Your supplier for ELEKTRONIK<br />

XRF Application Solutions Fusion machines<br />

CATALOGUE<br />

Applications<br />

Liquid analysis<br />

Solid analysis<br />

Fusion techniques


1<br />

H Hydrogen<br />

3<br />

Li<br />

Lithium<br />

11<br />

Na<br />

Natrium, Sodium<br />

Be<br />

Berylium<br />

6,941 4 9,012<br />

22,990 12 24,305<br />

Mg<br />

Magnesium<br />

19 39,098<br />

K<br />

20 40,078<br />

Ca<br />

Kalium, Potassium Calcium<br />

37<br />

Rb<br />

Rubidium<br />

55<br />

87<br />

Cs<br />

Cesium<br />

1,008<br />

0,7420 Na2O 1,3477 0,6030 MgO 1,6584<br />

0,8300 K2O 1,2048<br />

38<br />

Sr Strontium<br />

Ba<br />

132,905 56 137,327<br />

Fr<br />

Francium<br />

85,468 87,62<br />

223,02<br />

Barium<br />

0,8960 BaO 1,1161<br />

0,5884 BaSO4 1,6995<br />

88<br />

Ra<br />

Radium<br />

226,025<br />

21<br />

Sc Scandium<br />

39<br />

Periodic Table of Fusion<br />

Ti<br />

Titanium<br />

V<br />

44,956 22 47,88 23 50,996<br />

YYtrrium<br />

40<br />

Zr Zirconium<br />

72<br />

Hf<br />

Hafnium<br />

41<br />

Nb<br />

Niobium<br />

88,905 91,224 92,906<br />

Ta<br />

Tantalum<br />

178,49 73 180,948<br />

57 138,906<br />

La<br />

Lanthanum<br />

89<br />

Ac<br />

Actinium<br />

227,028<br />

58<br />

90<br />

Ce<br />

Cerium<br />

140,115<br />

Th<br />

Thorium<br />

232,038<br />

24<br />

Cr<br />

Chromium<br />

51,996<br />

42 95,940<br />

Mo<br />

Molybdenum<br />

74<br />

W<br />

Wolfram, Tungsten<br />

25 54,938<br />

Mn<br />

43 98,906<br />

Tc<br />

Technetium<br />

Re<br />

Rhenium<br />

26<br />

Fe<br />

44<br />

Ru<br />

Ruthetium<br />

Os<br />

Osmium<br />

27<br />

Co Cobalt<br />

45<br />

Rh<br />

Rhodium<br />

Ir<br />

Indium<br />

28<br />

Ni<br />

Nickel<br />

46<br />

Pd<br />

Palladium<br />

Pt<br />

Platinum<br />

Z<br />

Symbol<br />

Element<br />

29<br />

Cu Copper<br />

Ag<br />

Silver<br />

79<br />

Au Gold<br />

30<br />

Zn Zinc<br />

Hg<br />

Mercury<br />

5<br />

BBoron<br />

13<br />

Al<br />

Aluminium<br />

31<br />

Ga Galium<br />

183,85 75 186,207 76 190,2 77 192,22 78 195,08 196,967 80 200,59 81 204,383<br />

59 140,908<br />

Pr<br />

Praseodynium<br />

91 231,036<br />

Pa<br />

Protactinium<br />

60<br />

Nd<br />

Neodymium<br />

92<br />

UUranium<br />

144,24<br />

238,029<br />

55,847<br />

61<br />

Pm<br />

Promethium<br />

93<br />

Np<br />

Neptunium<br />

58,933<br />

50,996 101,07<br />

62<br />

Sm<br />

Samarium<br />

146,915 150,36<br />

94<br />

Pu<br />

Plutonium<br />

237,048 244,064<br />

63<br />

Eu<br />

Europium<br />

95 243,061<br />

Am<br />

Americium<br />

58,69 63,546 65,39 69,723<br />

Gd<br />

Gadolinium<br />

96 247,07<br />

Cm<br />

Curium<br />

A<br />

Ox>El Oxid El>Ox<br />

Vanadium<br />

Manganese<br />

0,7745 MnO 1,2912<br />

Iron<br />

0,7770 FeO 1,2870<br />

0,7150 CaO 1,3986<br />

0,5133 CaF2 1,9480 0,6520 Sc2O3 1,5337 0,6000 TiO2 1,6667<br />

0,6798 V2O3 1,4711<br />

0,5600 V2O5 1,7857 0,6840 Cr2O3 1,4620<br />

0,6960 Mn2O3 1,4368<br />

0,7203 Mn3O4 1,3883<br />

0,6990 Fe2O3 1,4306<br />

0,7236 Fe3O4 1,3820 0,7860 CoO 1,2723 0,7860 NiO 1,2723 0,7990 CuO 1,2516 0,8030 ZnO 1,2453<br />

Cd<br />

Cadmium<br />

Tb<br />

Terbium<br />

97<br />

Bk<br />

Berkelium<br />

10,811<br />

6<br />

12,011 7 14,007 8<br />

CCarbon<br />

Si<br />

Silicon<br />

26,982 14 28,086<br />

In<br />

Indium<br />

Tl<br />

Thallium<br />

Dy<br />

Dysprosium<br />

98 251,079<br />

Cf<br />

Californium<br />

32 72,61<br />

Ge<br />

Germanium<br />

Sn<br />

Tin<br />

106,42 47 107,868 48 112,411 49 114,82 50 118,71<br />

82<br />

Pb Lead<br />

Ho<br />

Holmium<br />

99 252,083<br />

Es<br />

Einsteinium<br />

NNitrogen<br />

15<br />

P Phosphorus<br />

33<br />

As<br />

Arsenic<br />

51<br />

Sb<br />

Antimony<br />

Bi<br />

Bismuth<br />

Er<br />

Erbium<br />

100<br />

Fm<br />

Fermium<br />

34<br />

OOxygen<br />

S<br />

15,999<br />

Se<br />

Selenium<br />

Te<br />

Tellurium<br />

Po<br />

Polonium<br />

69<br />

Tm<br />

Thulium<br />

101 258,099<br />

Md<br />

Mendelevium<br />

9<br />

F<br />

Fluorine<br />

Cl<br />

Chlorine<br />

2<br />

He Helium<br />

10<br />

Ne Neon<br />

Ar<br />

Argon<br />

30,974 16 32,066 17 35,453 18 39,948<br />

74,922<br />

151,965 64 157,25 65 158,925 66 162,50 67 164,930 68 167,26<br />

247,07<br />

0,5290 Al2O3 1,8904 0,4670 SiO2 2,1413 0,4360 P2O5 2,2936<br />

78,96<br />

35<br />

Br<br />

Bromine<br />

Kr<br />

Krypton<br />

79,904 36 83,80<br />

I<br />

Iodine<br />

Xe<br />

Xenon<br />

121,75 52 127,60 53 126,904 54 131,29<br />

At<br />

Astatium<br />

70<br />

Yb<br />

Ytterbium<br />

102<br />

No<br />

Nobelium<br />

86<br />

Rn Radon<br />

71<br />

4,003<br />

18,998 20,183<br />

207,19 83 208,980 84 208,982 85 209,987 222,018<br />

257,095<br />

Sulphur<br />

0,4000 SO3 2,5000<br />

0,3338 SO4 2,9959<br />

0,7440 Ga2O3 1,3441 0,6940 GeO2 1,4409 0,7570 As2O3 1,3210 0,7120 SeO2 1,4045<br />

