Download Product Brochure - UWA Engineering Pte Ltd
Download Product Brochure - UWA Engineering Pte Ltd
Download Product Brochure - UWA Engineering Pte Ltd
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>UWA</strong> <strong>Engineering</strong> <strong>Pte</strong> LTd<br />
Tube & Wire Thermocouple Sensors
RTD Style "0"<br />
E<br />
RTD Style "C"<br />
1. Sheath Diameter (inch)<br />
1 = 3 / 16<br />
3 = 1 / 8<br />
5 = 1 / 4<br />
2. Lead Wire Construction<br />
G2 = PFA Teflon 2 wire<br />
G3 = PFA Teflon 3 wire<br />
U P T<br />
3. Sheath Length (mm)<br />
001 to 999<br />
Lengths over 999mm consult factory<br />
RTD Style "T"<br />
L<br />
4. Wire Length (meter)<br />
Lengths over 10 meter, consult factory<br />
(For wire length in Feet, please refer below chart)<br />
L<br />
5. RTD Style<br />
0 = Std Insulated Leads<br />
C = Plug or Jack<br />
T = Metal Transitions<br />
6. Terminations / Options<br />
A = Standard male plug<br />
B = Standard female jack<br />
C = Standard plug with mating connector<br />
F = Miniature male plug<br />
G = Miniature female jack<br />
H = Miniature plug with mating connector<br />
T = Standard, 1 1/2 inch split leads<br />
U = 1 1/2 inch split leads with spade lugs<br />
Durable rigid sheath<br />
. 316 stainless steel<br />
-70 to 204 o C<br />
Wire Length in Feet<br />
A = 0 B = 1 C = 2 D = 3 E = 4<br />
F = 5 G = 6 H = 7 J = 8 K = 9<br />
Example : 4 Feet = AE , 15 Feet = BF
Adjustable Spring<br />
1 2<br />
1<br />
3 4 5 6 7 8 9 10<br />
U A - - B<br />
1. Construction Style<br />
1 = Standard Cap - 6 inch spring<br />
2 = Standard Cap - 12 inch spring<br />
3 = 12mm Cap - 6 inch spring<br />
4 = 15mm Cap - 6 inch spring<br />
5 = 12mm Cap - 12 inch spring<br />
6 = 15mm cap - 12 inch spring<br />
1 = 3 / 16<br />
A = Fibreglass (24 gauge stranded)<br />
D = Fibreglass (20 gauge stranded)<br />
B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />
E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />
J = PFA with stainless steel overbraid (24 gauge stranded)<br />
N = PFA with stainless steel overbraid (20 gauge stranded)<br />
G = PFA (24 gauge stranded)<br />
M = PFA (20 gauge stranded)<br />
B = Grounded, round tip<br />
A = Grounded, flat tip<br />
C = Grounded, drill point<br />
D = Grounded, round tip, dual element<br />
F = Ungrounded, round tip<br />
E = Ungrounded, flat tip<br />
H = Ungrounded, drill point<br />
J = Ungrounded, round tip, dual element<br />
Whole inches: 006 to 999<br />
Lengths over 999 inches, consult factory<br />
B = 1<br />
2. Sheath Diameter (inch)<br />
3. Lead Protection<br />
4. Junction<br />
5-7. Lead Length (inches)<br />
8. Sheath length (inch)<br />
