Intermittent Pilot Checkout Procedure<br />

• Turn on main gas supply<br />

• Turn on manual gas valve<br />

• Turn on electrical power<br />

• Set thermostat to call for heat, spark begins<br />

ROBERTSHAW 780-745<br />

IGN<br />

FLAME<br />

SENSE<br />

PV<br />

GRD<br />

TR<br />

PV/MV<br />

TH<br />

MV<br />

Ignition<br />

Control<br />

Module<br />

U<br />

<strong>Valve</strong> Operator<br />

Terminals<br />

M C P<br />

Transformer<br />

24 VAC<br />

120 VAC<br />

High<br />

Limit<br />

NC<br />

Fan Control NO<br />

• Air purged from gas line<br />

Pilot Line ⇒<br />

Pilot and<br />

Electrode /<br />

Sensor<br />

Fan<br />

Motor<br />

• Pilot Ignition - main burner ignition<br />

• Turn manual gas valve off - burner & pilot go out<br />

• Sparking begins - turn manual valve on<br />

• Pilot ignites - main burner ignites