0,9140 Rb2O 1,0941 0,8460 SrO 1,1820 0,7874 Y2O3 1,2700 0,7400 ZrO2 1,3514 0,6990 Nb2O5 1,4306 0,6670 MoO3 1,4993<br />

0,9310 Ag2O 1,0741 0,8750 CdO 1,1429 0,8270 In2O3 1,2092 0,7880 SnO2 1,2690 0,8350 Sb2O3 1,1976 0,8000 TeO2 1,2500<br />

0,8480 HfO2 1,1792 0,8190 Ta2O5 1,2210 0,7930 WO3 1,2610 0,8534 ReO2 1,1719<br />

0,8949 Tl2O3 1,1174 0,9280 PbO 1,0776 0,8970 Bi2O3 1,1148<br />

0,8527 La2O3 1,1727 0,8141 CeO2 1,2284 0,8277 Pr6O11 1,2082 0,8574 Nd2O3 1,1663<br />

0,8623 Sm2O3 1,1596 0,8636 Eu2O3 1,1579 0,8676 Gd2O3 1,1526 0,8502 Tb4O7 1,1762 0,8713 Dy2O3 1,1477 0,8730 Ho2O3 1,1455 0,8745 Er2O3 1,1435 0,8756 Tm2O3 1,1421 0,8782 Yb2O3 1,1387 0,8794 Lu2O3 1,1372<br />

0,8790 ThO2 1,1377<br />

0,9084 U2O3 1,1008<br />

All indicated elements can be fused with lithium tetraborate FX-X100.<br />

As standard recipe a ratio of 1:8 to 1:10 (sample : fl ux) is assumed.<br />

Depending on diff erent solubilities of pure oxides higher dilution could be necessary.<br />

168,934<br />

173,04<br />

Lu<br />

Lutetium<br />

174,967<br />

103<br />

Lr<br />

Lawrencium<br />

259,10 260,105<br />

Group of volatile elements F, Cl, S<br />

These elements show a loss in dependence of fusion temperature, precise temperature<br />

setting required for high precision fusion.<br />

Group of elements causing sticking in the mould Fe, Co, Cu, Cr<br />

These elements change the viscosity of the melt depending on their concentrations.<br />

This can only be eliminated by adding bromide or iodide salts.<br />

This applies for: Fe > 40%, Co, Cu > 0.1, Cr > 0.5%<br />

Group of elements which colour the fusion<br />

Green Cr, Tm<br />

Brown V, Mn, Fe, Ni, Pb, Bi<br />

Blue Co, Cu<br />

Orange Ce<br />

Pink Yb, Nd, Eu, Er, Ho<br />

Yellow Sm, Dy<br />

Group of compounds which need pre-treatment<br />

Minerals with carbon : continuous casting powder<br />

Sulfi de ores : FeS, CuS, ZnS, MoS, PbS<br />

Metal alloys : FeNiCo, FeSi, FeMn, FeMo, … FeXX<br />

Organic compounds : Ca, Pb stearates<br />

These <strong>materials</strong> have to be oxidized fi rst before normal fusion to avoid reaction<br />

with platinum ware.<br />

The Periodic Table of Fusion is also available as poster on request.


Table of Contents<br />

1 Applications 2<br />

2 Liquid Analysis 6<br />

2.1 Sample Cups 7<br />

Universal 7<br />

Spectro® 8<br />

Oxford® 10<br />

Horiba® 10<br />

Philips/Panalytical® 11<br />

Bruker® and Thermo ARL® 12<br />

2.2 Thin Films 13<br />

Mylar® Film 13<br />

Microporous Polypropylene Film 13<br />

Microporous Teflon Film 13<br />

Polypropylene Film 13<br />

Kapton® 13<br />

Tape for XRF-Analysis 13<br />

3 Solid analysis 15<br />

3.1 Press 16<br />

3.1.1 Pellet Dies 17<br />

3.1.2 Rings 18<br />

3.1.3 Aluminium Cups 19<br />

3.1.4 Pellet Films 19<br />

3.1.5 Binding Additives for XRF-Analysis 20<br />

3.2 Mill 21<br />

3.2.1 Accessories for grinding and mixing 21<br />

4 Fusion Technique 22<br />

4.1 Vulcan Fusion Machines 23<br />

4.2 Platinum Ware 24<br />

4.3 High Purity Molten Fluxes 25<br />

5 Sample Storage 26<br />

6 FLUXANA Certified Reference Materials 28<br />

1


2<br />

Applications 1


Applications for XRF<br />

Our experts developed special calibration<br />

packages for:<br />

Cement industry<br />

Raw <strong>materials</strong><br />

Glass industry<br />

Steel industry<br />

There will be a complete analytical method installed within<br />

a few days on the X-ray fl uorescence instrument in your lab on site.<br />

Application packages<br />

FLUXANA developed fusion applications for all mentioned elements.<br />

We are pleased to help you setting up your own high precision fusion method.<br />

Ready to go application packages:<br />

Article-No.: Application<br />

CS- 0001-K FLUXANA Calibration Cement, Clinker, Raw Meal<br />

CS- 0001/7-K FLUXANA Calibration Cement + Raw Materials etc.<br />

CS- 0007-K FLUXANA Calibration OXIDES Basic<br />

CS- 0005-K FLUXANA Calibration OXIDES Advanced<br />

CS- 0016-K FUXANA Calibration Glass Industry<br />

CS- 0003e/b/c/f-K FLUXANA Calibration Ferro Alloys FeMo, FeMn, FeSi, FeSiMn<br />

CS- 0003d-K FLUXANA Calibration Ferro Alloys FeCr<br />

CS- 0003e-K FLUXANA Calibration Ferro Alloys FeCr, FeV,...<br />

CS- 0009 FLUXANA Calibration Customer Specifi c<br />

CS- 0017-K FLUXANA Calibration Slags, Casting Powders<br />

All standard calibrations are performed in our own application laboratory.<br />

Your test samples are welcome in our laboratory.<br />

We would like to develop new methods with your cooperation.<br />

Finally we will transfer them into your lab.<br />

Ask for a free presentation in our lab whenever you like.<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

