<strong>UWA</strong> <strong>Engineering</strong> <strong>Pte</strong> LTd<br />

Tube & Wire Thermocouple Sensors


RTD Style "0"<br />

E<br />

RTD Style "C"<br />

1. Sheath Diameter (inch)<br />

1 = 3 / 16<br />

3 = 1 / 8<br />

5 = 1 / 4<br />

2. Lead Wire Construction<br />

G2 = PFA Teflon 2 wire<br />

G3 = PFA Teflon 3 wire<br />

U P T<br />

3. Sheath Length (mm)<br />

001 to 999<br />

Lengths over 999mm consult factory<br />

RTD Style "T"<br />

L<br />

4. Wire Length (meter)<br />

Lengths over 10 meter, consult factory<br />

(For wire length in Feet, please refer below chart)<br />

L<br />

5. RTD Style<br />

0 = Std Insulated Leads<br />

C = Plug or Jack<br />

T = Metal Transitions<br />

6. Terminations / Options<br />

A = Standard male plug<br />

B = Standard female jack<br />

C = Standard plug with mating connector<br />

F = Miniature male plug<br />

G = Miniature female jack<br />

H = Miniature plug with mating connector<br />

T = Standard, 1 1/2 inch split leads<br />

U = 1 1/2 inch split leads with spade lugs<br />

Durable rigid sheath<br />

. 316 stainless steel<br />

-70 to 204 o C<br />

Wire Length in Feet<br />

A = 0 B = 1 C = 2 D = 3 E = 4<br />

F = 5 G = 6 H = 7 J = 8 K = 9<br />

Example : 4 Feet = AE , 15 Feet = BF


Adjustable Spring<br />

1 2<br />

1<br />

3 4 5 6 7 8 9 10<br />

U A - - B<br />

1. Construction Style<br />

1 = Standard Cap - 6 inch spring<br />

2 = Standard Cap - 12 inch spring<br />

3 = 12mm Cap - 6 inch spring<br />

4 = 15mm Cap - 6 inch spring<br />

5 = 12mm Cap - 12 inch spring<br />

6 = 15mm cap - 12 inch spring<br />

1 = 3 / 16<br />

A = Fibreglass (24 gauge stranded)<br />

D = Fibreglass (20 gauge stranded)<br />

B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />

E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />

J = PFA with stainless steel overbraid (24 gauge stranded)<br />

N = PFA with stainless steel overbraid (20 gauge stranded)<br />

G = PFA (24 gauge stranded)<br />

M = PFA (20 gauge stranded)<br />

B = Grounded, round tip<br />

A = Grounded, flat tip<br />

C = Grounded, drill point<br />

D = Grounded, round tip, dual element<br />

F = Ungrounded, round tip<br />

E = Ungrounded, flat tip<br />

H = Ungrounded, drill point<br />

J = Ungrounded, round tip, dual element<br />

Whole inches: 006 to 999<br />

Lengths over 999 inches, consult factory<br />

B = 1<br />

2. Sheath Diameter (inch)<br />

3. Lead Protection<br />

4. Junction<br />

5-7. Lead Length (inches)<br />

8. Sheath length (inch)<br />

9. Terminations / Options<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

10. Calibration<br />

1 = Type J<br />

2 = Type K<br />

3 = Type T<br />

4 = Type E


Flexible Extensions<br />

1 2 3 4 5 6 7 8 9 10<br />

U E 1 X - X<br />

-<br />

1. Construction Style<br />

1 = Flexible Extensions<br />

2. Diameter<br />

X = Not Applicable<br />

3. Lead Protection<br />

A = Fibreglass (24 gauge stranded)<br />

D = Fibreglass (20 gauge stranded)<br />

G = PFA (24 gauge stranded)<br />

M = PFA (20 gauge stranded)<br />

B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />

E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />

J = PFA with stainless steel overbraid (24 gauge stranded)<br />

N= PFA wirh stainless steel overbraid (20 gauge stranded)<br />

F = Fibreglass with stainless steel hose (20 gauge stranded)<br />

K = PFA with stainless steel hose (24 gauge stranded)<br />

P = PFA with stainless steel hose (20 gauge stranded)<br />

4. Junction<br />

X = Not applicable<br />

5-7. Lead Length (inches)<br />

Whole inches: 006 to 999<br />

Lengths over 999 inches, consult factory<br />

8. Termination "A"<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

9. Termination "B"<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

10. Calibration<br />

1 = Type J 3 = Type T<br />

2 = Type K 4 = Type E<br />

**Not available with SS hose.


Flange Style<br />

1 2 3 4 5 6 7 8 9 10<br />

U F 1 - -<br />

1 = Thermocouple with Flange<br />

1 = 3 / 16<br />

3 = 1 / 8<br />

5 = 1 / 4<br />

A = Fibreglass (24 gauge stranded)<br />

* D = Fibreglass (20 gauge stranded)<br />

G = PFA (24 gauge stranded)<br />

* M = PFA (20 gauge stranded)<br />

B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />

* E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />

J = PFA with stainless steel overbraid (24 gauge stranded)<br />

* N = PFA wirh stainless steel overbraid (20 gauge stranded)<br />

C = Fibreglass with stainless steel hose (24 gauge stranded)<br />

* F = Fibreglass with stainless steel hose (20 gauge stranded)<br />

K = PFA with stainless steel hose (24 gauge stranded)<br />

* P = PFA with stainless steel hose (20 gauge stranded)<br />

B = Grounded, round tip<br />

E = Ungrounded, flat tip<br />

A = Grounded, flat tip<br />

H = Ungrounded, drill point<br />

C = Grounded, drill point<br />

J = Ungrounded, round tip, dual element<br />

* D = Grounded, round tip, dual element K = Exposed<br />

F = Ungrounded, round tip<br />

Whole inches: 006 to 999<br />

Lengths over 999 inches, consult factory<br />

D = 2 H = 4 M = 6 R = 8 W = 10<br />

E = 2 1 / 2 J = 4 1 / 2 N = 6 1 / 2 S = 8 1 / 2 Y = 11<br />

F = 3 K = 5 P = 7 T = 9 Z = 12<br />

G = 3 1 / 2 L = 5 1 / 2 Q = 7 1 / 2 V = 9 1 / 2<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

