Troubleshooting Tips<br />

Problem # 4: Main Burner Does Not Shut Off When Thermostat<br />

is Satisfied<br />

Possible Causes:<br />

• Faulty <strong>Gas</strong> <strong>Valve</strong><br />

• Faulty Ignition Control<br />

Troubleshooting:<br />

• Check thermostat to make sure contacts are open, check for 24 Volts<br />

between “TH” and “TR”.<br />

– Should be Zero, if gas valve is stuck open, replace valve<br />

• Check for 24 Volts between “PV/MV” and “GND” .<br />

– If 24 Volts present, replace ignition control<br />

– If 24 Volts not present, replace gas valve