Applications 1<br />

3


4<br />

1 Applications<br />

Your advantages with developing the Application on us:<br />

1. No development time in your laboratory<br />

2. Cost saving in your lab<br />

3. Fast introduction of new methods in your lab<br />

4. Easy calculation of costs<br />

5. Guarantee on reproducibility an accuracy<br />

6. Calibration with highest quality<br />

7. Newcomers become experts quickly<br />

8. Guaranteed after sales support<br />

Typical content of a package<br />

Sample preparation tools: fusion machine, mill, press<br />

Chemicals: fl ux, binder, grinding agence<br />

1 set calibration standards ready for measurement<br />

1 set drift correction samples<br />

1 set validation samples<br />

Installation of measuring program on your xrf instrument in<br />

your lab on site<br />

Calibrating on site<br />

Validation with your own samples<br />

Training of your laboratory staff<br />

Customer acceptance<br />

After sales support from our experts in xrf<br />

Contribution in our round robin tests<br />

Cross check of routine results with our application laboratory<br />

Vulcan 4MA Press<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com


Drift monitors<br />

After establishing a calibration on an X-ray fl uorescence instrument<br />

everybody likes to use it as long as possible.<br />

This wouldn’t be any problem if the instrument would not show any<br />

changes in sensitivity over time. But it is the opposite.<br />

The x-ray tube looses intensity and the detector looses sensivity<br />

over time. Service works for example changing an x-ray tube or a<br />

crystal might have an infl uence to the sensitivity as well.<br />

To use an existing calibration over a long time the change in sensitivity<br />

for an element has to be detected by a drift monitor and then used to<br />

correct for it. Such samples are called drift monitors, monitor samples,<br />

<strong>reference</strong> samples or monitor standards.<br />

FLUXANA calibrations, installed in many customer laboratories,<br />

contain a special selection of drift monitors to guarantee an excellent<br />

long term stability.<br />

These monitor samples were designed especially for the use in our<br />

customer applications.<br />

Driven by customers we produce monitor samples in our glass<br />

production designed on the customer need.<br />

Examples for FLUXANA monitor glasses:<br />

FLX-C1, C3, Z1, Z2, Z3 Cement, raw <strong>materials</strong> cement industry, glass industry<br />

FLX-S13 Multi- element X-ray calibration<br />

FLX-S6M X-ray calibration<br />

FLX-SP1, SP2 Raw <strong>materials</strong>, ores<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

Applications 1<br />

5


6<br />

Liquid Analysis 2<br />

Sample Cups 2.1<br />

Thin Films 2.2


Universal<br />

The sample cups of FLUXANA are designed for use in XRF.<br />

All cups have been optimized and approved by our<br />

customers world wide.<br />

Universal single open ended cups; 32 & 40mm<br />

Part No. Description OD<br />

mm<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

ID<br />

mm<br />

H<br />

mm<br />

SC-4031 Cup, ring, single open ended, universal open for 32mm holder 32 25 24 12<br />

SC-4131 Cup, ring, collar single open ended, universal for 32mm holder 32 25 24 12<br />

SC-4140 Cup, ring, collar single open ended, universal for 40mm holder 40 32 24 18<br />

One set contains 100 pieces. Caps and rings are packed separately! No cutting necessary!<br />

Selected for single-open conditions allowing backpressure from bottom loading of sample.<br />

Unique Oversize Ring delivers True Tautness of Thin Film attachments for smooth plane.<br />

SC-4131 and SC-4140 includes collar for Thin Film Attachment Stability.<br />

Bi-Directional Ring or Sleeve ensures ease of use and efficient “Ring to Cup Assembly”.<br />

Thermoplastic ventable recessed seal for venting/pressure equalization.<br />

Handling of liquids, volatiles, powders and slurries in air or helium.<br />

Universal<br />

Universal double open ended cups; 32 & 40mm<br />

without caps<br />

Part No. Description OD<br />

mm<br />

ID<br />

mm<br />

H<br />

mm<br />

SC-4231 Cup, 2 rings, double open ended, universal for 32mm holder 32 25 24 12<br />

SC-4240 Cup, 2 rings, double open ended, universal for 40mm holder 40 32 24 18<br />

One set contains 100 pieces. Caps and rings are packed separately! No cutting necessary!<br />

Selected for double-open conditions allowing convenient top loading of samples.<br />

Open end may be sealed with a ventable cap, for full enclosure of the sample.<br />

Unique Oversize Ring delivers True Tautness of Thin Film attachments for smooth plane.<br />

Bi-Directional Ring ensures ease of use and efficient “Ring to Cup Assembly”<br />

Handling of liquids, and most difficult volatiles, including lower density powders or dust.<br />

Ventable Caps with reserviour (included).<br />

Liquid Analysis 2<br />

Sample Cups 2.1<br />

Vol<br />

ml<br />

Vol<br />

ml<br />

7


8<br />

2 Liquid Analysis<br />

2.1 Sample Cups<br />

Type (1) Type (2)<br />

Part No. Description OD<br />

mm<br />

Universal<br />

Universal double open<br />

ended cups with caps;<br />

32 & 40mm<br />

ID<br />

mm<br />

H<br />

mm<br />

SC-4331 (1) Cup, ring, universal for 32mm holder 32 25 24 12<br />

SC-3332 (2) Cup, ring, cap universal for 32mm holder 32 25 23 10<br />

SC-3335 (2) Cup, ring, cap universal for 35mm holder 35 28 30 18<br />

SC-4340 (1) Cup, ring, cap universal for 40mm holder 40 32 24 18<br />

SC-3340 (2) Cup, ring, cap universal for 40mm holder 40 34 21 18<br />

SC-3340-T (2) Cup, ring, cap universal for 40mm holder 40 34 29 25<br />

SC-3345 (2) Cup, ring, cap universal for 45mm holder 45 37 40 40<br />

SC-3351 (2) Cup, ring, cap universal for 51mm holder 51 44 33 50<br />

One set contains 100 pieces. Caps and rings are packed separately! No cutting necessary!<br />

Selected for double-open conditions allowing convenient top loading of samples.<br />

Open end may be sealed with a ventable cap, for full enclosure of the sample.<br />

Unique Oversize Ring delivers True Tautness of Thin Film attachments for smooth plane.<br />

Bi-Directional Ring ensures ease of use and efficient “Ring to Cup Assembly”<br />

Handling of liquids, and most difficult volatiles, including lower density powders or dust.<br />

Ventable caps with reservoir (included).<br />

Part No. Description OD<br />

mm<br />

Vol<br />

ml<br />

Spectro®<br />

Double open ended suitable<br />

for Spectro® analyzers; 32 & 40mm<br />

ID<br />

mm<br />

H<br />

mm<br />

SC-4231 Cup, 2 rings for Spectro® Asoma 200, 200T, Titan, Phoenix 32 25 24 12<br />

SC-4331 Cup, ring, cap for Spectro® Asoma 200, 200T, Titan, Phoenix 32 25 24 12<br />