1 = Type J<br />

2 = Type K<br />

3 = Type T<br />

4 = Type E<br />

**Not available with 1/8 inch diameter sheath.<br />

1. Construction Style<br />

2. Sheath Diameter (inch)<br />

3. Lead Protection<br />

4. Junction<br />

5-7. Lead Length (inches)<br />

8. "B" Dimension (inches)<br />

9. Terminations / Options<br />

10. Calibration


Grommet Style<br />

1 2 3 4 5 6 7 8 9 10<br />

U G 1 X - G<br />

-<br />

1. Construction Style<br />

1 = Grommet Thermocouple<br />

2. Diameter<br />

X = Not Applicable<br />

3. Lead Protection<br />

H = Fibreglass (24 gauge solid)<br />

Q = PFA (24 gauge solid)<br />

4. Junction<br />

G = Grounded<br />

5-7. Lead Length (inches)<br />

Whole inches: 006 to 999<br />

Lengths over 999 inches, consult factory<br />

8. Grommet Size (inch)<br />

A = 0.195 inch I.D X 0.375 inch OD X 0.035 inch thick<br />

9. Terminations / Options<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

10. Calibration<br />

1 = Type J 3 = Type T<br />

2 = Type K 4 = Type E


Insulated Wire Thermocouple<br />

1 2 3 4 5 6 7 8<br />

U H 1 X - K - X<br />

9 10<br />

1. Construction Style<br />

1 = Series 61<br />

2. Diameter<br />

X = Not Applicable<br />

3. Lead Protection<br />

H = Fiberhlass (24 gauge solid)<br />

S = Fiberglass (20 gauge solid)<br />

W = Fiberglass with SS overbraid (24 gauge solid)<br />

T = Fiberglass with SS overbraid (20 gauge solid)<br />

U = Extruded FEP (20 gauge solid)<br />

Y = Extruded FEP (24 gauge solid)<br />

4. Junction<br />

K = Exposed<br />

5-7. Lead Length (inches)<br />

Whole inches: 006 to 999<br />

8. Enter X<br />

9. Terminations<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

10. Calibration<br />

1 = Type J<br />

2 = Type K<br />

3 = Type T


Rigid Sheath ( 1 / 8 and 3 / 16 inch Diameter)<br />

1 2 3 4 5 6 7 8 9 10<br />

U R - -<br />

1. Construction Style<br />

1 = Plain sheath, straight<br />

2 = Plain sheath, 45 o bend<br />

3 = Plain sheath. 90 o bend<br />

2. Sheath Diameter (inch)<br />

1 = 3 / 16<br />

3 = 1 / 8<br />

5 = 1 / 4<br />

3. Lead Protection<br />

A = Fibreglass (24 gauge stranded)<br />

* D = Fibreglass (20 gauge stranded)<br />

G = PFA (24 gauge stranded)<br />

* M = PFA (20 gauge stranded)<br />

B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />

* E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />

J = PFA with stainless steel overbraid (24 gauge stranded)<br />

* N = PFA with stainless steel overbraid (20 gauge stranded)<br />

C = Fibreglass with stainless steel hose (24 gauge stranded)<br />

* F = Fibreglass with stainless steel hose (20 gauge stranded)<br />

K = PFA with stainless steel hose (24 gauge stranded)<br />

* P = PFA with stainless steel hose (20 gauge stranded)<br />

4. Junction<br />

B = Grounded, round tip<br />

A = Grounded, flat tip<br />

C = Grounded, drill point<br />

D = Grounded, round tip, dual element<br />

F = Ungrounded, round tip<br />

5-7. Lead Length (inches)<br />

Whole inches: 006 to 999<br />

8. "A" Dimension (inch)<br />

E = Ungrounded, flat tip<br />

