Problem<br />
The boiler starts heating the home or the tap water at night<br />
even though the controller is set low.<br />
Solution<br />
- Weather-compensated control (OTC) means that the boiler is controlled<br />
by the outside temperature. This can be prevented by adjusting the Heat<br />
limit night or selecting another control strategy. See the installation<br />
and service manual.<br />
EN<br />
- The boiler can start pre-heating before the following set point. Adjust the<br />
Max. pre-heating time setting (see the installation and service manual).<br />
The home may well not be up to temperature on time as a result.<br />
- The tap water is only heated when the room temperature set is higher than<br />
the night temperature. See the installation and service manual for details<br />
of how to change the night temperature.<br />
T001024-06-A<br />