9. Terminations / Options<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
10. Calibration<br />
1 = Type J<br />
2 = Type K<br />
3 = Type T<br />
4 = Type E
Flexible Extensions<br />
1 2 3 4 5 6 7 8 9 10<br />
U E 1 X - X<br />
-<br />
1. Construction Style<br />
1 = Flexible Extensions<br />
2. Diameter<br />
X = Not Applicable<br />
3. Lead Protection<br />
A = Fibreglass (24 gauge stranded)<br />
D = Fibreglass (20 gauge stranded)<br />
G = PFA (24 gauge stranded)<br />
M = PFA (20 gauge stranded)<br />
B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />
E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />
J = PFA with stainless steel overbraid (24 gauge stranded)<br />
N= PFA wirh stainless steel overbraid (20 gauge stranded)<br />
F = Fibreglass with stainless steel hose (20 gauge stranded)<br />
K = PFA with stainless steel hose (24 gauge stranded)<br />
P = PFA with stainless steel hose (20 gauge stranded)<br />
4. Junction<br />
X = Not applicable<br />
5-7. Lead Length (inches)<br />
Whole inches: 006 to 999<br />
Lengths over 999 inches, consult factory<br />
8. Termination "A"<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
9. Termination "B"<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
10. Calibration<br />
1 = Type J 3 = Type T<br />
2 = Type K 4 = Type E<br />
**Not available with SS hose.
Flange Style<br />
1 2 3 4 5 6 7 8 9 10<br />
U F 1 - -<br />
1 = Thermocouple with Flange<br />
1 = 3 / 16<br />
3 = 1 / 8<br />
5 = 1 / 4<br />
A = Fibreglass (24 gauge stranded)<br />
* D = Fibreglass (20 gauge stranded)<br />
G = PFA (24 gauge stranded)<br />
* M = PFA (20 gauge stranded)<br />
B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />
* E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />
J = PFA with stainless steel overbraid (24 gauge stranded)<br />
* N = PFA wirh stainless steel overbraid (20 gauge stranded)<br />
C = Fibreglass with stainless steel hose (24 gauge stranded)<br />
* F = Fibreglass with stainless steel hose (20 gauge stranded)<br />
K = PFA with stainless steel hose (24 gauge stranded)<br />
* P = PFA with stainless steel hose (20 gauge stranded)<br />
B = Grounded, round tip<br />
E = Ungrounded, flat tip<br />
A = Grounded, flat tip<br />
H = Ungrounded, drill point<br />
C = Grounded, drill point<br />
J = Ungrounded, round tip, dual element<br />
* D = Grounded, round tip, dual element K = Exposed<br />
F = Ungrounded, round tip<br />
Whole inches: 006 to 999<br />
Lengths over 999 inches, consult factory<br />
D = 2 H = 4 M = 6 R = 8 W = 10<br />
E = 2 1 / 2 J = 4 1 / 2 N = 6 1 / 2 S = 8 1 / 2 Y = 11<br />
F = 3 K = 5 P = 7 T = 9 Z = 12<br />
G = 3 1 / 2 L = 5 1 / 2 Q = 7 1 / 2 V = 9 1 / 2<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