One set contains 100 pieces. Caps and rings are packed separately! No cutting necessary!<br />

Selected for double-open conditions allowing convenient top loading of samples.<br />

Open end is sealed with vented cap or Microporous films resulting in full enclosure of sample.<br />

SC-4231 includes the cup with 2 rings for use with Microporous films.<br />

SC-4331 includes a cup, ring and one snap on ventable cap with reservoir overflow<br />

for pressure equalization.<br />

XRF Sample Cup is designed with centering rings for precise fit onto Spectro sample holders. Handling of<br />

liquids, volatiles, powders and slurries.<br />

Cups incorporate a ventable recessed seal with reservoir for venting/pressure equalization.<br />

Vol<br />

ml<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com


Spectro®<br />

Double open ended suitable<br />

for Spectro® analyzers;<br />

32 & 40mm<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Type (1) Type (1)<br />

Part No. Description OD<br />

mm<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

Type (2)<br />

ID<br />

mm<br />

H<br />

mm<br />

SC-6232 (1) Cup, 2 rings for Spectro® Xepos, X-Lab 2000, Xepos Low S 32 25 23 10<br />

SC-6332 (1) Cup, ring, cap for Spectro® Xepos, X-Lab 2000, Xepos Low S 32 25 23 10<br />

SC-4140 Cup, ring, cap, collar for Spectro® Xepos, X-Lab 2000, Xepos Low S 40 32 24 18<br />

SC-4240 (1) Cup, 2 rings, for Spectro® Xepos, X-Lab 2000, Xepos Low S 40 32 24 18<br />

SC-4340 (1) Cup, ring, cap for Spectro® Xepos, X-Lab 2000, Xepos Low S 40 32 24 18<br />

SC-3332 (2) Cup, ring, cap for Spectro® Xepos, X-Lab 2000, Xepos Low S 32 25 23 10<br />

One set contains 100 pieces. Caps and rings are packed separately! No cutting necessary!<br />

Liquid Analysis 2<br />

Sample Cups 2.1<br />

Selected for double-open conditions allowing for convenient top loading of samples.<br />

Open End is sealed with vented cap or Microporous films resulting in full enclosure of sample.<br />

SC-4240/6232 includes the cup with 2 rings allowing use with Microporous films.<br />

SC-4340/6332 includes a cup, ring and one snap on ventable cap with reservoir overflow<br />

for pressure equalization.<br />

XRF Sample Cup is designed with centering rings for precise fit onto Spectro sample holders.<br />

Handling of liquids, volatiles, powders and slurries.<br />

Cups incorporate a ventable recessed seal with reservoir for venting/pressure equalization.<br />

SC-4140 is selected for single-open conditions allowing backpressure from bottom loading of sample.<br />

Unique Oversize Ring delivers True Tautness of Thin Film attachments for smooth plane.<br />

SC-4140 includes a cup, ring and one collar for Thin Film Attachment Stability<br />

Vol<br />

ml<br />

9


10<br />

2 Liquid Analysis<br />

2.1 Sample Cups<br />

Part No. Description OD<br />

mm<br />

Oxford®<br />

Double open ended suitable<br />

for Oxford® analyzers; 32mm<br />

ID<br />

mm<br />

H<br />

mm<br />

SC-7332 Inner cup and cap, designed for Oxford® 32 30 38,5 25<br />

SC-7332inner Only inner cup, designed for Oxford LABX® 32 30 38,5 25<br />

SC-7332cap Only cap, designed for Oxford LABX®<br />

One set contains 100 pieces. Caps and rings are packed separately! No cutting necessary!<br />

Selected for double-open conditions allowing convenient top loading of sample.<br />

Open End is sealed with ventable reservoir for cap resulting with full enclosure of sample.<br />

XRF Cup designed for insertion into Aluminum Sleeve.<br />

Cups incorporate a ventable recessed seal with reservoir for venting/pressure equalization.<br />

Inner ring and cap can be ordered separately.<br />

Part No. Description OD<br />

mm<br />

Vol<br />

ml<br />

Horiba®<br />

Single open ended suitable for<br />

Horiba® analyzers; 47mm<br />

ID<br />

mm<br />

H<br />

mm<br />

SC-4047 Cup, ring, single open ended, for Horiba® 47 38 18,5 18<br />

SC-8047 Cup, ring, single open ended, for Horiba® 47 38 18,5 18<br />

One set contains 100 pieces. Caps and rings are packed separately! No cutting necessary!<br />

Selected for single-open conditions allowing backpressure from sample.<br />

Bottom loading style sample cup with low profile design.<br />

Suitable for Horiba and other XRF Analyzers requiring large aperture masks.<br />

Unique Oversize Ring delivers True Tautness of Thin Film attachments for smooth plane.<br />

Bi-Directional Ring ensures ease of use and efficient “Ring to Cup Assembly”<br />

Thermoplastic ventable recessed seal for venting/pressure equalization and over flow reservoir.<br />

Handling of liquid sand powders with venting provision for pressure equalization.<br />

Vol<br />

ml<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com


Philips/<br />

Panalytical®<br />

Double open ended suitable<br />

for Philips/Panalytical®<br />

analyzers; 35 & 45mm<br />

Type (1)<br />

Part No. Description OD<br />

mm<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

Type (2)<br />

ID<br />

mm<br />

H<br />

mm<br />

SC-3335 (2) Cup, ring, cap for Philips/Panalytical® 35 28 31 18<br />

SC-4335 (1) Cup, ring, cap for Philips/Panalytical® 35 27 35 18<br />

SC-3345 (2) Cup, ring, cap for Philips/Panalytical® 45 37 40 27<br />

SC-4345 (1) Cup, ring, cap for Philips/Panalytical® 45 39 32 36<br />

One set contains 100 pieces. Caps and rings are packed separately! No cutting necessary!<br />

Liquid Analysis 2<br />

Sample Cups 2.1<br />

Selected for double-open conditions allowing convenient top loading of samples. Open End is sealed<br />

with vented cap or Microporous films (Polypropylene or Teflon®) for resulting in full enclosure of sample.<br />

Precision fit design suitable for Philips PW 4015 Mini Mate & 4025 Mini Pal.<br />

Handling of liquids, volatiles, powers and slurries.<br />

Selected for double-open conditions allowing convenient top loading of samples.<br />

Open End is sealed with vented cap or Microporous films for resulting in full enclosure of sample.<br />

XRF Sample Cup is designed for precise fit onto sample holders.<br />

SC-3345 includes a cup, ring and one snap on ventable cap with reservoir<br />

overflow for pressure equalization.<br />

Handling of liquids, volatiles, powers and slurries.<br />

Vol<br />

ml<br />

11


12<br />

2 Liquid Analysis<br />

2.1 Sample Cups<br />

Bruker® and Thermo ARL®<br />

Double open ended cups for<br />

Bruker® and Thermo ARL® analyzers; 40mm<br />

Part No. Description OD<br />

mm<br />

ID<br />

mm<br />

H<br />

mm<br />

SC-3340 Inner ring, outer ring, cap for Bruker®SRS, S4, S8 + ARL Optimix® 40 34 21 18<br />

