Measurement techniques for large aspheric optics - LOFT, Large ...
Measurement techniques for large aspheric optics - LOFT, Large ...
Measurement techniques for large aspheric optics - LOFT, Large ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Comparison of Fizeau, SOC<br />
<strong>for</strong> 1.4-m diameter off-axis aspheres<br />
• The Fizeau test was budgeted as < 3.3 nm rms uncertainty, after<br />
correction <strong>for</strong> low order terms.<br />
• SOC measurements of the OAPs are consistent with this.<br />
Fizeau<br />
SOC<br />
Raw data<br />
Astigmatism and coma from<br />
alignment were not needed to be<br />
controlled accurately<br />
109 nm rms 117 nm rms<br />
Difference<br />
After<br />
removing low<br />
order terms<br />
14 nm rms 16 nm rms 7 nm rms<br />
<strong>Large</strong>st errors in Fizeau came from<br />
coating defect on <strong>large</strong> fold flat 1 nm rms<br />
ghost fringes 1 nm rms<br />
J. H. Burge University of Arizona 44