1 = Type J<br />
2 = Type K<br />
3 = Type T<br />
4 = Type E<br />
**Not available with 1/8 inch diameter sheath.<br />
1. Construction Style<br />
2. Sheath Diameter (inch)<br />
3. Lead Protection<br />
4. Junction<br />
5-7. Lead Length (inches)<br />
8. "B" Dimension (inches)<br />
9. Terminations / Options<br />
10. Calibration
Grommet Style<br />
1 2 3 4 5 6 7 8 9 10<br />
U G 1 X - G<br />
-<br />
1. Construction Style<br />
1 = Grommet Thermocouple<br />
2. Diameter<br />
X = Not Applicable<br />
3. Lead Protection<br />
H = Fibreglass (24 gauge solid)<br />
Q = PFA (24 gauge solid)<br />
4. Junction<br />
G = Grounded<br />
5-7. Lead Length (inches)<br />
Whole inches: 006 to 999<br />
Lengths over 999 inches, consult factory<br />
8. Grommet Size (inch)<br />
A = 0.195 inch I.D X 0.375 inch OD X 0.035 inch thick<br />
9. Terminations / Options<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
10. Calibration<br />
1 = Type J 3 = Type T<br />
2 = Type K 4 = Type E
Insulated Wire Thermocouple<br />
1 2 3 4 5 6 7 8<br />
U H 1 X - K - X<br />
9 10<br />
1. Construction Style<br />
1 = Series 61<br />
2. Diameter<br />
X = Not Applicable<br />
3. Lead Protection<br />
H = Fiberhlass (24 gauge solid)<br />
S = Fiberglass (20 gauge solid)<br />
W = Fiberglass with SS overbraid (24 gauge solid)<br />
T = Fiberglass with SS overbraid (20 gauge solid)<br />
U = Extruded FEP (20 gauge solid)<br />
Y = Extruded FEP (24 gauge solid)<br />
4. Junction<br />
K = Exposed<br />
5-7. Lead Length (inches)<br />
Whole inches: 006 to 999<br />
8. Enter X<br />
9. Terminations<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
10. Calibration<br />
1 = Type J<br />
2 = Type K<br />
3 = Type T
Rigid Sheath ( 1 / 8 and 3 / 16 inch Diameter)<br />
1 2 3 4 5 6 7 8 9 10<br />
U R - -<br />
1. Construction Style<br />
1 = Plain sheath, straight<br />
2 = Plain sheath, 45 o bend<br />
3 = Plain sheath. 90 o bend<br />
2. Sheath Diameter (inch)<br />
1 = 3 / 16<br />
3 = 1 / 8<br />
5 = 1 / 4<br />
3. Lead Protection<br />
A = Fibreglass (24 gauge stranded)<br />
* D = Fibreglass (20 gauge stranded)<br />
G = PFA (24 gauge stranded)<br />
* M = PFA (20 gauge stranded)<br />
B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />
* E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />
J = PFA with stainless steel overbraid (24 gauge stranded)<br />
* N = PFA with stainless steel overbraid (20 gauge stranded)<br />
C = Fibreglass with stainless steel hose (24 gauge stranded)<br />
* F = Fibreglass with stainless steel hose (20 gauge stranded)<br />
K = PFA with stainless steel hose (24 gauge stranded)<br />
* P = PFA with stainless steel hose (20 gauge stranded)<br />
4. Junction<br />
B = Grounded, round tip<br />
A = Grounded, flat tip<br />
C = Grounded, drill point<br />
D = Grounded, round tip, dual element<br />
F = Ungrounded, round tip<br />
5-7. Lead Length (inches)<br />
Whole inches: 006 to 999<br />
8. "A" Dimension (inch)<br />
E = Ungrounded, flat tip<br />
H = Ungrounded, drill point<br />
J = Ungrounded, round tip, dual element<br />
K = Exposed<br />
A = 1 / 2 E = 2 1 / 2 J = 4 1 / 2 N = 6 1 / 2 S = 8 1 / 2 Y = 11<br />
B = 1 F = 3 K = 5 P = 7 T = 9 Z = 12<br />
C = 1 1 / 2 G = 3 1 / 2 L = 5 1 / 2 Q = 7 1 / 2 V = 9 1 / 2<br />
D = 2 H = 4 M = 6 R = 8 W = 10<br />
9. Terminations / Options<br />
**Not available with 1/8 inch diameter<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
10. Calibration<br />
1 = Type J<br />
2 = Type K<br />
3 = Type T<br />
4 = Type E
Rigid Sheath With Threaded Fitting ( 1 / 8 and 3 / 16 inch Diameter)<br />
1 2 3 4 5 6 7 8 9 10<br />
U R - -<br />
1. Construction Style<br />
4 = Straight Sheath with 1 / 8 " NPT SS Fitting<br />
5 = Straight Sheath with 1 / 2 " NPT SS Fitting<br />
2. Sheath Diameter (inch)<br />
1 = 3 / 16<br />
3 = 1 / 8<br />
5 = 1 / 4<br />
3. Lead Protection<br />
A = Fibreglass (24 gauge stranded)<br />
* D = Fibreglass (20 gauge stranded)<br />
G = PFA (24 gauge stranded)<br />
* M = PFA (20 gauge stranded)<br />
