<strong>485HF9</strong><br />

RS485/422 to RS232 Converter<br />

RS485/RS422 to RS232 Converter<br />

Model <strong>485HF9</strong><br />

- Industry standard serial converters<br />

- UK designed and manufactured<br />

- Automatic turnaround feature on MA485F9<br />

- Automatic data rate detection<br />

- 485 Screw terminal connectors for easy wiring<br />

- Selectable 120 Ohm termination resistor<br />

- Optional DC power supply 9-12 V


Technical Data<br />

Model <strong>485HF9</strong><br />

depress<br />

to<br />

change<br />

Logic input<br />

0<br />

Net<br />

Logic output<br />

1 2 3<br />

1 2 3<br />

Digital Amplifier + Setpoint<br />

DAS 72.1 Mark III<br />

1<br />

0 T<br />

2<br />

SET UP<br />

1.Zero 2.Span 3.Display 4.Filter 5.CLout 6.Input 1/2/3 7.Outp. 1/2/3 8.Data<strong>com</strong>.<br />

1.0/allow>0< 1.Set cal ´n´ 1.o/u limits ´n´ 1.fcut Hz 1.4mA=´n´ 1.Assign Key 1.SPoint´n´ 1.Baud rate<br />

2.Calibrate 2.Calibrate 2.Step*´n´ 2.Algorithm 2.20mA=´n´ 2.<br />

2.Hyst. ±´n´ 2.422/485<br />

3.Set mV/V 3.Set mV/V 3.Dec.point 3.Update rate 3.Base 3.<br />

3.Base 3.Address<br />

4.Disp.mV/V 4.Logic stats 4.Motion´n´ 4.Test I mA 4.Test 4.Test 4.Auto trnsm.<br />

Load cell 5Vdc < 80mA CL out RS422/485<br />

Isolated<br />

Logic Outputs<br />

Isolated<br />

Logic Inputs<br />

Isolated<br />

Power 11 -25Vdc<br />

Exc Sen Inp Inp Sen Exc 0-20mA Rx Rx Tx Tx<br />

1 2 3 <strong>com</strong> 1 2 3 <strong>com</strong><br />

+ + + - - - Io Gnd + - + -<br />

+ + 0 0<br />

T<br />

3<br />

4<br />

Model <strong>485HF9</strong> Non-isolated<br />

This model provides basic electrical signal level<br />

conversion from RS232 to RS422 or 4 wire RS485.<br />

For 2 wire RS485 applications we would re<strong>com</strong>mend<br />

using the MA<strong>485HF9</strong> below. Maximum baud rate 1<br />

Mbps. A suitable external power supply is available<br />

separately.<br />

0 VDC<br />

+12 VDC<br />

External PSU available separately<br />

Not Connected<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

-EN<br />

GND<br />

B<br />

A<br />

A’<br />

B’<br />

GND<br />

8 VDC<br />

MODEL<br />

<strong>485HF9</strong>CE<br />

To RS232 Port<br />

on Computer<br />

Model MA485H9 Non-isolated<br />

The ‘Magic’ converter features an automatic line turnaround facility allowing full duplex RS232 connections to<br />

connect directly to a half duplex 2 wire RS485 bus without a requirement for software based transmission<br />

control. Maximum baud rate 115 kbps. A suitable external power supply is available separately.<br />

depress<br />

to<br />

change<br />

Logic input<br />

0<br />

Net<br />

Logic output<br />

1 2 3<br />

1 2 3<br />

Digital Amplifier + Setpoint<br />

DAS 72.1 Mark II<br />

1<br />

0 T<br />

2<br />

T<br />

3<br />

SET UP<br />

4<br />

depress<br />

to<br />

change<br />

Logic input<br />

0<br />

Net<br />

Logic output<br />

1 2 3<br />

1 2 3<br />

Digital Amplifier + Setpoint<br />

DAS 72.1 Mark II<br />

1<br />

0 T<br />

2<br />

T<br />

3<br />

SET UP<br />

4<br />

1.Zero 2.Span 3.Display 4.Filter 5.CLout 6.Input 1/2/3 7.Outp. 1/2/3 8.Data<strong>com</strong>.<br />

