F56 - DripSafeâ⢠AirJet Fogger Spray Nozzles - Spraying Systems ...
F56 - DripSafeâ⢠AirJet Fogger Spray Nozzles - Spraying Systems ...
F56 - DripSafeâ⢠AirJet Fogger Spray Nozzles - Spraying Systems ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
DripSafe<br />
Special Purpose<br />
<strong>Fogger</strong> <strong>Spray</strong> <strong>Nozzles</strong>,<br />
Air Atomizing <strong>Nozzles</strong><br />
Features and Benefits<br />
• High-volume/high-efficiency air atomization.<br />
• Produces an adjustable, high-quality dry fog without wetting with<br />
pressure-fed liquid.<br />
• Ideal for large/open structures and areas with high air exchange rates.<br />
• Operation is through a drip safe air-actuated liquid shut-off valve.<br />
• Automatically prevents liquid from spraying until air pressure at the<br />
nozzle is sufficient for fine atomization.<br />
• Drip safe valve simplifies system construction and control while<br />
improving performance.<br />
• Operates using normal water pressures found in municipal water<br />
systems, eliminating the need for expensive, high-pressure hydraulic<br />
pumps.<br />
• Air requirements are met using an air compressor with a<br />
capacity range that is suitable for the application.<br />
• Requires minimal maintenance.<br />
• The flat spray tip has a large orifice that reduces clogging.<br />
• <strong>Spray</strong> set-up and built-in strainer are quickly removed by<br />
hand if cleaning is required.<br />
• <strong>Spray</strong> tip is brass; valve and body polymer.<br />
• Operates at pressures up to 100 psi (7 bar) with a minimum<br />
air pressure range of 25 to 35 psi (1.7 to 2.5 bar).<br />
• A split-eyelet or saddle clamp version of the <strong>AirJet</strong><br />
<strong>Fogger</strong> (45269 Series) is also available for quick and easy<br />
mounting to the liquid supply pipe.<br />
45265<br />
45269<br />
Optimization Tips<br />
• See page F2 for optimization tips.<br />
Applications<br />
1/4" NPT or BSPT (F) Split-eyelet type to clamp on<br />
pipe 1/2" to 1"<br />
• Evaporative cooling<br />
• Fogging<br />
• Humidification<br />
• Insecticide spraying<br />
• Plant propagation<br />
Specifications<br />
Nozzle<br />
Inlet<br />
Conn.<br />
(in.)<br />
<strong>AirJet</strong><br />
<strong>Fogger</strong><br />
Type<br />
1/4 45265<br />
Fluid<br />
Orifice<br />
No.<br />
Orifice<br />
Dia.<br />
Nom.<br />
(in.)<br />
16.0 .016<br />
20 .020<br />
26 .026<br />
See Also<br />
• Accessories<br />
– Air line filters<br />
– Pressure gauges<br />
– Air pressure regulators – Solenoid valves<br />
– Liquid pressure regulators – Strainers<br />
• For 23412 and QJ25655, request Data Sheets 23412<br />
and 25635<br />
• For 45265 and 45269, request Data Sheets 45265-1-2<br />
and 45269-1-2<br />
http://<br />
To Clamp On<br />
Pipe<br />
Size<br />
(in.)<br />
1/2<br />
<strong>AirJet</strong><br />
<strong>Fogger</strong><br />
Type<br />
Fluid<br />
Orifice<br />
No.<br />
Orifice<br />
Dia.<br />
Nom.<br />
(in.)<br />
16.0 .016<br />
3/4 45269<br />
20 .020<br />
1 26 .026<br />
Phone 1-800-95-spray, FAX 1-888-95-spray<br />
Visit Our Web Site: www.spray.com, Email: info@spray.com<br />
<strong>F56</strong>
DripSafe<br />
Special Purpose<br />
<strong>Fogger</strong> <strong>Spray</strong> <strong>Nozzles</strong>,<br />
Performance Data<br />
45265, 45269<br />
Water<br />
Pressure<br />
20<br />
30<br />
40<br />
Fluid Orifice No. 16 (.016" Dia.)<br />
Air Pressure*<br />
*At the stated pressure in psi.<br />
10 20 30 40 50 60 70 80<br />
1.2 1.1 – – – – – –<br />
1.5 2.5 – – – – – –<br />
1.7 1.5 1.2 – – – – –<br />
1.4 2.4 3.4 – – – – –<br />
2.0 1.7 1.5 1.4 – – – –<br />
1.4 2.4 3.3 4.2 – – – –<br />
45265, 45269<br />
Water<br />
Pressure<br />
20<br />
30<br />
40<br />
Fluid Orifice No. 20 (.020" Dia.)<br />
Air Pressure*<br />
*At the stated pressure in psi.<br />
10 20 30 40 50 60 70 80<br />
3.1 1.7 – – – – – –<br />
1.4 2.8 – – – – – –<br />
3.6 2.1 1.7 – – – – –<br />
1.3 2.5 3.6 – – – – –<br />
4.3 3.1 2.2 – – – – –<br />
1.2 2.3 3.4 – – – – –<br />
45265, 45269<br />
Water<br />
Pressure<br />
20<br />
30<br />
40<br />
Fluid Orifice No. 26 (.026" Dia.)<br />
Air Pressure*<br />
*At the stated pressure in psi.<br />
10 20 30 40 50 60 70 80<br />
3.3 1.8 – – – – – –<br />
1.3 2.4 – – – – – –<br />
4.3 3.4 2.1 – – – – –<br />
1.1 2.1 3.2 – – – – –<br />
– 4.5 3.6 2.4 – – – –<br />
– 1.9 2.8 3.9 – – – –<br />
In each line, figures in plain face indicate water atomized in gph (l/h)<br />
at psi (bar) water pressure.<br />
Figures in boldface indicate atomizing air in scfm (Nl/min) at psi (bar)<br />
air pressure.<br />
1. Values in blue area show optimum evaporation under normal<br />
room conditions, when center line of spray is 5' (1.5 m) from the<br />
lower surface.<br />
2. Values in red area can require up to 10' (3 m) for evaporation.<br />
Other values may be used where extended heat, higher air<br />
velocity exist or where slight surface wetting is permitted.<br />
3. <strong>AirJet</strong> <strong>Fogger</strong> has a horizontal throwing distance of 15' (4.5 m)<br />
and will expand to approximately 8' (2.4 m) wide/3' (.9 m) thick.<br />
Air Atomizing<br />
nozzles<br />
Ordering Info<br />
Complete Nozzle<br />
Assembly<br />
45265 – 1/4 – 16<br />
l l l<br />
Nozzle<br />
Body<br />
Inlet<br />
Conn.<br />
Fluid<br />
Orifice<br />
Dia.<br />
Complete Nozzle<br />
Assembly<br />
45269 – 1/2 – 16<br />
l l l<br />
Nozzle<br />
Body<br />
Pipe<br />
Size<br />
Fluid<br />
Orifice<br />
Dia.<br />
BSPT connections require the addition of a “B” prior to the nozzle body<br />
inlet connection.<br />
Phone 1-800-95-spray, FAX 1-888-95-spray<br />
Visit Our Web Site: www.spray.com, Email: info@spray.com<br />
F57