Crime & Criminals Tracking Network and Systems Project<br />

<strong>Meghalaya</strong> <strong>Police</strong><br />

Sl<br />

No<br />

Specification<br />

pr<strong>of</strong>ile based on security best practices<br />

• Top alerts and alert history: Should support<br />

In<strong>for</strong>mation about the key alerts impacting<br />

their environment (with the ability to drill<br />

down into more in<strong>for</strong>mation), along with the<br />

history <strong>of</strong> alerts over time<br />

• It should be capable <strong>of</strong> providing customized<br />

alerts based on incidents and assets<br />

Complied<br />

(Y/N)<br />

Reference<br />

to Data<br />

Sheet<br />

Value Add (If<br />

any)/<br />

Remarks<br />

Specification-cum-Compliance Sheet <strong>for</strong> Line Interactive UPS - 2 KVA with 120 min back up<br />

Sl<br />

No<br />

Specification<br />

1 Type : Line-interactive<br />

2 Capacity: 2 KVA/10 KVA as per the Bill <strong>of</strong> Material<br />

3 Back up: 120 minutes as per the Bill <strong>of</strong> Material<br />

4 Input <strong>Vol</strong>tage Range: 140 – 280 V AC<br />

5 Input Frequency: 50 Hz +/‐10%<br />

6 Output <strong>Vol</strong>tage: 220 V +/‐ 10%<br />

7<br />

Output Frequency: 50 Hz +/‐ 0.5 Hz (under battery<br />

mode)<br />

8 Noise: < 40 db at 1 m<br />

9 Protection: Low Battery, Overcharge<br />

10 AVR: Built in Automatic <strong>Vol</strong>tage Regulator (AVR)<br />

11<br />

12<br />

13<br />

14<br />

Indicators: LED indicators <strong>for</strong> AC Mains, DC, Load<br />

on Mains/Battery<br />

Battery Type & back‐up time: Batteries shall be<br />

inbuilt Sealed Maintenance Free (SMF) type. The<br />

system must be capable <strong>of</strong> providing 30 minutes<br />

battery back-up time as per VAH rating below :<br />

(Minimum VAH <strong>for</strong> 30 minutes back‐up = 504 VAH)<br />

Total number <strong>of</strong> batteries, <strong>Vol</strong>tage <strong>of</strong> each battery,<br />

Ampere-Hour rating <strong>of</strong> each battery <strong>of</strong>fered to be<br />

specified.<br />

Ambient Conditions: Temperature: 0 to 40 deg Celsius<br />

Humidity: upto 95%<br />

Quality Certification: UPS OEM should be ISO<br />

9001:2008 certified<br />

Complied<br />

(Y/N)<br />

Reference<br />

to Data<br />

Sheet<br />

Value Add (If<br />

any)/<br />

Remarks<br />

Specification-cum-Compliance Sheet <strong>for</strong> Duplex laser printer<br />

Sl<br />

No<br />

Specification<br />

1 Print technology: Monochrome Laser<br />

2 Print speed: > 15 ppm<br />

3 Processor speed: 266 MHz<br />

4 Print Resolution: Up to 1200 x 1200 dpi<br />

5 Duty cycle (monthly, A4): > 5000 copies<br />

Media types supported: Plain paper, envelopes,<br />

6<br />

transparencies, cardstock, postcards, labels<br />

Complied<br />

(Y/N)<br />

Reference to<br />

Data Sheet<br />

Value Add (If<br />

any)/<br />

Remarks<br />

<strong>Vol</strong>ume I Request <strong>for</strong> Proposal <strong>for</strong> Selection <strong>of</strong> System Integrator Page 195 <strong>of</strong> 205