SC-3340T Inner ring, outer ring, cap for Bruker®SRS, S4, S8 + ARL® others 40 34 29 25<br />

SC-3345 Cup, ring cap for Bruker®SRS, S4 + ARL® others 45 37 40 40<br />

One set contains 100 pieces. Caps and rings are packed separately! No cutting necessary!<br />

30% smaller packaging<br />

Use straight from the bag. No scissors needed to separate components<br />

Lid, inner and outer ring packed separately<br />

Lid with reservoir for liquids<br />

Lid with matt surface for writing sample name/number<br />

Fill mark<br />

Ventilation hole in lid<br />

Nipple on lid for easy handling<br />

Easy to disassemble<br />

Compatible with Bruker S4, Siemens SRS, Thermo ARL Optimix, ARL 9000 Series,<br />

Panalytical PW Series, Spectro EDXRF, Oxford and others.<br />

Vol<br />

ml<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com


Thin Films<br />

The p<strong>reference</strong>s of our thin films:<br />

25% more pre-cut films per package than other brands<br />

dust proof anti static packaging<br />

lot number tracking system<br />

rolls, pre-cut circles & sheets<br />

Part No. Description Thickness<br />

pm<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

Packaging<br />

TF-025 Microporous Roll 6,4cm x 5,1m<br />

TF-112 Mylar 12 Roll 7,6cm x 91,4m<br />

TF-115 Ultrapolyester 1,5 Roll 7,6cm x 91,4m<br />

TF-125 Mylar 2,5 Roll 7,6cm x 91,4m<br />

Liquid Analysis 2<br />

Thin Films 2.2<br />

TF-125-345 Mylar 2,5 Square 7,6cm x 7,6cm (500 pcs.)<br />

TF-12560 PolyRep (replacement for<br />

polycarbonate)<br />

Mylar 2,5 + PP 6,0 2 Rolls a 7,6cm x 91,4m<br />

TF-1335 Hostaphan 3,5 Roll 7,6cm x 91,4m<br />

TF-1335-345 Hostaphan 3,5 Square 7,6cm x 7,6cm (500 pcs.)<br />

TF-135 Mylar 3,5 Roll 7,6cm x 91,4m<br />

TF-135-255 Mylar 3,5 Circle 6,4cm (500 pcs.)<br />

TF-135-345 Mylar 6,0 Square 7,6cm x 7,6cm (500 pcs.)<br />

TF-160 Mylar 6,0 Roll 7,6cm x 91,4m<br />

TF-160-255 Mylar 6,0 Circle 6,4cm (500 pcs.)<br />

TF-160-345 Mylar 6,0 Square 7,6cm x 7,6cm (500 pcs.)<br />

TF-212 Polypropylene 12,0 Roll 7,6cm x 91,4m<br />

TF-212-345 Polypropylene 12,0 Square 7,6cm x 7,6cm (500 pcs.)<br />

TF-240 Polypropylene 4,0 Roll 7,6cm x 91,4m<br />

TF-240-255 Polypropylene 4,0 Circle 6,4cm (500 pcs.)<br />

TF-240-30 Polypropylene 4,0 Circle 7,6cm (100 pcs.)<br />

TF-240-345 Polypropylene 4,0 Square 7,6cm x 7,6cm (500 pcs.)<br />

TF-250 Polypropylene 5,0 Roll 7,6cm x 91,4m<br />

TF-260 Polypropylene 6,0 Roll 7,6cm x 91,4m<br />

TF-260-255 Polypropylene 6,0 Circle 6,4cm (500 pcs.)<br />

TF-260-345 Polypropylene 6,0 Square 7,6cm x 7,6cm (500 pcs.)<br />

TF-350 Polycarbonate 5,0 Roll 7,6cm x 91,4m<br />

TF-475 Kapton 7,5 Roll 7,6cm x 91,4m<br />

TF-475-345 Kapton 7,5 Square 7,6cm x 7,6cm (500 pcs.)<br />

TF-500 XRF Tape Roll 25mm x 66m<br />

TF-LS-240-255 Polypropylene Low Sulfur 4,0 Circle 6,4cm (500 pcs.)<br />

13


14<br />

2 Liquid Analysis<br />

2.2 Thin Films<br />

Thin Films<br />

Part No. Description measurement<br />

WZ-0001 Preparation tool for our sample cups 56 x 20 mm<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com


3 Solid analysis<br />

3.1 Press<br />

3.1.1 Pellet Dies<br />

3.1.2 Rings<br />

3.1.3 Aluminium Cups<br />

3.1.4 Pellet Films<br />

3.1.5 Binding Additives for XRF-Analysis<br />

3.2 Mill<br />

3.2.1 Grinding<br />

3.2.2 Mixing<br />

15


16<br />

3 Solid Analysis<br />

3.1 Press<br />

Press<br />

Manual and electric hydraulic presses<br />

The preparation of solid pellets requires a hydraulic press<br />

and an appropriate die. Stable pellets can be prepared<br />

from a loose powder, using an aluminium cap or binder<br />

material.<br />

Usual diameters for XRF are 32 and 40mm. Considering that<br />

pressure is force per surface area it is recommended to use<br />

at least 15 tons for 32mm and 25 tons for 40mm.<br />

Specifications<br />

Max pressure 15 / 25 tons, electrical 25 / 40 tons<br />

Pressure display 0-20t / 0-30t / 0-40t<br />

Piston 108mm<br />

Bolster Screw diameter 30mm<br />

Bolster Screw Travel max 90mm<br />

Minimum distance between pressing faces 35mm<br />

Maximum distance between pressing faces 125mm<br />

Area size D310 x W290mm<br />

Weight 50,5kg, electrical 60kg<br />

Additional specs for electrical press: Push button to start the pressing<br />

process with an automatic switch off when the pre-defined pressure is reached.<br />

Manual release of pressure.<br />

Part No. Description<br />

PR-15* Hydraulic press 15 tons manual<br />

PR-25* Hydraulic press 25 tons manual<br />

PR-25a* Hydraulic press 25 tons electric<br />

PR-40 Hydraulic press 40 tons electric<br />

* for pelletizing a die is required additionally<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com


Pellet Dies<br />

Evacuable Pellet Die<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

Solid analysis 3<br />

Pellet Dies 3.1.1<br />

The Dies are designed for use with our Hydraulic Presses.<br />

Halide disks for infrared analysis are usually produced with the smaller size dies.<br />

