L-850D/E Style 2 F-Range Series FAA Runway Threshold ...
L-850D/E Style 2 F-Range Series FAA Runway Threshold ...
L-850D/E Style 2 F-Range Series FAA Runway Threshold ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
F-<strong>Range</strong> Type L-<strong>850D</strong>/E <strong>Style</strong> 2 Inset Lights Installation<br />
1. See Figure 3-2. Clean the contact surfaces of the base receptacle.<br />
Make sure that the base receptacle does not contain water and is<br />
completely clean and dry. The mating surfaces must be clean and free<br />
of foreign particles.<br />
NOTE: When installing fixture on an L-868B extension meeting AC<br />
150/5345-42F, the minimum extension height must be 4.50<br />
inches. Option is to order an extension with a 10 inch ID then any<br />
height extension can be used.<br />
Figure 3-2 Installation on L-868B Light Base<br />
1. Light Assembly 4. Rubber Grommet 7. Isolation Transformer 10. Screw, 3/8-16<br />
2. <strong>FAA</strong> Deep Base 5. Conduit 8. Ground Lug<br />
3. Secondary Connectors 6. Spacer 9. Primary Connector<br />
© 2009 ADB Airfield Solutions, LLC. 96A0308E Page 3-3<br />
All rights reserved Issued 4/03