B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />
* E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />
J = PFA with stainless steel overbraid (24 gauge stranded)<br />
* N = PFA with stainless steel overbraid (20 gauge stranded)<br />
C = Fibreglass with stainless steel hose (24 gauge stranded)<br />
* F = Fibreglass with stainless steel hose (20 gauge stranded)<br />
K = PFA with stainless steel hose (24 gauge stranded)<br />
* P = PFA with stainless steel hose (20 gauge stranded)<br />
4. Junction<br />
B = Grounded, round tip<br />
A = Grounded, flat tip<br />
C = Grounded, drill point<br />
D = Grounded, round tip, dual element<br />
F = Ungrounded, round tip<br />
5-7. Lead Length (inches)<br />
Whole inches: 006 to 999<br />
Lengths over 999 inches, consult factory<br />
8. "B" Dimension (inch)<br />
E = Ungrounded, flat tip<br />
H = Ungrounded, drill point<br />
J = Ungrounded, round tip, dual element<br />
K = Exposed<br />
A = 1 / 2 E = 2 1 / 2 J = 4 1 / 2 N = 6 1 / 2 S = 8 1 / 2 Y = 11<br />
B = 1 F = 3 K = 5 P = 7 T = 9 Z = 12<br />
C = 1 1 / 2 G = 3 1 / 2 L = 5 1 / 2 Q = 7 1 / 2 U = 9 1 / 2<br />
D = 2 H = 4 M = 6 R = 8 W = 10<br />
9. Terminations / Options<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
10. Calibration<br />
1 = Type J<br />
2 = Type K<br />
3 = Type T<br />
4 = Type E<br />
**Not available with 1/8 inch diameter sheath.
Rigid Sheath Fixed Bayonet Style<br />
1 2 3 4 5 6 7 8 9 10<br />
U R - -<br />
6 = Bayonet cap with springm, straight<br />
7 = Bayonet caop with spring, 45 o bend<br />
8 = Bayonet cap with spring, 90 o bend<br />
1 = 3 / 16<br />
3 = 1 / 8<br />
5 = 1 / 4<br />
**Not available with 1/8 inch diameter sheath.<br />
1. Construction Style<br />
2. Sheath Diameter (inch)<br />
3. Lead Protection<br />
A = Fibreglass (24 gauge stranded)<br />
* D = Fibreglass (20 gauge stranded)<br />
G = PFA (24 gauge stranded)<br />
* M = PFA (20 gauge stranded)<br />
B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />
* E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />
J = PFA with stainless steel overbraid (24 gauge stranded)<br />
* N = PFA wirh stainless steel overbraid (20 gauge stranded)<br />
C = Fibreglass with stainless steel hose (24 gauge stranded)<br />
* F = Fibreglass with stainless steel hose (20 gauge stranded)<br />
K = PFA with stainless steel hose (24 gauge stranded)<br />
* P = PFA with stainless steel hose (20 gauge stranded)<br />
4. Junction<br />
B = Grounded, round tip<br />
E = Ungrounded, flat tip<br />
A = Grounded, flat tip<br />
H = Ungrounded, drill point<br />
C = Grounded, drill point<br />
J = Ungrounded, round tip, dual element<br />
* D = Grounded, round tip, dual element K = Exposed<br />
F = Ungrounded, round tip<br />
5-7. Lead Length (inches)<br />
Whole inches: 006 to 999<br />
Lengths over 999 inches, consult factory<br />
8. "B" Dimension (inches)<br />
D = 2 G = 3 1 / 2 K = 5 N = 6 1 / 2 R = 8 V = 9 1 / 2 Z = 12<br />
E = 2 1 / 2 H = 4 L = 5 1 / 2 P = 7 S = 8 1 / 2 W = 10<br />
F = 3 J = 4 1 / 2 M = 6 Q = 7 1 / 2 T = 9 Y = 11<br />
9. Terminations / Options<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
10. Calibration<br />
1 = Type J 3 = Type T<br />
2 = Type K 4 = Type E
Ring Terminal Style<br />
1 2 3 4 5 6 7 8 9 10<br />
U T 1 X - -<br />
1. Construction Style<br />
1 = Ring Terminal Thermocouple<br />
2. Diameter<br />
X = Not Applicable<br />
3. Lead Protection<br />
A = Fibreglass (24 gauge stranded)<br />
D = Fibreglass (20 gauge stranded)<br />
G = PFA (24 gauge stranded)<br />
M = PFA (20 gauge stranded)<br />
B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />
E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />
J = PFA with stainless steel overbraid (24 gauge stranded)<br />
N= PFA wirh stainless steel overbraid (20 gauge stranded)<br />
4. Junction<br />
G = Grounded<br />
U = Ungrounded<br />
5-7. Lead Length (inches)<br />
Whole inches: 006 to 999<br />
Lengths over 999 inches, consult factory<br />
8. Stud Size - Hole Dia (inches)<br />