The larger size dies are commonly used in briquetting samples for XRF and XRD<br />

analysis and many other industrial applications.<br />

All of the dies are equipped with nitrile O-ring seals and 2 pellets in between the sample is pressed.<br />

There is a wide range of 440C hardened stainless steel Evacuable Pellet Dies,<br />

used for compacting powdered samples into disks or briquettes.<br />

Part No. Description Diameter of pellets<br />

produced<br />

PR-L33000 Evacuable pellet die 13mm<br />

PR-CD-6008 Die with 2 pellets and piston 8mm<br />

PR-CD-6012 Die with 2 pellets and piston 12mm<br />

PR-CD-6016 Die with 2 pellets and piston 16mm<br />

PR-CD-6020 Die with 2 pellets and piston 20mm<br />

PR-CD-6024 Die with 2 pellets and piston 24mm<br />

PR-CD-6027 Die with 2 pellets and piston 27mm<br />

PR-CD-6032 Die with 2 pellets and piston 32mm<br />

PR-CD-6032R** Die with 2 pellets, piston and stamp out tool<br />

Pressed samples of 32mm in a ring with a OD of 40mm<br />

32mm<br />

PR-CD-6040 Die with 2 pellets and piston 40mm<br />

PR-SSP-61xx* Spare pellets xx<br />

We offer nearly every diameter. Please ask for a quotation.<br />

* Please choose the needed size<br />

** For the ring please have a look at part no. PR-CD-6032RingM (page 18 )<br />

Filling tool for boric acid pellets<br />

Part No. Description<br />

PR-CD-BA32 Filling tool boric acid 32<br />

PR-CD-BA40 Filling tool boric acid 40<br />

Especially for low quantities of samples a boric acid<br />

backing might be a solution.<br />

To place the sample in the center we offer a special<br />

tool to pour the sample into the die.<br />

A piston helps to press before filling the boric acid on top.<br />

17


18<br />

3 Solid Analysis<br />

3.1.2 Rings<br />

Used for manual and automatic sample handling<br />

Robust design<br />

Part No. Dimensions Quantity<br />

WZ-0002<br />

Outerdiameter 51.5mm<br />

Innerdiameter 35mm<br />

Height 8.6mm<br />

Groove outside of 2.5mm<br />

PR-CD-6032RingM* Outerdiameter 40mm<br />

Innerdiameter 32mm<br />

Height 14mm<br />

* Suitable for PR-CD-6032R (page 17)<br />

Rings for pellets<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

1<br />

1


Aluminium Cups<br />

Aluminium cups are used to stabilize your sample from 2 sides.<br />

However for a successful use the sample must show at least some binding properties.<br />

Another advantage of this method is the possibility of labeling and sucking with autosamplers.<br />

Part No. Description Quantity<br />

AC-530-1 Alu cups straight wall 30mm x 8mm for 31mm pellets 1.000 pcs.<br />

AC-538-6 Alu cups straight wall 38,5mm x 9,5mm for 40mm pellets 600 pcs.<br />

AC-532-1 Alu cups taper wall 31mm x 7,9mm for 32mm pellets 1.000 pcs.<br />

AC-540-6 Alu cups taper wall 39,8mm x 9,2mm for 40mm pellets 600 pcs.<br />

AC-550-6 Alu cups taper wall for 40mm x 7mm for 40mm pellets 600 pcs.<br />

Pellet films<br />

32mm and 40mm<br />

The use of the new pelletfilm allows also to press polymers using<br />

a standard die and press. It is not necessary to buy a hot press.<br />

Part No. Description Diameter of fi lms<br />

produced*<br />

PF-32500 Pellet film 500 circles 32mm<br />

PF-40500 Pellet film 500 circles 40mm<br />

Other diameters on request<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

Solid Analysis 3<br />

Aluminium Cups 3.1.3<br />

Pellet films 3.1.4<br />

19


20<br />

3 Solid Analysis<br />

3.1.5 Binding additives for XRF analysis<br />

Binding additives for XRF analysis<br />

Not all samples can be pelletized using Aluminium cups. They may be unstable or the<br />

aluminium cups effect the result. In such a case a binding material can be used.<br />

The most common is Hoechstwax HWC, available as a loose powder.<br />

Alternatively, a high performance “multimix” binder is available, in tablet form,<br />

producing highly stable and durable pellets. It is important to mix the binder well<br />

with the sample using a suitable mill. Contact us for information on appropriate<br />

mills for your application.<br />

Powders Wax Pellet<br />

If you have only a small amount of sample material a stable pellet can be made by<br />

using boric acid at the back of the sample. The boric acid is poured into the die first<br />

and then the sample is added on top. During pressing the boric acid forms a<br />

stable backing to the sample.<br />

Wax is good for the preparation of <strong>reference</strong> samples or calibration standards.<br />

Important is a good homogeneous mixture between wax and your sample.<br />

Multimix is good for the preperation of cement, raw meal, clinker, sand, etc.<br />

You just add 2-3 pellets before milling your sample and you will get a nice stable<br />

dustfree pellet.<br />

Part No. Description Quantity<br />

BM-0001-1 Boric acid p.A. powder 1 kg<br />

BM-0001-5 Boric acid p.A. powder 5 kg<br />

BM-0002-1 Hoechstwax* powder for XRF 250 g<br />

BM-0003-1 Cellulose C20 tabletts a 0,33g 1 kg<br />

BM-0003-5 Cellulose C20 tabletts a 0,33g 5 kg<br />

BM-0003-powder Powder 500 g<br />

PXR-225 Multimix tabletts a 0,25g 125 g<br />

PXR-225-1k Multimix tabletts a 0,25g 1 kg<br />

* Hoechstwax is a binder which forms very stable pellets. It is particularly good for<br />

preparing recalibration samples and standards.<br />

+<br />

4.0g 0.9g<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com


Mill<br />

Part No. Description Quantity<br />

MU-RMM200-220V Mixer Mill MM200 for 220-240V, 50/60Hz 1<br />

MU-RMM400 Mixer Mill MM400 for 100-240V, 50/60Hz 1<br />

Accessories<br />

Grinding for MU-RMM200-220V<br />

Part No. Description Quantity<br />

MU-RMM200-M25ZRO Grinding jar of Zirconia 25ml 1<br />

MU-RMM200-MK20ZRO Grinding ball 20mm of Zirconia 1<br />

Grinding for MU-RMM400<br />

Part No. Description Quantity<br />

MU-RMM400-MZr35 Grinding jar of Zirconia 35ml 1<br />

MU-RMM400-MK25ZRO Grinding ball 25mm of Zirconia 1<br />

MU-RMM400-MWC25 Grinding jar of tungsten carbide 25ml 1<br />

MU-RMM400-KWC20 Grinding ball 20mm of tungsten carbide 1<br />

Mixing<br />

Part No. Description Quantity<br />

MU-RMM200-MPS Mixing container Polystyrene 28ml Set=100 pcs.<br />

MU-RMM200-KPA5 Mixing ball Polyamide 5mm 1<br />

MU-RMM200-KPA7 Mixing ball Polyamide 7mm 1<br />

MU-RMM200-KPA9 Mixing ball Polyamide 9mm 1<br />

MU-RMM200-KPA12,7 Mixing ball Polyamide 12,7mm 1<br />

Other mills with accessories on request.<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