H = Ungrounded, drill point<br />

J = Ungrounded, round tip, dual element<br />

K = Exposed<br />

A = 1 / 2 E = 2 1 / 2 J = 4 1 / 2 N = 6 1 / 2 S = 8 1 / 2 Y = 11<br />

B = 1 F = 3 K = 5 P = 7 T = 9 Z = 12<br />

C = 1 1 / 2 G = 3 1 / 2 L = 5 1 / 2 Q = 7 1 / 2 V = 9 1 / 2<br />

D = 2 H = 4 M = 6 R = 8 W = 10<br />

9. Terminations / Options<br />

**Not available with 1/8 inch diameter<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

10. Calibration<br />

1 = Type J<br />

2 = Type K<br />

3 = Type T<br />

4 = Type E


Rigid Sheath With Threaded Fitting ( 1 / 8 and 3 / 16 inch Diameter)<br />

1 2 3 4 5 6 7 8 9 10<br />

U R - -<br />

1. Construction Style<br />

4 = Straight Sheath with 1 / 8 " NPT SS Fitting<br />

5 = Straight Sheath with 1 / 2 " NPT SS Fitting<br />

2. Sheath Diameter (inch)<br />

1 = 3 / 16<br />

3 = 1 / 8<br />

5 = 1 / 4<br />

3. Lead Protection<br />

A = Fibreglass (24 gauge stranded)<br />

* D = Fibreglass (20 gauge stranded)<br />

G = PFA (24 gauge stranded)<br />

* M = PFA (20 gauge stranded)<br />

B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />

* E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />

J = PFA with stainless steel overbraid (24 gauge stranded)<br />

* N = PFA with stainless steel overbraid (20 gauge stranded)<br />

C = Fibreglass with stainless steel hose (24 gauge stranded)<br />

* F = Fibreglass with stainless steel hose (20 gauge stranded)<br />

K = PFA with stainless steel hose (24 gauge stranded)<br />

* P = PFA with stainless steel hose (20 gauge stranded)<br />

4. Junction<br />

B = Grounded, round tip<br />

A = Grounded, flat tip<br />

C = Grounded, drill point<br />

D = Grounded, round tip, dual element<br />

F = Ungrounded, round tip<br />

5-7. Lead Length (inches)<br />

Whole inches: 006 to 999<br />

Lengths over 999 inches, consult factory<br />

8. "B" Dimension (inch)<br />

E = Ungrounded, flat tip<br />

H = Ungrounded, drill point<br />

J = Ungrounded, round tip, dual element<br />

K = Exposed<br />

A = 1 / 2 E = 2 1 / 2 J = 4 1 / 2 N = 6 1 / 2 S = 8 1 / 2 Y = 11<br />

B = 1 F = 3 K = 5 P = 7 T = 9 Z = 12<br />

C = 1 1 / 2 G = 3 1 / 2 L = 5 1 / 2 Q = 7 1 / 2 U = 9 1 / 2<br />

D = 2 H = 4 M = 6 R = 8 W = 10<br />

9. Terminations / Options<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

10. Calibration<br />

1 = Type J<br />

2 = Type K<br />

3 = Type T<br />

4 = Type E<br />

**Not available with 1/8 inch diameter sheath.


Rigid Sheath Fixed Bayonet Style<br />

1 2 3 4 5 6 7 8 9 10<br />

U R - -<br />

6 = Bayonet cap with springm, straight<br />

7 = Bayonet caop with spring, 45 o bend<br />

8 = Bayonet cap with spring, 90 o bend<br />

1 = 3 / 16<br />

3 = 1 / 8<br />

5 = 1 / 4<br />

**Not available with 1/8 inch diameter sheath.<br />

1. Construction Style<br />

2. Sheath Diameter (inch)<br />

3. Lead Protection<br />

A = Fibreglass (24 gauge stranded)<br />

* D = Fibreglass (20 gauge stranded)<br />

G = PFA (24 gauge stranded)<br />

* M = PFA (20 gauge stranded)<br />

B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />

* E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />

J = PFA with stainless steel overbraid (24 gauge stranded)<br />

* N = PFA wirh stainless steel overbraid (20 gauge stranded)<br />

C = Fibreglass with stainless steel hose (24 gauge stranded)<br />

* F = Fibreglass with stainless steel hose (20 gauge stranded)<br />

K = PFA with stainless steel hose (24 gauge stranded)<br />

* P = PFA with stainless steel hose (20 gauge stranded)<br />

4. Junction<br />

B = Grounded, round tip<br />

E = Ungrounded, flat tip<br />

A = Grounded, flat tip<br />

H = Ungrounded, drill point<br />

C = Grounded, drill point<br />

J = Ungrounded, round tip, dual element<br />

* D = Grounded, round tip, dual element K = Exposed<br />

F = Ungrounded, round tip<br />

5-7. Lead Length (inches)<br />

Whole inches: 006 to 999<br />

Lengths over 999 inches, consult factory<br />

8. "B" Dimension (inches)<br />

D = 2 G = 3 1 / 2 K = 5 N = 6 1 / 2 R = 8 V = 9 1 / 2 Z = 12<br />

E = 2 1 / 2 H = 4 L = 5 1 / 2 P = 7 S = 8 1 / 2 W = 10<br />

F = 3 J = 4 1 / 2 M = 6 Q = 7 1 / 2 T = 9 Y = 11<br />

9. Terminations / Options<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

10. Calibration<br />

1 = Type J 3 = Type T<br />

2 = Type K 4 = Type E


Ring Terminal Style<br />

1 2 3 4 5 6 7 8 9 10<br />

U T 1 X - -<br />

1. Construction Style<br />

1 = Ring Terminal Thermocouple<br />

2. Diameter<br />

X = Not Applicable<br />

3. Lead Protection<br />

A = Fibreglass (24 gauge stranded)<br />

D = Fibreglass (20 gauge stranded)<br />

G = PFA (24 gauge stranded)<br />

M = PFA (20 gauge stranded)<br />

B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />

E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />

J = PFA with stainless steel overbraid (24 gauge stranded)<br />

N= PFA wirh stainless steel overbraid (20 gauge stranded)<br />

4. Junction<br />

G = Grounded<br />

U = Ungrounded<br />

5-7. Lead Length (inches)<br />

Whole inches: 006 to 999<br />

Lengths over 999 inches, consult factory<br />

8. Stud Size - Hole Dia (inches)<br />

* A = No. 6<br />

* B = No. 8<br />

* C = No. 10<br />

9. Terminations / Options<br />

0.144<br />

0.169<br />

0.196<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

10. Calibration<br />

1 = Type J 3 = Type T<br />

2 = Type K 4 = Type E<br />

**Not available with 24 guage wire.


Nozzle Terminal Style<br />

1 2 3 4 5 6 7 8 9 10<br />

U T 2 X - G<br />

-<br />

1. Construction Style<br />

2 = Nozzle Thermocouple<br />

2. Diameter<br />

X = Not Applicable<br />

3. Lead Protection<br />

A = Fibreglass (24 gauge stranded)<br />

D = Fibreglass (20 gauge stranded)<br />

G = PFA (24 gauge stranded)<br />

M = PFA (20 gauge stranded)<br />

B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />

E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />

J = PFA with stainless steel overbraid (24 gauge stranded)<br />

N= PFA wirh stainless steel overbraid (20 gauge stranded)<br />

4. Junction<br />

G = Grounded<br />

5-7. Lead Length (inches)<br />

Whole inches: 006 to 999<br />