* A = No. 6<br />
* B = No. 8<br />
* C = No. 10<br />
9. Terminations / Options<br />
0.144<br />
0.169<br />
0.196<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
10. Calibration<br />
1 = Type J 3 = Type T<br />
2 = Type K 4 = Type E<br />
**Not available with 24 guage wire.
Nozzle Terminal Style<br />
1 2 3 4 5 6 7 8 9 10<br />
U T 2 X - G<br />
-<br />
1. Construction Style<br />
2 = Nozzle Thermocouple<br />
2. Diameter<br />
X = Not Applicable<br />
3. Lead Protection<br />
A = Fibreglass (24 gauge stranded)<br />
D = Fibreglass (20 gauge stranded)<br />
G = PFA (24 gauge stranded)<br />
M = PFA (20 gauge stranded)<br />
B = Fibreglass with stainless steel overbraid (24 gauge stranded)<br />
E = Fibreglass with stainless steel overbraid (20 gauge stranded)<br />
J = PFA with stainless steel overbraid (24 gauge stranded)<br />
N= PFA wirh stainless steel overbraid (20 gauge stranded)<br />
4. Junction<br />
G = Grounded<br />
5-7. Lead Length (inches)<br />
Whole inches: 006 to 999<br />
Lengths over 999 inches, consult factory<br />
8. 304 SS, Bolt Size<br />
A = 1 / 4 inch X 28 UNF, 3 / 8 inch thread depth<br />
M = M6 X 1<br />
9. Terminations / Options<br />
A = Standard, 2 1 / 2 inch split leads<br />
B = 2 1 / 2 inch split leads with #6 spade lugs<br />
D = Standard male plug, quick disconnect<br />
E = Standard female Jack, quick disconnect<br />
F = Miniature male plug, quick disconnect<br />
H = Miniature female Jack, quick disconnect<br />
10. Calibration<br />
**Not available with 24 guage wire.<br />
1 = Type J 3 = Type T<br />
2 = Type K 4 = Type E
Thermocouples<br />
Connection Head<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
U 6 - - 0 0 0<br />
3. Sheath O.D. (inch)<br />
E = 0.063 G = 0.188 J = 0.313 L = 0.500<br />
F = 0.125 H = 0.250 K = 0.375<br />
4. Connection Heat<br />
1 = Explosion proof<br />
2 = Minature plastic<br />
3 = Small cast iron<br />
4 = Small aluminum<br />
5 = Polypropylene<br />
6 = Universal cast iron<br />
7 = Universal cast aluminium<br />
~ 5. Head Mounting Fittings and Optional Weld Pads<br />
A = Single threaded 303 SS<br />
B = Single threaded 303 SS with series 2 weld pad<br />
C = Single threaded 303 SS with series 5 weld pad<br />
D = Double threaded 303 SS 1/2" NPT<br />
F = Spring loaded double threaded 316 SS 1/2" NPT<br />
6. Sheath Material<br />
1 = 304 SS 2 = 310 SS 3 = 316 SS 4 = Alloy 600<br />
~ 5 = PFA coated over 304 SS sheath<br />
7-8. Sheath Length "L" (whole inches)<br />
01 to 99 (Lengths over 99 inches consult workshop)<br />
9. Sheath Length "L" (fractional inch)<br />
A = 0 C = 1/4 E = 1/2 G = 3/4<br />
B = 1/8 D = 3/8 F = 5/8 H = 7/8<br />
10. Junction<br />
Grounded Ungrounded Exposed<br />
Single U W<br />
A<br />
Dual, common G S<br />
K<br />
Dual, isolated - B<br />
D<br />
11. Special Requirements<br />
If none, enter "0". If other required, consult workshop<br />
12-14. Enter "000"<br />
15. Calibration<br />
Standard Limits<br />
Special Limits<br />
J K T E N<br />
3 4 8 2 -<br />
~ Double threaded fitting options are not available with minature plastic head.
Thermocouples<br />
For Use with Thermowells<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
U 8 - - 0 0<br />
3. Sheath O.D. (inch)<br />
F = 0.125 G = 0.188 H = 0.250<br />
4. Connection Heat<br />
1 = Explosion proof<br />
(1/2 inch NPT and 3/4 inch NPT thermocouple opening only)<br />
3 = Small cast iron<br />
5 = Polypropylene (1/2 inch NPT thermocouple opening only)<br />
6 = Universal cast iron<br />
7 = Universal cast aluminium<br />
5. Cold End Configuration<br />
A = Type A, no extensions<br />
B = Type B, 3-inch nipple<br />
C = Type C, 4-inch nipple-union<br />
D = Type D, 6-inch nipple-union-nipple<br />
Note : Steel nipple and unions are standard<br />
6. Sheath Material<br />
1 = 304 SS 3 = 316 SS 4 = Alloy 600<br />
7-8. Sheath Length "L" (see drawings)<br />
When orderinng a complete assembly with thermowell,<br />
specify "U6" as required. Otherwise, specify the "L" dimension in whole inches.<br />