Solid Analysis 3<br />

Mill 3.2<br />

Accessories for grinding and mixing 3.2.1<br />

21


22<br />

Fusion technique 4<br />

Vulcan fusion machines 4.1<br />

Platinum ware 4.2<br />

High purity molten fluxes 4.3<br />

Sample storage boxes for XRF 4.4


Vulcan fusion machines<br />

The first fusion machine to have<br />

automating temperature settings.<br />

The fusion technique is used to improve precision<br />

over pressed powder techniques.<br />

No manual adjustment of flames<br />

Full microprocessor control<br />

Applications with variable temperature setting possible<br />

High flexibility for all types of applications<br />

Storage of 10 different programs<br />

VULCAN 2MA, 4MA, 6MA, 21/22MA XRF/ICP<br />

Technical Data Vulcan<br />

2MA<br />

Number of burners:<br />

Voltage:<br />

Power:<br />

Permiss. air pressure:<br />

Permiss. natural gas press.:<br />

Permiss. propane gas press.:<br />

Permiss oxygen gas press.:<br />

Air consumption:<br />

Oxygen consumption:<br />

Natural gas consumption:<br />

or liquid propane gas:<br />

Lenght:<br />

Width:<br />

Height:<br />

Weight:<br />

Vulcan<br />

4MA<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

2<br />

110-230 /50 Hertz<br />

170 W<br />

max. 6 bar<br />

22-60 mbar<br />

50 mbar<br />

max. 6 bar<br />

max.1 m 3/hr<br />

max. 0,5m 3/hr at 3 bar<br />

max. 0.66 m 3/hr<br />

max. 0,5m 3/hr at 3 bar<br />

600 mm<br />

530 mm<br />

300 mm<br />

~ 40 kg<br />

Vulcan<br />

6MA<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

4<br />

110-230 /50 Hertz<br />

210 W<br />

max. 6 bar<br />

22-60 mbar<br />

50 mbar<br />

max. 6 bar<br />

max.1 m 3/hr<br />

max. 0,5m 3/hr at 3 bar<br />

max. 0.66 m 3/hr<br />

max. 0,5m 3/hr at 3 bar<br />

600 mm<br />

530 mm<br />

300 mm<br />

~ 40 kg<br />

6<br />

110-230 /50 Hertz<br />

210 W<br />

max. 6 bar<br />

22-60 mbar<br />

50 mbar<br />

max. 6 bar<br />

max.1 m 3/hr<br />

max. 0,5m 3/hr at 3 bar<br />

max. 0.66 m 3/hr<br />

max. 0,5m 3/hr at 3 bar<br />

600 mm<br />

530 mm<br />

300 mm<br />

~ 40 kg<br />

Samples per h: 5-7 8-10 16-20 8-10<br />

* Please ask for our PTFE beaker (part no. FS-0007)<br />

Other versions on request<br />

Depending on requirements, we can offer machines<br />

from 2 to 6 positions. Therefore users can benefit from our<br />

applications database if they prepare only a few beads<br />

per month or 200 per day.<br />

Fusion technique 4<br />

Vulcan fusion machines 4.1<br />

21/22MA<br />

XRF/ICP*<br />

4<br />

110-230 /50 Hertz<br />

210 W<br />

max. 6 bar<br />

22-60 mbar<br />

50 mbar<br />

max. 6 bar<br />

max.1 m 3/hr<br />

max. 0,5m 3/hr at 3 bar<br />

max. 0.66 m 3/hr<br />

max. 0,5m 3/hr at 3 bar<br />

600 mm<br />

530 mm<br />

300 mm<br />

~ 40 kg<br />

Vulcan MA<br />

Vulcan 21/22MA XRF/ICP<br />

FLUXANA offers a full range of fusion machines in cooperation with HD-Elektronik.<br />

23


24<br />

4 Fusion technique<br />

4.2 Platinum ware<br />

We supply platinum ware made from platinum/gold 95/5 for our fusion machines.<br />

We accept old platinum ware for recycling as credit against your next order.<br />

We offer all platinum ware also in FKS.<br />

This surface finishing increases the lifetime of your crucibles and moulds.<br />

Please ask for a quote.<br />

Part No. Description OD<br />

mm<br />

ID<br />

mm<br />

Platinum ware<br />

Accessories for Vulcan<br />

2MA, 4MA, 6MA, 21/22MA XRF/ICP<br />

Height<br />

mm<br />

Bottom<br />

mm<br />

Weight<br />

g<br />

FS-OT866 Crucible Vulcan 34 20 38 0,5 45<br />

FS-OT867 Crucible Vulcan 36 22,5 38 0,5 51<br />

FS-OA434 Mould* 31 29 3 0,8 31<br />

FS-OA877 Mould* 34 32 3 0,8 31<br />

FS-OA438 Mould* 36 34 3 0,8 45<br />

FS-OA439 Mould* 41 39 3 0,8 46<br />

FS-OT26 XRF Crucible for muffel furnace** 35 40 25<br />

For your order in platinum FKS just add 'FKS' to the part no!<br />

* The dimensions D top and D bottom define the dimensions of the bead.<br />

The outer width of the squared mould is 51mm.<br />

** Volume ca. 30ml<br />

Other diameters on request.<br />

All platinum ware is made from platinum/gold 95%/5%. Other alloy on request.<br />

General accessories<br />

Part No. Composition Quantity<br />

FS-OZ327 Crucible tongs from V2A steel, shoes of platinum, length 230mm, ca 3g Pt 1<br />

FS-US Ultrasonic bath with heating, Vol. ca. 1.8l for cleaning 1<br />

FS-AB0001 Hood for VULCAN incl. Fan 1<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com


High purity molten fluxes<br />

Anhydrous homogeneous pre-fused fluxes with<br />

a low loss on ignition and defined granulometry.<br />

Non hygroscopic<br />

Non dusty<br />

Special mixtures and fluxes on request.<br />

Article No. Composition W/W% Melting<br />

point ⁰C<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

Quantity<br />

FX-X100 Lithiumtetraborate 100 920 2kg<br />

FX-X65 Lithiumtetraborate : Lithiummetraborate 66 : 34 875 2kg<br />

FX-X50 Lithiumtetraborate : Lithiummetraborate 50 : 50 850 2kg<br />

FX-X35 Lithiumtetraborate : Lithiummetraborate 35,3 : 64.7 (1.2 : 2.2) 825 2kg<br />

