<strong>LOXON</strong> <strong>Specifications</strong><br />

1.07 WARRANTY<br />

A. UNIVERSAL full 21 year material warranty is available upon request and shall be subject to the following<br />

terms and conditions.<br />

1. The <strong>LOXON</strong> system shall be applied in accordance with manufacturer's specifications.<br />

2. Any claim must be promptly submitted to the manufacturer in writing.<br />

PART II - PRODUCTS<br />

2.01 - GENERAL<br />

A. All components of The <strong>LOXON</strong> Panel System shall be obtained from UNIVERSAL or their authorized distributor.<br />

B. No substitution or addition of other materials shall be permitted.<br />

2.02 MATERIALS<br />

A. The <strong>LOXON</strong> Panel Metal<br />

1. Shall be manufactured from one of the following materials.<br />

a. Minimum 0.008" thickness galvanized metal.<br />

b. Minimum 0.12" thickness alumin.<br />

c. Minimum G-60" thickness galvanized metal.<br />

B. Brick<br />

1. Kiln-fired 1/2" nominal thickness.<br />

2. UNIVERSAL THIN BRICK SYSTEMS INC<br />

a. Minimum compression strength of 1000 PSI when tested in accordance with ASTM C-513.<br />

b. Must pass the freeze thaw test described in ASTM C-666.<br />

C. Adhesive as approved by UNIVERSAL.<br />

1. A high-solid solvent based adhesive that remains flexible and unaffected by freeze-thaw cycles.<br />

D. Fastener as approved by UNIVERSAL.<br />

1. A corrosion resistant type specifically designed for the particular substrate where they are to be used.<br />

E. Mortar<br />

1. For proper workability, the mortar should be mixed to the consistency of a thick milkshake.<br />

2. Mixed to manufacturer's latest specifications when using bulk materials.<br />

3. A premixed mortar as approved by UNIVERSAL.<br />

F. Insulation Board<br />

1. Shall be produced by a manufacturer approved by UNIVERSAL.<br />

2. Shall meet current UNIVERSAL specifications.<br />

3. Maximum Flame spread and Smoke Development, when tested in accordance with ASTM E-84, shall<br />

not exceed 25 and 450 respectively.<br />

4. Maximum thickness used shall be no greater than 2" and meet local building code requirements.<br />

G. Water<br />

1. Shall be clean, potable and free of all foreign matter.<br />

H. Sheathing<br />

1. Plywood or OSB board shall be no less than 1/2" thick, minimum 4 ply APA Exposure or Exterior<br />

grade CD or better.<br />

2. APA spacing recommendations for edge and end joints must be followed.<br />

I. Moisture Barrier<br />

1. Tyvek, Tyuek Stucco wrap, <strong>Inc</strong>a Therm, R-warp or other equivilant building wrap<br />

2. Felt paper<br />

J. Light Gauge Steel Framing<br />

1. Shall include stud, track, bridging and bracing.<br />

2. Shall be galvanized or painted with rust-resistant primer.<br />

3. Minimum thickness shall be 20 gauge and as determined by loads and handling methods.<br />

K. Sealant Systems<br />

1. The sizing of expansion joints, as well as selection of the sealant to be used, shall be the responsibility<br />

of the Architect and/or Engineer.<br />

2. Sealants must be compatible with The <strong>LOXON</strong> System components.<br />

3. Other Sealant Systems shall be jointly approved in writing by the Architect, UNIVERSAL and the<br />

Sealant Manufacturer prior to installation.<br />

4. Color shall be as selected by the Architect.<br />