9. Sheath Length "L" (fractional inch)<br />
A = Not required, complete assembly<br />
B = 1/8 D = 3/8 F = 5/8 H = 7/8<br />
C = 1/4 E = 1/2 G = 3/4<br />
10. Junction<br />
Grounded Ungrounded<br />
Single U W<br />
Dual, common G S<br />
Dual, isolated - B<br />
11. Spring-Loading<br />
1 = Yes 2 = No<br />
12. Special Requirements<br />
If none, enter "0". If other required, consult workshop<br />
13-14. Enter "00"<br />
15. Calibration<br />
Standard Limits J K T E N<br />
Special Limits 3 4 8 2 -<br />
* Not available in dual element
Thermocouples<br />
Cut and Stripped<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
U 1 - - 0 0<br />
3. Sheath O.D. (inch)<br />
D = 0.040<br />
E = 0.063<br />
F = 0.125<br />
G = 0.188<br />
H = 0.250<br />
4. Fittings, Weld Pads<br />
0 = None<br />
J = Non-Adjustable Compression Brass<br />
L = NonAdjustable Compression SS<br />
5. Sheath Material<br />
4 = Alloy 600<br />
6 - 7. Sheath Length "L" (whole inches)<br />
01 to 99<br />
Lengths over 99 inches consult workshop<br />
8. Sheath Length "L" (fractional inch)<br />
A = 0 E = 1/2<br />
B = 1/8 F = 5/8<br />
C = 1/4 G = 3/4<br />
D = 3/8 H = 7/8<br />
9. Junction<br />
Grounded<br />
Single<br />
U<br />
Dual, common G<br />
Dual, isolated -<br />
Ungrounded<br />
W<br />
S<br />
B<br />
10. Strip Length "S" (whole inches)<br />
0 to 3<br />
1 inch maximum on 0.040 and smaller<br />
11. Strip Length "S" (fractional inch)<br />
A = 0 E = 1/2<br />
B = 1/8 F = 5/8<br />
C = 1/4 G = 3/4<br />
D = 3/8 H = 7/8<br />
12. Special Requirements<br />
If none, enter "0". If required, consult workshop<br />
13-14. Enter "00"<br />
15. Calibration<br />
Standard Limits<br />
Special Limits<br />
J K T E N<br />
3 4 8 2 -
Thermocouples<br />
Metal Transition<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
U 9 0 - -<br />
2. Style<br />
9 = Miniature metal transition w/149degC potting<br />
3. Sheath O.D. (inch)<br />
D = 0.040<br />
E = 0.063<br />
4. Leadwire Construction<br />
Standard<br />
Fiberglass Solid A<br />
FEP Solid D<br />
5. Enter "0"<br />
6. Leadwire Termination<br />
A = Standard male plug<br />
B = Standard female jack<br />
C = Standard plug with mating connector<br />
F = Miniature plug<br />
G = Miniature female jack<br />
H = Miniature plug with mating connector<br />
T = Standard, 1 1/2 inch split leads<br />
U = 1 1/2 inch split leads with spade lugs<br />
7. Sheath Material<br />
1 = 304 SS 3 = 316 SS 4 = Alloy 600<br />
8-9. Sheath Length "L" (whole inches)<br />
01 to 99 (Lengths over 99 inches consult workshop)<br />
Maximum length for PFA coating is 48 inches.<br />
10. Sheath Length "L" (fractional inch)<br />
A = 0 C = 1/4 E = 1/2 G = 3/4<br />
B = 1/8 D = 3/8 F = 5/8 H = 7/8<br />
11. Junction<br />
Grounded Ungrounded<br />
Single U W<br />
12-13. Leadwire Length "E" (whole feet)<br />
01 to 30 (01 foot standard)<br />
14. Special Requirements<br />
0 = None<br />
15. Calibration<br />
Standard Limits<br />
Special Limits<br />
J K<br />
3 4<br />
# 1000 o F potting not recommended with FEP insulated wire.
Ti:er::r*c*r:g:l*s<br />
Metal Transitions with Spring Strain Relief<br />
[t<br />
H<br />
TH<br />
IH<br />
IH<br />
IH<br />
IE<br />
I<br />
E<br />
I<br />
lt<br />
I<br />
ilt<br />
I F<br />
lu<br />
lft<br />
Il<br />
lll<br />
LL]<br />
Metal Transitions<br />
with Spring Strain<br />
2. Style<br />
3 = Metal transition with strain relief<br />
3. Sheath O.D. (inch/MM)<br />
D=0.040 F=0.125 H=0.250<br />
