FRP Concentrate
FRP Concentrate
FRP Concentrate
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SUREWALL ®F R P C o n c e n t r a t eDESCRIPTION: A fiberglass-reinforced stucco concentrateFactory prepared mixture of portland cement, glass fibers,and proprietary ingredientsSpecified sand is added at the job siteCan be installed up to 5/8" (16mm) in one applicationUSES:As a stucco base, apply <strong>FRP</strong> <strong>Concentrate</strong> over:Masonry, concrete, metal lath or stucco netting.Lath or stucco netting is applied over:Building paper or continuous sheathingEPS applied over building paper—framing spacing isapproximately 16" (40cm) on centerCOMPOSITION:Binder: Portland cementFiller: Glass fibers—add specified sand at job siteColor: GreyKEY PHYSICAL PROPERTIES:Meets code criteria for exterior cementitious coating.ICBO ES Report # ER 4226 includes 1-hour fire-resistiveassemblies
F R P C o n c e n t r a t eCOVERAGE:Depending on the condition of substrateand the thickness of application,approximate coverages are:At 3/8" (9.5mm): 80 ft 2 (7.3m 2 ) perbag.At 5/8" (16mm): 50 ft 2 (4.6m 2 ) perbag.At 3/4" (19mm): 40 ft 2 (3.6m 2 ) perbag.PACKAGING:80 lb (36 kg) net weight in a multiwall,water-resistant bag.Storage: Store off ground and protectfrom rain and moisture.Shelf life: Six months if protectedfrom sun, freezing and moisture.WORKING TIME:Sets in 30–45 minutes after mixing,depending on conditions.Job nameC o n t r a c t o rD a t eSubmittal Appro v a l s :(Stamps or Signature s )SURFACE PREPARATION: On masonry and concrete apply onlyto surfaces that are sound, clean, dry,unpainted, and free of any residuewhich may affect the ability of <strong>FRP</strong><strong>Concentrate</strong> to bond to the surface.On lathed construction, apply tolathing installed in accordance withASTM C 1063. Cover wood-basedsheathings with two layers of “10minute” or one layer of “60 minute”grade D building paper. Othersheathed substrates require one layerof “10 minute” Grade D paper.Do not apply to substrates which arefrozen or contain frost or ice.Apply to surface prepared as for portlandcement plaster.MIXING:Start with approximately 3 gallons ofclean potable water. Add approximately60 lb of the ASTM C 897sand. Add one bag of Surewall <strong>FRP</strong><strong>Concentrate</strong>. Add remaining sandalong with additional water - approximately1–3 gallons for workability.Total amount of sand equals200–240 lb. Allow the material toslake then break set. If needed, addwater for workability.Use cool, clean water; let hose run toclear it of hot water.Sand: Sample and test in accordancewith ASTM C144, and gradewithin the following limits*:No. 4 -- 0No. 8 0 10No. 18 10 40No. 30 30 65No. 50 70 90No. 100 95 100*Retained on U.S. Standard Sieve. Percent retainedby weight + 2%.No additives of any kind, such asPortland cement, lime, rapid binders,antifreeze, accelerators, etc. shouldbe added under any circumstances.APPLICATION: Apply by hand trowel or plaster gun toa minimum 3/8" (9.5mm) thickness.The maximum thickness applied inone pass is 5/8" (16mm).For portland cement–based stuccofinish, lightly moisten the surface of<strong>FRP</strong> <strong>Concentrate</strong> before application.Texture may be applied as soon asbase has set sufficiently to receive it.<strong>FRP</strong> <strong>Concentrate</strong> should be keptmoist by fogging with water for atleast 24 hours after application, orlonger in dry weather.Start light fogging after initial set of1–2 hours.Allow <strong>FRP</strong> <strong>Concentrate</strong> to dry thoroughlybefore applying acrylic primersor finishes.LIMITATIONS: All <strong>FRP</strong> <strong>Concentrate</strong> materialsdescribed should not be applied ifambient temperatures cannot be keptabove 35°F (2°C) during applicationand drying periods. Prior to installation,the wall should be free of residualmoisture.For installation in temperatures lessthan 35°F, supplementary heat mustbe provided.<strong>FRP</strong> <strong>Concentrate</strong> should not beapplied if ambient temperature willexceed 120°F (49°C) within 24 hoursof application.Protect plaster from uneven andexcessive evaporation during hot, dryweather.Architectural Sales, I nc.143 S. Franklin St., Chagrin Falls, OH 44022 • Phone: Toll Free 888-888-7273 Local 440-247-4070 • Fax 440-247-4069Website: www.resarch.com • Email: sales@resarch.com