01.04.2015 Views

FCD-2L - RAD Data Communications

FCD-2L - RAD Data Communications

FCD-2L - RAD Data Communications

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>FCD</strong>-<strong>2L</strong><br />

E1 or Fractional E1 Access Unit<br />

FEATURES<br />

• E1 or Fractional E1 access<br />

unit with one digital data<br />

port<br />

• Selectable synchronous data<br />

rates of n × 64 kbps or<br />

n × 56 kbps, up to<br />

1984 kbps<br />

• V.35, RS-530, V.36/RS-449,<br />

X.21 synchronous data<br />

interfaces<br />

• Optional high-performance<br />

built-in Ethernet bridge, with<br />

or without VLAN support<br />

• Framing format: 2 or<br />

16 frames per multiframe,<br />

with or without CRC-4, or<br />

unframed over E1<br />

• E1 interface complies with:<br />

ITU G.703, G.704, G.732,<br />

G.823, G.706<br />

• E1 link available with or<br />

without LTU


<strong>FCD</strong>-<strong>2L</strong><br />

E1 or Fractional E1 Access Unit<br />

DESCRIPTION<br />

• <strong>FCD</strong>-<strong>2L</strong> is a single-port access unit<br />

for E1 or Fractional E1 services.<br />

<strong>Data</strong> port rates are selectable for<br />

any multiple of 64 or 56 kbps, up<br />

to 1984 kbps. User data is placed<br />

into an E1 frame using only the<br />

required number of timeslots.<br />

• <strong>FCD</strong>-<strong>2L</strong> is available with or<br />

without an LTU (Line Termination<br />

Unit). This allows connection<br />

directly to the service provider’s<br />

line or, alternatively, via an<br />

integral LTU ensuring a range of<br />

up to 2 km (1.2 mi).<br />

• The E1 interface of <strong>FCD</strong>-<strong>2L</strong> is<br />

compatible with virtually all<br />

carrier-provided E1 services and<br />

meets the requirements of ITU<br />

recommendations G.703, G.704,<br />

G.706, and G.732. It supports<br />

either 2 or 16 frames per<br />

multiframe, with or without<br />

CRC-4, as well as unframed data<br />

streams. Line coding is HDB3.<br />

• <strong>FCD</strong>-<strong>2L</strong> can also be used as a rate<br />

and interface converter between<br />

the user data port interface and<br />

E1 (G.703, G.704) lines.<br />

• <strong>FCD</strong>-<strong>2L</strong> has a single user port,<br />

which can be a synchronous data<br />

port with V.35, RS-530,<br />

V.36/RS-449 or X.21 interface, or<br />

a single LAN port with built-in<br />

bridge.<br />

• The synchronous data ports can<br />

operate in the following clock<br />

modes:<br />

• DCE: <strong>FCD</strong>-<strong>2L</strong> provides both<br />

transmit and receive clocks to<br />

the connected user equipment,<br />

with optional sampling of the<br />

incoming data with an inverted<br />

clock<br />

• DTE1: <strong>FCD</strong>-<strong>2L</strong> provides the<br />

transmit clock; connected user<br />

equipment provides the receive<br />

clock<br />

• DTE2: connected user<br />

equipment provides both<br />

transmit and receive clocks to<br />

<strong>FCD</strong>-<strong>2L</strong>.<br />

• When equipped with optional<br />

IR-ETH or IR-ETH/Q bridge,<br />

<strong>FCD</strong>-<strong>2L</strong> can transparently connect<br />

remote LANs over unframed E1<br />

links, utilizing the full E1<br />

bandwidth. It filters Ethernet<br />

frames, forwarding only the<br />

frames destined to the WAN. The<br />

IR-ETH/Q Ethernet port also<br />

supports VLANs.<br />

• The LAN ports are available with a<br />

10BaseT (UTP) Ethernet interface.<br />

The ports operate in full-duplex<br />

mode.<br />

• Timeslot assignment is according<br />