Lengths over 999 inches, consult factory<br />

8. 304 SS, Bolt Size<br />

A = 1 / 4 inch X 28 UNF, 3 / 8 inch thread depth<br />

M = M6 X 1<br />

9. Terminations / Options<br />

A = Standard, 2 1 / 2 inch split leads<br />

B = 2 1 / 2 inch split leads with #6 spade lugs<br />

D = Standard male plug, quick disconnect<br />

E = Standard female Jack, quick disconnect<br />

F = Miniature male plug, quick disconnect<br />

H = Miniature female Jack, quick disconnect<br />

10. Calibration<br />

**Not available with 24 guage wire.<br />

1 = Type J 3 = Type T<br />

2 = Type K 4 = Type E


Thermocouples<br />

Connection Head<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

U 6 - - 0 0 0<br />

3. Sheath O.D. (inch)<br />

E = 0.063 G = 0.188 J = 0.313 L = 0.500<br />

F = 0.125 H = 0.250 K = 0.375<br />

4. Connection Heat<br />

1 = Explosion proof<br />

2 = Minature plastic<br />

3 = Small cast iron<br />

4 = Small aluminum<br />

5 = Polypropylene<br />

6 = Universal cast iron<br />

7 = Universal cast aluminium<br />

~ 5. Head Mounting Fittings and Optional Weld Pads<br />

A = Single threaded 303 SS<br />

B = Single threaded 303 SS with series 2 weld pad<br />

C = Single threaded 303 SS with series 5 weld pad<br />

D = Double threaded 303 SS 1/2" NPT<br />

F = Spring loaded double threaded 316 SS 1/2" NPT<br />

6. Sheath Material<br />

1 = 304 SS 2 = 310 SS 3 = 316 SS 4 = Alloy 600<br />

~ 5 = PFA coated over 304 SS sheath<br />

7-8. Sheath Length "L" (whole inches)<br />

01 to 99 (Lengths over 99 inches consult workshop)<br />

9. Sheath Length "L" (fractional inch)<br />

A = 0 C = 1/4 E = 1/2 G = 3/4<br />

B = 1/8 D = 3/8 F = 5/8 H = 7/8<br />

10. Junction<br />

Grounded Ungrounded Exposed<br />

Single U W<br />

A<br />

Dual, common G S<br />

K<br />

Dual, isolated - B<br />

D<br />

11. Special Requirements<br />

If none, enter "0". If other required, consult workshop<br />

12-14. Enter "000"<br />

15. Calibration<br />

Standard Limits<br />

Special Limits<br />

J K T E N<br />

3 4 8 2 -<br />

~ Double threaded fitting options are not available with minature plastic head.


Thermocouples<br />

For Use with Thermowells<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

U 8 - - 0 0<br />

3. Sheath O.D. (inch)<br />

F = 0.125 G = 0.188 H = 0.250<br />

4. Connection Heat<br />

1 = Explosion proof<br />

(1/2 inch NPT and 3/4 inch NPT thermocouple opening only)<br />

3 = Small cast iron<br />

5 = Polypropylene (1/2 inch NPT thermocouple opening only)<br />

6 = Universal cast iron<br />

7 = Universal cast aluminium<br />

5. Cold End Configuration<br />

A = Type A, no extensions<br />

B = Type B, 3-inch nipple<br />

C = Type C, 4-inch nipple-union<br />

D = Type D, 6-inch nipple-union-nipple<br />

Note : Steel nipple and unions are standard<br />

6. Sheath Material<br />

1 = 304 SS 3 = 316 SS 4 = Alloy 600<br />

7-8. Sheath Length "L" (see drawings)<br />

When orderinng a complete assembly with thermowell,<br />

specify "U6" as required. Otherwise, specify the "L" dimension in whole inches.<br />