1.0/allow>0< 1.Set cal ´n´ 1.o/u limits ´n´ 1.fcut Hz 1.4mA=´n´ 1.Assign Key 1.SPoint´n´ 1.Baud rate<br />

2.Calibrate 2.Calibrate 2.Step*´n´ 2.Algorithm 2.20mA=´n´ 2.<br />

2.Hyst. ±´n´ 2.422/485<br />

3.Set mV/V 3.Set mV/V 3.Dec.point 3.Update rate 3.Base 3.<br />

3.Base 3.Address<br />

4.Disp.mV/V 4.Logic stats 4.Motion´n´ 4.Test I mA 4.Test 4.Test 4.Auto trns.<br />

Load cell 5Vdc < 80mA CL out RS422/485<br />

Isolated<br />

Logic Outputs<br />

Isolated<br />

Logic Inputs<br />

Isolated<br />

Power 11 -25Vdc<br />

Exc Sen Sig Sig Sen Exc 0-20mA Rx Rx Tx Tx<br />

1 2 3 <strong>com</strong> 1 2 3 <strong>com</strong><br />

+ + + - - - Io Gnd + - + -<br />

+ + 0 0<br />

1.Zero 2.Span 3.Display 4.Filter 5.CLout 6.Input 1/2/3 7.Outp. 1/2/3 8.Data<strong>com</strong>.<br />

1.0/allow>0< 1.Set cal ´n´ 1.o/u limits ´n´ 1.fcut Hz 1.4mA=´n´ 1.Assign Key 1.SPoint´n´ 1.Baud rate<br />

2.Calibrate 2.Calibrate 2.Step*´n´ 2.Algorithm 2.20mA=´n´ 2.<br />

2.Hyst. ±´n´ 2.422/485<br />

3.Set mV/V 3.Set mV/V 3.Dec.point 3.Update rate 3.Base 3.<br />

3.Base 3.Address<br />

4.Disp.mV/V 4.Logic stats 4.Motion´n´ 4.Test I mA 4.Test 4.Test 4.Auto trns.<br />

Load cell 5Vdc < 80mA CL out RS422/485<br />

Isolated<br />

Logic Outputs<br />

Isolated<br />

Logic Inputs<br />

Isolated<br />

Power 11 -25Vdc<br />

Exc Sen Sig Sig Sen Exc 0-20mA Rx Rx Tx Tx<br />

1 2 3 <strong>com</strong> 1 2 3 <strong>com</strong><br />

+ + + - - - Io Gnd + - + -<br />

+ + 0 0<br />

120 Ohm Termination<br />

Resistor - Only fitted<br />

to the last device on<br />

the bus.<br />

+12 VDC<br />

0 VDC<br />

Set DAS72.1 Menu 8.2 to<br />

RS485 on all units<br />

1.2 KOhm Network<br />

Biasing resistors<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

GND<br />

B<br />

A<br />

A’<br />

B’<br />

VDC<br />

GND<br />

To RS232 Port<br />

on Computer<br />

CE<br />

MODEL<br />

Magic 485F9<br />

RS232 connector<br />

RS485 connector<br />

Supply voltage<br />

Power connector<br />

Operating current<br />

Data rate<br />

DB9 female<br />

Screw terminal<br />

9 to 12Vdc<br />

Screw terminal<br />

100mA maximum<br />

115.2kbps (1Mbps on <strong>485HF9</strong>)<br />

Operating temperature 0 to +60°C<br />

Storage temperature -20 to +70°C<br />

Dimensions 67 x 43 x 20mm (67 x 53 x 20mm Magic 485)<br />

Weight<br />

60g<br />

DS-<strong>485HF9</strong>-1, 05/09<br />

Tel. +44 (0)1446 771185 Fax +44 (0)1446 771186<br />

Precision Load Cells<br />

Accessories and Mountings<br />

Measuring Instruments and Systems