3.5 P5557.13 Mass Flow System<br />
3.5.1 Features<br />
• Differential pressure to monitor flow<br />
• Pressure and temperature sensors<br />
• Installed using an orifice plate between pipe flanges for convenient installation<br />
and servicing<br />
• Intrinsically safe for use in Group I and II hazardous areas<br />
3.5.2 Specification<br />
Measuring range:<br />
Dependent upon calibration of orifice<br />
plate<br />
Operating temperature: Up to 50°C<br />
3.6 P5557.10 Dual Pump Controller<br />
3.6.1 Features<br />
The <strong>TX6400</strong> Methane Recovery Monitoring System is equipped with two<br />
intrinsically safe pumps located within the gas monitoring chamber to ensure a<br />
constant flow of gas is applied to the gas sensors. These pumps should only be<br />
powered by the P5557.10 Dual Pump Controller.<br />
LED Off:<br />
LED Green:<br />
LED Red:<br />
Pump switched Off<br />
Pump running and healthy<br />
Pump fail<br />
www.trolex.com<br />
<strong>TX6400</strong>-UM-EN-01 13