E=0063 G=0.188 M=1.5MM<br />
4. Leadwire Construction<br />
Standard WSS Overbraid<br />
FiberglassSolid A B<br />
FEP Solid D E<br />
FiberglassStranded G H<br />
FEP Stranded K L<br />
FiberglassKapton<br />
P<br />
5. Fittings, Weld Pads<br />
0 = None<br />
J = Non-Adjustable Compression Brass<br />
L = NonAdjustable Compression SS<br />
6. Leadwire Termination<br />
A = Standard male plug<br />
B = Standard female jack<br />
C = Standard plug with mating connector<br />
F = Miniature plug<br />
G = Miniature female jack<br />
H = Miniature plug with mating connector<br />
T = Standard, 1 l12inch split leads<br />
U = 1 112 inch split leads with spade lugs<br />
7. Sheath Material<br />
4 = Alloy 60<br />
5 = PFA coated over 304 SS sheath<br />
8-9. Sheath Length "L"(whole<br />
inches)<br />
01 to 99 (Lengths over 99 inches consult workshop)<br />
Maximum length for PFA coating is 48 inches.<br />
1 2 3<br />
U 3<br />
___i<br />
T II<br />
w/Flex Armor<br />
/.<br />
10. Sheath Length "L"(fractional<br />
inch)<br />
A=0 c=1t4 E=1t2 G=3t4 J=28t29 L = 1O/11<br />
B=1/B D=3/B F=5/8 H=7t8 K=17t18 X=C/F<br />
F<br />
J<br />
M<br />
4 5 6 7 8 I 10 1112 1314 15<br />
11. Junction<br />
Single<br />
Dual, common<br />
Dual. isolated<br />
Grounded Ungrounded<br />
U W<br />
G S<br />
- B<br />
Exposed<br />
A<br />
K<br />
D<br />
12-13. Leadwire Length "E"(whole<br />
feet)<br />
01 to 99 (01 foot standard)<br />
lf none, enter "0". lf required, consult workshop<br />
14. Special Requirements<br />
O = Standard 3OOoF<br />
15. Calibration<br />
Standard Limits<br />
Special Limits<br />
J K T<br />
3 4 8<br />
E<br />
2<br />
N<br />
PFA coating only available on sheath O.D. -> E, F, G, H.<br />
Stranded leadwire available only for sheath O.D. 0.063 to 0.500 inch<br />
1000'F potting not recommended with FEP insulated wire.
Thermocouples<br />
Plug or Jack Termination<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
U 2 - - 0 0 0<br />
3. Sheath O.D. (inch)<br />
D = 0.040 G = 0.188<br />
E = 0.063 H = 0.250<br />
F = 0.125<br />
Note: PFA coating only available on E, F, G, H.<br />
4. Connector Type<br />
Standard Plugs and Jacks 400 o F (200 o C)<br />
(0.313 inch maximum O.D.)<br />
A = Standard plug<br />
B = Standard jack<br />
C = Standard plug with mating connector<br />
Miniature Plugs and Jacks 400 o F (200 o C)<br />
(0.125 inch maximum O.D.)<br />
F = Miniature plug<br />
G = Miniature jack<br />
H = Miniature plug with mating connector<br />
High Temperature Plugs and Jacks 1000 o F (540 o C)<br />
(0.250 inch maximum O.D.)<br />
L = High temperature plug<br />
M = High temperature jack<br />
N = High temperature plug with mating connector<br />
5. Fittings, Weld Pads<br />
0 = None<br />
J = Non-Adjustable Compression Brass<br />
L = NonAdjustable Compression SS<br />
6. Sheath Material<br />
4 = Alloy 600<br />
5 = PFA coated over 304 SS<br />
7 - 8. Sheath Length "L" (whole inches)<br />
01 to 99<br />
Lengths over 99 inches consult workshop<br />
Maximum length for PFA coating is 48 inches.<br />
9. Sheath Length "L" (fractional inch)<br />
A = 0 C = 1/4 E = 1/2G = 3/4<br />
B = 1/8 D = 3/8 F = 5/8H = 7/8<br />
10. Junction<br />
Grounded Ungrounded Exposed<br />
Single U W A<br />
Dual, common G S K<br />
Dual, isolated - B D<br />
11. Special Requirements<br />
If none, enter "0". If required, consult workshop<br />
12-14. Enter "000"<br />
15. Calibration<br />
Standard Limits<br />
Special Limits<br />
J K T E N<br />
3 4 8 2 -