FX-X20 Lithiumtetraborate : Lithiummetraborate 20 : 80 840 2kg<br />

FX-X00 Lithiummetraborate 100 845 2kg<br />

FX-X90 Lithiumtetraborate : Lithium Fluorid 90 : 10 780 1kg<br />

Customer specific mixtures are available<br />

Purity*: >99.98%<br />

Loss on ignition: < 0.5%<br />

Granulometry: 100-600µm<br />

Density: 1.3<br />

Prefused, non hygroscopic<br />

*Each batch is analysed and a report available on request.<br />

Fusion technique 4<br />

High purity molten fluxes 4.3<br />

25


26<br />

Sample Storage 5


Sample Storage<br />

It is important to keep <strong>reference</strong> <strong>materials</strong>, prepared as beads or<br />

pellets in a dust free and dry environment. There is a wide range<br />

of boxes and containers for single or multiple samples and<br />

standards for XRF.<br />

If you cannot find what you want, please contact us.<br />

Part No. Description Compartments Qty/Set<br />

BX-0001-18 Box 210x120x35mm with lid 18x max 32mm pellets/cups 1<br />

BX-0001-24 Box 210x120x35mm with lid 24x max 32mm pellets/cups 1<br />

BX-0002-5 Drawer cabinet with 5 drawers, each<br />

with 42 partitions for D max 34mm,<br />

H 17mm (ideal for pellets D max 34mm)<br />

BX-0003-5 Drawer cabinet with 5 drawers, each<br />

with 25 partitions for D max 42mm,<br />

H 17mm (ideal for pellets D max 42mm)<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com<br />

210x max 34mm pellets 1<br />

125x max 42mm pellets 1<br />

BX-0004-39 Box for single pellet H 15mm max 32mm pellets 1<br />

BX-0004-46 Box for single pellet H 16mm max 40mm pellets 1<br />

BX-0004-46-6 Box for single pellet H 6mm max 46mm pellets 1<br />

BX-0004-50 Box for single pellet H 25mm max 50mm pellets 1<br />

BX-0005-6 Drawer cabinet with 6 drawers, each<br />

with 16 partitions for D max 55mm, H 16mm<br />

96x max55mm pellets 1<br />

BX-0006-P Plastic tweezers for beads 1<br />

BX-0007-1 Dessiccator W520 x H340 x D375mm 1<br />

BX-0007-2 Dessiccator W585 x H560 x D555mm 1<br />

WZ-0004 Handling tool for glass beads and pellets 1<br />

Additional, individual drawers to add the cabinet are available in various colours.<br />

Other dimensions on request.<br />

For storing your beads and pellets we would recommend:<br />

BX-0004-39 / BX-0004-46 / BX-0004-50 / BX-0004-46-6:<br />

Store 32mm (40mm) samples in these transparent boxes with sealed lid.<br />

BX-0005-6:<br />

Drawer cabinet with 16 partitions per drawer for storing boxes<br />

BX-0004-39 and BX-0004-46.<br />

The cabinet can be expanded with further drawers.<br />

BX-0002-5, BX-0003-5:<br />

Drawer cabinets suitable for direct storage of non-hygroscopic samples.<br />

Tip: Use our tool WZ-0004 to handle your pellets and beads and<br />

avoid finger contact.<br />

Sample Storage 5<br />

27


28<br />

6 FLUXANA <strong>certified</strong> <strong>reference</strong> <strong>materials</strong><br />

Your specialist for XRF:<br />

The application packages we offer include<br />

<strong>reference</strong> <strong>materials</strong> (RM). Our goal is to give<br />

you our longterm experience of calibration<br />

for x-ray fluorescence analysis.<br />

Producer of <strong>reference</strong> <strong>materials</strong>:<br />

To give you excellent support we work directly<br />

with the producers of RM worldwide.<br />

<strong>Fluxana</strong> <strong>certified</strong> <strong>reference</strong> <strong>materials</strong><br />

Catalog Description<br />

Products:<br />

Petrochemical <strong>reference</strong> <strong>materials</strong><br />

Liquid RM for AAS/ICP and XRF<br />

Organic Materials<br />

Alloys<br />

Fine chemicals<br />

Catalogs:<br />

Please ask for our separate catalogs available<br />

in printed form and as PDF-File.<br />

Aluminium<br />

This catalog gives you an overview of <strong>certified</strong> Aluminium<br />

<strong>reference</strong> <strong>materials</strong> supplied as disks,<br />

blocks or chips.<br />

Metals<br />

This catalog gives you an overview of <strong>certified</strong> metal <strong>reference</strong><br />

<strong>materials</strong> supplied as disks, blocks or chips.<br />

Minerals / Plastics / XRF monitors<br />

This catalog contains:<br />

Minerals / Ores<br />

Plastics<br />

XRF drift monitors<br />

pure chemicals.<br />

Petro standards liquid (ICP / XRF / IRRM)<br />

This catalog contains:<br />

sulfur in oil<br />

sulfur in gasoline<br />

lubricants<br />

wear metals<br />

metal concentrates<br />

Catalog rohs plastic 2007<br />

BCR 680 and new <strong>materials</strong> for ABS plastic<br />

now available!<br />

Waterbased standards for AA and ICP<br />

This catalog gives an overview of liquid <strong>reference</strong><br />

<strong>materials</strong> used for ICP / ICP-MS, IC and AA:<br />

ICP / ICP-MS standards<br />

EPA standards<br />

Ion chromatography standards<br />

Atomic absorption standards<br />

FLUXANA GmbH & Co. KG | Sommerdeich 22 | D-47533 Kleve | Germany<br />

Tel.: +49 (0) 2821 97 38 75 | Fax: +49 (0) 2821 97 38 76 | E-mail: info@fl uxana.de | Web: www.fl uxana.com


FLUXANA GmbH & Co. KG<br />

Sommerdeich 22, D-47533 Kleve, Germany<br />

Tel.: +49 (0) 2821 97 38 75<br />

Fax: +49 (0) 2821 97 38 76<br />

E-mail: info@fl uxana.de<br />

Web: www.fl uxana.com<br />

Amtsgericht Kleve: HR-A 2935, HR-B 8211<br />

Ust-IdNr.: DE 814692564, Steuer-Nr. 116/5755/0442<br />

Finanzamt Kleve<br />

In cooperation with:<br />

HD Elektronik und Elektrotechnik GmbH<br />

Sommerdeich 22, D-47533 Kleve, Germany<br />

Tel.: +49 (0) 2821 148 10<br />

Fax: +49 (0) 2821 148 09<br />

E-mail: hde@hdelektronik.de<br />

Web: www.hdelektronik.de<br />

Amtsgericht Kleve: HR-B 2162<br />

Ust-IdNr.: DE 812941185, Steuer-Nr. 116/5707/1869<br />

Finanzamt Kleve<br />

Official agent

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!