9. Sheath Length "L" (fractional inch)<br />

A = Not required, complete assembly<br />

B = 1/8 D = 3/8 F = 5/8 H = 7/8<br />

C = 1/4 E = 1/2 G = 3/4<br />

10. Junction<br />

Grounded Ungrounded<br />

Single U W<br />

Dual, common G S<br />

Dual, isolated - B<br />

11. Spring-Loading<br />

1 = Yes 2 = No<br />

12. Special Requirements<br />

If none, enter "0". If other required, consult workshop<br />

13-14. Enter "00"<br />

15. Calibration<br />

Standard Limits J K T E N<br />

Special Limits 3 4 8 2 -<br />

* Not available in dual element


Thermocouples<br />

Cut and Stripped<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

U 1 - - 0 0<br />

3. Sheath O.D. (inch)<br />

D = 0.040<br />

E = 0.063<br />

F = 0.125<br />

G = 0.188<br />

H = 0.250<br />

4. Fittings, Weld Pads<br />

0 = None<br />

J = Non-Adjustable Compression Brass<br />

L = NonAdjustable Compression SS<br />

5. Sheath Material<br />

4 = Alloy 600<br />

6 - 7. Sheath Length "L" (whole inches)<br />

01 to 99<br />

Lengths over 99 inches consult workshop<br />

8. Sheath Length "L" (fractional inch)<br />

A = 0 E = 1/2<br />

B = 1/8 F = 5/8<br />

C = 1/4 G = 3/4<br />

D = 3/8 H = 7/8<br />

9. Junction<br />

Grounded<br />

Single<br />

U<br />

Dual, common G<br />

Dual, isolated -<br />

Ungrounded<br />

W<br />

S<br />

B<br />

10. Strip Length "S" (whole inches)<br />

0 to 3<br />

1 inch maximum on 0.040 and smaller<br />

11. Strip Length "S" (fractional inch)<br />

A = 0 E = 1/2<br />

B = 1/8 F = 5/8<br />

C = 1/4 G = 3/4<br />

D = 3/8 H = 7/8<br />

12. Special Requirements<br />

If none, enter "0". If required, consult workshop<br />

13-14. Enter "00"<br />

15. Calibration<br />

Standard Limits<br />

Special Limits<br />

J K T E N<br />

3 4 8 2 -


Thermocouples<br />

Metal Transition<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

U 9 0 - -<br />

2. Style<br />

9 = Miniature metal transition w/149degC potting<br />

3. Sheath O.D. (inch)<br />

D = 0.040<br />

E = 0.063<br />

4. Leadwire Construction<br />

Standard<br />

Fiberglass Solid A<br />

FEP Solid D<br />

5. Enter "0"<br />

6. Leadwire Termination<br />

A = Standard male plug<br />

B = Standard female jack<br />

C = Standard plug with mating connector<br />

F = Miniature plug<br />

G = Miniature female jack<br />

H = Miniature plug with mating connector<br />

T = Standard, 1 1/2 inch split leads<br />

U = 1 1/2 inch split leads with spade lugs<br />

7. Sheath Material<br />

1 = 304 SS 3 = 316 SS 4 = Alloy 600<br />

8-9. Sheath Length "L" (whole inches)<br />

01 to 99 (Lengths over 99 inches consult workshop)<br />

Maximum length for PFA coating is 48 inches.<br />

10. Sheath Length "L" (fractional inch)<br />

A = 0 C = 1/4 E = 1/2 G = 3/4<br />

B = 1/8 D = 3/8 F = 5/8 H = 7/8<br />

11. Junction<br />

Grounded Ungrounded<br />

Single U W<br />

12-13. Leadwire Length "E" (whole feet)<br />

01 to 30 (01 foot standard)<br />

14. Special Requirements<br />

0 = None<br />

15. Calibration<br />

Standard Limits<br />

Special Limits<br />

J K<br />

3 4<br />

# 1000 o F potting not recommended with FEP insulated wire.


Ti:er::r*c*r:g:l*s<br />

Metal Transitions with Spring Strain Relief<br />

[t<br />

H<br />

TH<br />

IH<br />

IH<br />

IH<br />

IE<br />

I<br />

E<br />

I<br />

lt<br />

I<br />

ilt<br />

I F<br />

lu<br />

lft<br />

Il<br />

lll<br />

LL]<br />

Metal Transitions<br />

with Spring Strain<br />

2. Style<br />

3 = Metal transition with strain relief<br />

3. Sheath O.D. (inch/MM)<br />

D=0.040 F=0.125 H=0.250<br />

E=0063 G=0.188 M=1.5MM<br />

