br />
10-06<br />
E-nozzles<br />
operating manual
INTEGRAL COMPONENTS<br />
COMPONENTS<br />
BASIC FUNCTIONS<br />
FUNCTIONS<br />
CARE<br />
Direct contact<br />
equipment variant<br />
1. Electrical nozzle (only suitable for dry vacuuming)<br />
2. Telescopic wand for electrical nozzle, stainless steel<br />
3. <strong>Pro</strong>-<strong>Aqua</strong> electrical hose (two colours), only suitable for dry vacuuming<br />
Use of electrical nozzle<br />
The <strong>Pro</strong>-<strong>Aqua</strong> electrical nozzle is particularly suitable for cleaning heavily-used rugs and carpets, but<br />
also upholstery and mattresses.<br />
The <strong>Pro</strong>-<strong>Aqua</strong> electrical nozzle can also be used for vacuuming hard fl oors.<br />
Switch off your <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system. Insert the electrical hose cable in the connection<br />
provided (see integral components).<br />
Switch on the <strong>Pro</strong>-<strong>Aqua</strong>. Actuate the unlocking mechanism (A) and move the telescopic wand to the<br />
slanted position (B). The motor now starts automatically. The motor switches off if the telescopic<br />
wand is moved back to a vertical position.<br />
Electrical nozzle overload protection<br />
A resetable overload fuse automatically deactivates the motor for its own safety if overloading occurs<br />
as a result of blocking of the brush roller, bulky foreign bodies or knotting of carpet fringes.<br />
The red warning lamp is illuminated as a result. In cases where this occurs, please proceed<br />
as follows:<br />
• Switch off the electrical nozzle and pull the mains plug of the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system<br />
out of the socket.<br />
• Remedy the cause of the error, clean the brush roller if necessary.<br />
• Press the reset button (red) on the rear of the suction nozzle.<br />
You can then restart the appliance.<br />
WARNING<br />
Dry vacuuming only!<br />
CARE OF ELECTRICAL NOZZLE<br />
1. Pull the nozzle mains plug out.<br />
2. Remove any deposits of hair and carpet<br />
fi bres with the crevice nozzle.<br />
TECHNICAL DATA<br />
DATA<br />
Voltage:<br />
Power output:<br />
Patent number<br />
230 V – 50 Hz<br />
150 Watt<br />
INTEGRAL COMPONENTS<br />
COMPONENTS<br />
1. Electrical nozzle (only suitable for dry vacuuming)<br />
2. Telescopic wand for electrical nozzle, stainless steel<br />
3. <strong>Pro</strong>-<strong>Aqua</strong> electrical hose (two colours),<br />
only suitable for dry vacuuming<br />
BASIC FUNCTIONS<br />
FUNCTIONS<br />
Use of electrical nozzle<br />
Young Family<br />
equipment variant<br />
The <strong>Pro</strong>-<strong>Aqua</strong> electrical nozzle is particularly suitable for cleaning heavily-used rugs and carpets, but<br />
also upholstery and mattresses.<br />
The <strong>Pro</strong>-<strong>Aqua</strong> electrical nozzle can also be used for vacuuming hard fl oors.<br />
Switch off your <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system. Insert the electrical hose cable in the connection<br />
provided (see integral components).<br />
Switch on the <strong>Pro</strong>-<strong>Aqua</strong>. Actuate the unlocking mechanism (A) and move the telescopic wand to the<br />
slanted position (B). The motor now starts automatically. The motor switches off if the telescopic<br />
wand is moved back to a vertical position.<br />
Electrical nozzle overload protection<br />
The motor no longer runs at top speed if overloading of the motor occurs as a result of blocking of<br />
the brush roller, bulky foreign bodies or knotting of carpet fringes.<br />
In cases where this occurs, please proceed as follows:<br />
• Switch off the electrical nozzle and pull the mains plug of the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system<br />
out of the socket.<br />
• Remedy the cause of the error, clean the brush roller if necessary.<br />
• You can then restart the appliance.<br />
CARE<br />
CARE OF ELECTRICAL NOZZLE<br />
1. Pull the nozzle mains plug out.<br />
2. Remove any deposits of hair and carpet<br />
fi bres with the crevice nozzle.<br />
Environmental protection instructions:<br />
Patent number<br />
TECHNICAL DATA<br />
DATA<br />
Voltage:<br />
Power output:<br />
WARNING<br />
Dry vacuuming only!<br />
230 V – 50 Hz<br />
130 Watt<br />
This product should not be disposed of in normal household waste at the end of its service life. It should be taken to a collection<br />
point for recycling electrical and electronic appliances. Materials can be recycled in accordance with their markings.<br />
You are making an important contribution to environmental protection through reuse, material recycling or other forms of<br />
recycling of old appliances. Please ask the local authorities for information on your nearest disposal site.