to the data port speed and is<br />

consecutive, starting from any<br />

timeslot.<br />

• The E1 link timing may be taken<br />

from the recovered receive clock<br />

(LBT) or from an internal<br />

oscillator.<br />

• <strong>FCD</strong>-<strong>2L</strong> is set up and controlled<br />

by internal jumpers. Front-panel<br />

switches control all diagnostic<br />

options.<br />

• Diagnostic capabilities include<br />

user-activated local loopbacks on<br />

the E1 link and on the digital data<br />

port. The data port can respond to<br />

an inband ANSI FT1 loop code<br />

that can be generated from the<br />

remote <strong>FCD</strong>-<strong>2L</strong> data port. A<br />

pseudo-random data pattern<br />

(BERT) can be activated and<br />

detected on the data channel.<br />

• The <strong>FCD</strong>-<strong>2L</strong> front panel can<br />

display Major and Minor alarms.<br />

<strong>FCD</strong>-<strong>2L</strong> also has a high Bit Error<br />

Rate (BER) indicator, which lights<br />

when the BER on the E1 line is<br />

higher than 1 x 10 -3 .<br />

• <strong>FCD</strong>-<strong>2L</strong> is available as a<br />

standalone unit or as a card for<br />

the 19-inch rack mount enclosure,<br />

ASM-MN-214. A rack-mount<br />

adaptor kit (RM-9) enables<br />

installation of one or two<br />

standalone units in a 19-inch rack.<br />

APPLICATION


<strong>FCD</strong>-<strong>2L</strong><br />

E1 or Fractional E1 Access Unit<br />

SPECIFICATIONS<br />

E1 PORT (NETWORK)<br />

• Framing<br />

256N (no MF, CCS)<br />

256N (no MF, CCS) with CRC-4<br />

256S (TS16 MF, CAS)<br />

256S (TS16 MF, CAS) with CRC-4<br />

Unframed mode<br />

• <strong>Data</strong> Rate<br />

2.048 Mbps<br />

• Line Code<br />

HDB3<br />

• Impedance<br />

Balanced: 120Ω<br />

Unbalanced: 75Ω<br />

• Signal Level<br />

Receive:<br />

0 to -36 dB with LTU<br />

0 to -10 dB without LTU<br />

Transmit:<br />

Balanced: 3V (±10%)<br />

Unbalanced: 2.37V (±10%)<br />

• Jitter Performance<br />

As per ITU G.823<br />

• Connector<br />

Balanced: RJ-45, 8-pin<br />

Unbalanced: pair of BNC coaxial<br />

• Transmit Timing<br />

Internal clock: ±30 ppm<br />

Loopback timing: ±130 ppm<br />

• Timeslot Allocation<br />

Consecutive (bundled) starting<br />

from any timeslot<br />

• Compliance<br />

ITU G.703, G.704, G.706, G.732<br />

SYNC DATA PORT<br />

• Interface<br />

• RS-530<br />

• V.35, V.36/RS-449 and X.21<br />

available via adapter cables (see<br />

Ordering)<br />

• Connector<br />

25-pin D-type, female<br />

• <strong>Data</strong> Rate<br />

n × 56 kbps or n × 64 kbps,<br />

n=1 to 32<br />

• Clock Modes<br />

DCE: Rx and Tx clock to<br />

synchronous DTE<br />

DTE1: Rx clock to synchronous<br />

device; Tx clock from<br />

synchronous device<br />

DTE2: Rx and Tx clock from DCE<br />

• Control Signals<br />

• CTS follows RTS or constantly<br />

ON, strap selectable<br />

• DSR constantly ON, unless in<br />

test mode<br />

• DCD constantly ON, unless in<br />

local sync loss<br />

ETHERNET BRIDGE PORTS<br />

• LAN Table<br />

• IR-ETH: 10,000 addresses<br />

• IR-ETH/Q: 2,000 addresses<br />

• Filtering and Forwarding<br />

• IR-ETH: 15,000 pps<br />

• IR-ETH/Q: 2,000 pps<br />

• Buffer<br />

256 frames<br />

• Delay (IR-ETH only)<br />

1 frame<br />

• Line Code<br />

Manchester<br />

• WAN Protocol<br />

HDLC<br />

Note: IR-ETH and IR-ETH/Q interface<br />

modules conform to the IEEE<br />

802.3/Ethernet V2 standard.<br />

Additionally, IR-ETH/Q supports the<br />

IEEE 802.1/Q frames.<br />

• Connector<br />