4. Leadwire Construction<br />

Standard WSS Overbraid<br />

FiberglassSolid A B<br />

FEP Solid D E<br />

FiberglassStranded G H<br />

FEP Stranded K L<br />

FiberglassKapton<br />

P<br />

5. Fittings, Weld Pads<br />

0 = None<br />

J = Non-Adjustable Compression Brass<br />

L = NonAdjustable Compression SS<br />

6. Leadwire Termination<br />

A = Standard male plug<br />

B = Standard female jack<br />

C = Standard plug with mating connector<br />

F = Miniature plug<br />

G = Miniature female jack<br />

H = Miniature plug with mating connector<br />

T = Standard, 1 l12inch split leads<br />

U = 1 112 inch split leads with spade lugs<br />

7. Sheath Material<br />

4 = Alloy 60<br />

5 = PFA coated over 304 SS sheath<br />

8-9. Sheath Length "L"(whole<br />

inches)<br />

01 to 99 (Lengths over 99 inches consult workshop)<br />

Maximum length for PFA coating is 48 inches.<br />

1 2 3<br />

U 3<br />

___i<br />

T II<br />

w/Flex Armor<br />

/.<br />

10. Sheath Length "L"(fractional<br />

inch)<br />

A=0 c=1t4 E=1t2 G=3t4 J=28t29 L = 1O/11<br />

B=1/B D=3/B F=5/8 H=7t8 K=17t18 X=C/F<br />

F<br />

J<br />

M<br />

4 5 6 7 8 I 10 1112 1314 15<br />

11. Junction<br />

Single<br />

Dual, common<br />

Dual. isolated<br />

Grounded Ungrounded<br />

U W<br />

G S<br />

- B<br />

Exposed<br />

A<br />

K<br />

D<br />

12-13. Leadwire Length "E"(whole<br />

feet)<br />

01 to 99 (01 foot standard)<br />

lf none, enter "0". lf required, consult workshop<br />

14. Special Requirements<br />

O = Standard 3OOoF<br />

15. Calibration<br />

Standard Limits<br />

Special Limits<br />

J K T<br />

3 4 8<br />

E<br />

2<br />

N<br />

PFA coating only available on sheath O.D. -> E, F, G, H.<br />

Stranded leadwire available only for sheath O.D. 0.063 to 0.500 inch<br />

1000'F potting not recommended with FEP insulated wire.


Thermocouples<br />

Plug or Jack Termination<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

U 2 - - 0 0 0<br />

3. Sheath O.D. (inch)<br />

D = 0.040 G = 0.188<br />

E = 0.063 H = 0.250<br />

F = 0.125<br />

Note: PFA coating only available on E, F, G, H.<br />

4. Connector Type<br />

Standard Plugs and Jacks 400 o F (200 o C)<br />

(0.313 inch maximum O.D.)<br />

A = Standard plug<br />

B = Standard jack<br />

C = Standard plug with mating connector<br />

Miniature Plugs and Jacks 400 o F (200 o C)<br />

(0.125 inch maximum O.D.)<br />

F = Miniature plug<br />

G = Miniature jack<br />

H = Miniature plug with mating connector<br />

High Temperature Plugs and Jacks 1000 o F (540 o C)<br />

(0.250 inch maximum O.D.)<br />

L = High temperature plug<br />

M = High temperature jack<br />

N = High temperature plug with mating connector<br />

5. Fittings, Weld Pads<br />

0 = None<br />

J = Non-Adjustable Compression Brass<br />

L = NonAdjustable Compression SS<br />

6. Sheath Material<br />

4 = Alloy 600<br />

5 = PFA coated over 304 SS<br />

7 - 8. Sheath Length "L" (whole inches)<br />

01 to 99<br />

Lengths over 99 inches consult workshop<br />

Maximum length for PFA coating is 48 inches.<br />

9. Sheath Length "L" (fractional inch)<br />

A = 0 C = 1/4 E = 1/2G = 3/4<br />

B = 1/8 D = 3/8 F = 5/8H = 7/8<br />

10. Junction<br />

Grounded Ungrounded Exposed<br />

Single U W A<br />

Dual, common G S K<br />

Dual, isolated - B D<br />

11. Special Requirements<br />

If none, enter "0". If required, consult workshop<br />

12-14. Enter "000"<br />

15. Calibration<br />

Standard Limits<br />

Special Limits<br />

J K T E N<br />

3 4 8 2 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!