Please read all these instructions carefully prior to using the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system and<br />

the E-nozzle. The E-nozzle should only be used with the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system for the purposes<br />

described in this operating manual.<br />

year<br />

guarantee<br />

1. Always pull out the mains power plug prior to dismantling the E-nozzle/<strong>Pro</strong>-<strong>Aqua</strong> room cleaning<br />

system for care.<br />

2. The E-nozzle/<strong>Pro</strong>-<strong>Aqua</strong> room cleaning system should always be supervised during use. Children<br />

and persons unfamiliar with operation of the appliance should be kept away from the <strong>Pro</strong>-<strong>Aqua</strong>.<br />

3. Never vacuum fl ammable liquids!<br />

4. Avoid vacuuming of hard objects or objects with sharp edges.<br />

5. Do not vacuum cigarettes, matches, ash and/or other smoking or burning objects.<br />

6. Never use the E-nozzle/<strong>Pro</strong>-<strong>Aqua</strong> room cleaning system with a damaged mains power cable.<br />

7. Never switch off the E-nozzle/<strong>Pro</strong>-<strong>Aqua</strong> room cleaning system with a connected mains cable.<br />

Always pull out the mains plug if the unit is not used for a long period and for maintenance work.<br />

Pull the plug out of the socket and switch off all control elements.<br />

8. Heed the manufacturer’s instructions for use and warnings and only use approved original<br />

accessories.<br />

9. The electrical nozzle should not be exposed to moisture to avoid the risk of electric shock.<br />

Do not use the electrical nozzle outdoors or on damp ground. The electrical nozzle should not<br />

be immersed in water. Always switch off the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system cleaning before<br />

attaching and detaching the electrical brush.<br />

10. Check the electrical hose regularly.<br />

11. Contact the manufacturer if the mains cable is damaged.<br />

12. The manufacturer bears no liability for damage resulting from incorrect use or use contrary to<br />

instructions, unilateral repairs or incorrect maintenance.<br />

10-06<br />

E-nozzles<br />

operating manual


INTEGRAL COMPONENTS<br />

COMPONENTS<br />

BASIC FUNCTIONS<br />

FUNCTIONS<br />

CARE<br />

Direct contact<br />

equipment variant<br />

1. Electrical nozzle (only suitable for dry vacuuming)<br />

2. Telescopic wand for electrical nozzle, stainless steel<br />

3. <strong>Pro</strong>-<strong>Aqua</strong> electrical hose (two colours), only suitable for dry vacuuming<br />

Use of electrical nozzle<br />

The <strong>Pro</strong>-<strong>Aqua</strong> electrical nozzle is particularly suitable for cleaning heavily-used rugs and carpets, but<br />

also upholstery and mattresses.<br />

The <strong>Pro</strong>-<strong>Aqua</strong> electrical nozzle can also be used for vacuuming hard fl oors.<br />

Switch off your <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system. Insert the electrical hose cable in the connection<br />

provided (see integral components).<br />

Switch on the <strong>Pro</strong>-<strong>Aqua</strong>. Actuate the unlocking mechanism (A) and move the telescopic wand to the<br />

slanted position (B). The motor now starts automatically. The motor switches off if the telescopic<br />

wand is moved back to a vertical position.<br />

Electrical nozzle overload protection<br />

A resetable overload fuse automatically deactivates the motor for its own safety if overloading occurs<br />

as a result of blocking of the brush roller, bulky foreign bodies or knotting of carpet fringes.<br />

The red warning lamp is illuminated as a result. In cases where this occurs, please proceed<br />

as follows:<br />

• Switch off the electrical nozzle and pull the mains plug of the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system<br />

out of the socket.<br />

• Remedy the cause of the error, clean the brush roller if necessary.<br />

• Press the reset button (red) on the rear of the suction nozzle.<br />

You can then restart the appliance.<br />

WARNING<br />

Dry vacuuming only!<br />

CARE OF ELECTRICAL NOZZLE<br />

1. Pull the nozzle mains plug out.<br />

2. Remove any deposits of hair and carpet<br />

fi bres with the crevice nozzle.<br />

TECHNICAL DATA<br />

DATA<br />

Voltage:<br />

Power output:<br />

Patent number<br />

230 V – 50 Hz<br />

150 Watt<br />

INTEGRAL COMPONENTS<br />

COMPONENTS<br />

1. Electrical nozzle (only suitable for dry vacuuming)<br />

2. Telescopic wand for electrical nozzle, stainless steel<br />

3. <strong>Pro</strong>-<strong>Aqua</strong> electrical hose (two colours),<br />

only suitable for dry vacuuming<br />

BASIC FUNCTIONS<br />

FUNCTIONS<br />

Use of electrical nozzle<br />

Young Family<br />

equipment variant<br />

The <strong>Pro</strong>-<strong>Aqua</strong> electrical nozzle is particularly suitable for cleaning heavily-used rugs and carpets, but<br />

also upholstery and mattresses.<br />

The <strong>Pro</strong>-<strong>Aqua</strong> electrical nozzle can also be used for vacuuming hard fl oors.<br />

Switch off your <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system. Insert the electrical hose cable in the connection<br />

provided (see integral components).<br />

Switch on the <strong>Pro</strong>-<strong>Aqua</strong>. Actuate the unlocking mechanism (A) and move the telescopic wand to the<br />

slanted position (B). The motor now starts automatically. The motor switches off if the telescopic<br />

wand is moved back to a vertical position.<br />

Electrical nozzle overload protection<br />

The motor no longer runs at top speed if overloading of the motor occurs as a result of blocking of<br />

the brush roller, bulky foreign bodies or knotting of carpet fringes.<br />

In cases where this occurs, please proceed as follows:<br />

• Switch off the electrical nozzle and pull the mains plug of the <strong>Pro</strong>-<strong>Aqua</strong> room cleaning system<br />

out of the socket.<br />

• Remedy the cause of the error, clean the brush roller if necessary.<br />

• You can then restart the appliance.<br />

CARE<br />

CARE OF ELECTRICAL NOZZLE<br />

1. Pull the nozzle mains plug out.<br />

2. Remove any deposits of hair and carpet<br />

fi bres with the crevice nozzle.<br />

Environmental protection instructions:<br />

Patent number<br />

TECHNICAL DATA<br />

DATA<br />

Voltage:<br />

Power output:<br />

WARNING<br />

Dry vacuuming only!<br />

230 V – 50 Hz<br />

130 Watt<br />

This product should not be disposed of in normal household waste at the end of its service life. It should be taken to a collection<br />

point for recycling electrical and electronic appliances. Materials can be recycled in accordance with their markings.<br />

You are making an important contribution to environmental protection through reuse, material recycling or other forms of<br />

recycling of old appliances. Please ask the local authorities for information on your nearest disposal site.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!