Shielded RJ-45<br />

GENERAL<br />

• Diagnostics<br />

Local loopback on E1 port<br />

Local and remote loopbacks on<br />

data port<br />

BER test on data port<br />

• Indicators<br />

PWR, RTS, TEST, ERR,<br />

10 -3 , TD, RD<br />

SYNC LOSS: LOC, REM<br />

ALARM: MIN, MAJ<br />

• Physical<br />

• Standalone:<br />

Height: 4.4 cm (1.7 in) (1U)<br />

Width: 19.3 cm (8 in)<br />

Depth: 24 cm (9.5 in)<br />

Weight: 1.3 kg (2.9 lb)<br />

• Card:<br />

Dimensions: fits the<br />

ASM-MN-214 modem rack<br />

Weight: 360 g (10 oz)<br />

• Power<br />

AC: 100 to 240 VAC; 47 to 63 Hz<br />

DC: -48 VDC (-40 to -57 VDC)<br />

24 VDC (18 to 36 VDC)<br />

• Power consumption:<br />

5W<br />

• Environment<br />

Temperature: 0°-50°C (32°-122°F)<br />

Humidity: Up to 90%,<br />

non-condensing


<strong>FCD</strong>-<strong>2L</strong><br />

E1 or Fractional E1 Access Unit<br />

ORDERING<br />

<strong>FCD</strong>-<strong>2L</strong>/~/&/@<br />

E1 or Fractional E1 Access Standalone<br />

Unit<br />

<strong>FCD</strong>-<strong>2L</strong>/R/&/@<br />

E1 or Fractional E1 Access Card for<br />

ASM-MN-214 Rack<br />

~ Specify power supply voltage:<br />

AC for 110 VAC to 240 VAC<br />

48 for -48 VDC<br />

24 for 24 VDC<br />

& Specify data port interface:<br />

530 for RS-530<br />

V35 for V.35<br />

X21 for X.21<br />

V36 for V.36/RS-449<br />

ETUB for UTP (10BaseT) Ethernet<br />

bridge<br />

ETUQ for UTP (10BaseT) Ethernet<br />

bridge with VLAN support<br />

@ Specify LTU for integral line<br />

termination unit<br />

Default is without LTU<br />

SUPPLIED ACCESSORIES<br />

AC power cord (if AC power supply is<br />

ordered)<br />

DC adapter plug (if DC power supply<br />

is ordered)<br />

CABLES<br />

Interface adapter cables for DB-25<br />

channel connectors (DCE clock mode<br />

only). Cable length is 2m (6 ft).<br />

CBL-HS2/V/1/# for 34-pin V.35, DCE<br />

CBL-HS2/R/1/# for 37-pin V.36, DCE<br />

CBL-HS2/X/1/# for 15-pin X.21, DCE<br />

# Specify cable connector type:<br />

F for female<br />

M for male<br />

OPTIONAL ACCESSORIES<br />

RM-9<br />

Hardware kit for mounting one or<br />

two units side-by-side in a 19-inch<br />

rack<br />

CABLES<br />

Interface adapter cables for DB-25<br />

channel connectors (DTE1 and DTE2<br />

clock modes). Cable length is 2m<br />

(6 ft).<br />

CBL-HS2/*/#<br />

* Specify interface, clock mode:<br />

V/2 for 34-pin V.35, DTE1<br />

V/3 for 34-pin V.35, DTE2<br />

R/2 for 37-pin V.36/RS-449, DTE1<br />

R/3 for 37-pin V.36/RS-449, DTE2<br />

# Specify cable connector type:<br />

F for female<br />

M for male<br />

CIA-<strong>FCD</strong><strong>2L</strong>/*<br />

Mechanical adapter for converting<br />

DB-25 connectors into standard<br />

connectors for <strong>FCD</strong>-<strong>2L</strong>/R<br />

* V35/1 for V.35 interface<br />

X21/1 for X.21 interface<br />

ETU/1 for Ethernet interface<br />

www.rad.com<br />

International Headquarters<br />

24 Raoul Wallenberg Street<br />

Tel Aviv 69719, Israel<br />

Tel: 972-3-6458181<br />

Fax: 972-3-6498250<br />

Email: market@rad.com<br />

North America Headquarters<br />

900 Corporate Drive<br />

Mahwah, NJ 07430, USA<br />

Tel: (201) 529-1100<br />

Toll free: 1-800 444-7234<br />

Fax: (201) 529-5777<br />

Email: market@radusa.com<br />

171-100-11/05<br />

© 1991–2005 <strong>RAD</strong> <strong>Data</strong> <strong>Communications</strong> Ltd. Specifications are subject to change without prior notice.<br />

All other trademarks are the property of their respective holders.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!