7. Grout in new tile.<br />

8. Saw cut the coping and install a bead <strong>of</strong> caulk.<br />

9. Coping cut shall be made through the full thickness <strong>of</strong> the deck slab.<br />

10. Cut shall be pressure washed and allowed to dry be<strong>for</strong>e caulk (vulchem 116 or equal) is<br />

applied.<br />

11. Water line tile will be done be<strong>for</strong>e re-plastering <strong>of</strong> pool.<br />

102.2 – EXPANSION JOINTS IN POOL<br />

1. Remove all existing expansion joint tile.<br />

2. Remove all <strong>of</strong> the backer rod and or filler material.<br />

3. Furnish and install rod and tile with new tile 4”x4” that is chemical resistant, frost pro<strong>of</strong><br />

and is non-skid ceramic tile. Color – black.<br />

102.3 – STAIR TRIM TILE<br />

1. Furnish and replace stair trim tile with new tile that is chemical resistant, frost pro<strong>of</strong> and<br />

non-skid tile – color to be chosen by Owner.<br />

103 – MAIN DRAIN<br />

1. Drain grates and frames must be VGB certified and comply with ANSI/ASME<br />

A112.19.8-2007 <strong>for</strong> use in swimming pool.<br />

2. Remove existing main drain frame and grate.<br />

3. Verify sumps meet VGB requirements.<br />

4. Net opening in each floor outlet covering or grating shall be at least four times the area so<br />

that maximum velocity <strong>of</strong> the water passing the grate will not exceed one and one-half<br />

feet per second (1-1/2fps)<br />

5. Saw cut out 18’x18’ section <strong>of</strong> pool floor. Install new 18’x18’ waterway (or equivalent)<br />

grates and frame.<br />

104 – SKIMMERS<br />

1. Skimmers shall comply with NSF International Standard 50 and VGB compliant.<br />

2. Saw cut deck and remove existing skimmers and piping.<br />

3. Remove existing skimmer throats.