<strong>SSPA</strong> <strong>Remote</strong> <strong>Control</strong> <strong>Panel</strong><br />
RCP-2000<br />
Introduction<br />
The RCP-2000 allows you to easily monitor and control any ModuMAX or QuadMod solid-state power amplifier (<strong>SSPA</strong>) or<br />
other compatible <strong>SSPA</strong> from a remote location. The RCP-2000 enables the remote, real-time operation of a single <strong>SSPA</strong>,<br />
which is especially convenient for installations where the <strong>SSPA</strong> is located in an inaccessible or inconvenient location.<br />
Features<br />
• Duplicates menus and functions available at <strong>SSPA</strong><br />
front panel<br />
• Provides customer Serial I/O port (up to 28.8 kBps)<br />
• Audible alarm<br />
• Worldwide AC input capability<br />
• Can be located up to 1.3 km (4000') from <strong>SSPA</strong> with<br />
inexpensive cable<br />
• Compatible with all ModuMAX or QuadMod <strong>SSPA</strong>s<br />
with firmware version 1.0x or higher<br />
Part Number/Ordering Information<br />
RCP-2000<br />
Options<br />
1 Rack Slides<br />
3 Parallel I/O<br />
5 DC Power 24 V<br />
6 DC Power 48 V<br />
Order cable ACAB-13106-X separately<br />
(where ‘X’ denotes length in feet).<br />
Front <strong>Panel</strong><br />
RF ON<br />
PREV<br />
WARNING<br />
GAIN<br />
MODIFY<br />
MENU<br />
FAULT<br />
RCP-2000<br />
MUTE<br />
SEL<br />
FAULT<br />
RESET<br />
Rear <strong>Panel</strong><br />
85-264 V<br />
47-63 Hz<br />
SERIAL I/O<br />
<strong>SSPA</strong> LINK<br />
AUX<br />
OPTION 3 PARALLEL I/O<br />
J1<br />
J2<br />
RCP-2001<br />
VX.XX<br />
J3<br />
J4<br />
FOR CONTINUED PROTECTION AGAINST FIRE,<br />
REPLACE ONLY WITH SAME TYPE AND RATING<br />
OF FUSE.<br />
Connector Interface<br />
Ref. Des. Function Connector Type Mating Connector Comment<br />
J1 AC In IEC 320 IEC Cordset Standard<br />
" DC In 4-pin MS, Male 4-pin MS, Female Option 5 or 6<br />
J2 Serial I/O 9-pin D, Female 9-pin D, Male Standard<br />
J3 <strong>SSPA</strong> Link 9-pin D, Male 9-pin D, Female Standard<br />
J5 Parallel I/O 37-pin D, Male 37-pin D, Female Option 3
Specifications<br />
Parameter Notes Min. Nom./Typ. † Max. Units<br />
Power Requirements Voltage, Standard 85 265 Vac<br />
Frequency 47 63 Hz<br />
Power 13.5 W<br />
Voltage, Option 5 20 32 Vdc<br />
Voltage, Option 6 42 56 Vdc<br />
Operating Temperature Range 0 +50 °C<br />
<strong>SSPA</strong> Link Cable Length 4000 (1.3) ft (km)<br />
Size 19 W x 1.72 H x 17.52 D inches<br />
482.6 x 43.7 x 445 mm<br />
†<br />
When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are<br />
intended to illustrate typical performance, but are not guaranteed.<br />
Parallel I/O (Option 3)<br />
The RCP-2000's parallel I/O (Option 3) provides eight independent contact-closure inputs and eight Form 'C' outputs<br />
which can be used with or without the parallel I/O option on the <strong>SSPA</strong>. Each input or output is easily configured via<br />
the RCP-2000's front panel display and an extensive menu of <strong>SSPA</strong> control and status monitoring options.<br />
Inputs *<br />
No function<br />
User Fault (Active High)<br />
User Fault (Active Low)<br />
Mute<br />
Un-Mute<br />
Mute/Un-Mute Toggle<br />
Mute (Low)/Un-Mute (High)<br />
RF Inhibit (Active Low)<br />
RF Inhibit (Active High)<br />
Fault Reset<br />
Outputs *<br />
No function (user-defined function)<br />
Forward Power Fault (High or Low)<br />
Reflected Power Fault (High or Low)<br />
Any Fault<br />
<strong>Remote</strong>/Local Mode<br />
Maintenance Mode<br />
RF Inhibit<br />
RF On/Off<br />
Mute/Operate<br />
Fan Fault<br />
Module Fault<br />
Any Warning<br />
Temperature Fault<br />
Any Fault or Warning<br />
Power Supply Module Fault<br />
Ratings<br />
Inputs:<br />
Contact closure to ground<br />
(5 V/5 mA)<br />
Outputs:<br />
Form 'C' dry contacts<br />
100 V/0.5 A/3 W maximum<br />
* Additional functions may be offered for <strong>SSPA</strong>s with optional hardware features.<br />
Other Products<br />
• Low Noise Amplifiers and LNA Systems<br />
• Solid-State Power Amplifiers and <strong>SSPA</strong> Systems<br />
• <strong>General</strong> Purpose Converters<br />
• Satellite Communications Equipment<br />
• Custom Subsystems<br />
60 Decibel Road, Suite 200 • State College, PA 16801 USA • Tel. 814 238 2700 • FAX 814 238 6589 12719 Rev. – As Issued 11/6/00 RJS<br />
Web Site: www.gdsatcom.com/electronics.php<br />
© <strong>General</strong> <strong>Dynamics</strong>. All rights reserved. <strong>General</strong> <strong>Dynamics</strong> reserves the right to make changes to its products and specifications at any time and without notice.<br />
All trademarks indicated as such herein are trademarks of <strong>General</strong> <strong>Dynamics</strong>. All other product and service names are the property of their respective owners.