05.07.2015 Views

SERVO-DRIVE for AVENTOS HK

SERVO-DRIVE for AVENTOS HK

SERVO-DRIVE for AVENTOS HK

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SERVO</strong>-<strong>DRIVE</strong> <strong>for</strong> <strong>AVENTOS</strong> <strong>HK</strong><br />

C<br />

A<br />

B<br />

B<br />

B<br />

B<br />

<strong>SERVO</strong>-<strong>DRIVE</strong> set<br />

Cover set<br />

A<br />

Set includes:<br />

■ Drive unit<br />

■ 60" universal cable<br />

■ Cable connector<br />

■ Cable end protector (qty 2)<br />

B<br />

Set includes:<br />

■ <strong>SERVO</strong>-<strong>DRIVE</strong> cover plate (left)<br />

■ Cover plate (right)<br />

■ Non-handed cover cap (qty 2)<br />

■ <strong>SERVO</strong>-<strong>DRIVE</strong> switches (qty 2)<br />

■ Ø5 mm Blum distance bumper (qty 4)<br />

■ Color: gray<br />

Part no.<br />

Part no.<br />

<strong>SERVO</strong>-<strong>DRIVE</strong> set<br />

21KA000<br />

Cover set<br />

21K8000.NA<br />

Subject to technical modifications without notice. © 2011<br />

14


Power supply set<br />

C<br />

Set includes:<br />

■ Power supply<br />

■ Wall mount bracket<br />

■ Three-prong power cord<br />

■ Cable connector<br />

■ Cable end protector (qty 3)<br />

■ Cable clips (qty 10)<br />

■ 19' universal cable<br />

■ Technical in<strong>for</strong>mation<br />

Power supply set<br />

Part no.<br />

Z10NE02UG10<br />

15


Electrical components<br />

<strong>SERVO</strong>-<strong>DRIVE</strong> power supply<br />

Components<br />

Supplies power to the drive units<br />

■ UL certified<br />

■ Can power up to 18 drive units<br />

■ Connect to switched GFCI outlet<br />

■ Cable length six feet<br />

NOTE: Three-prong power cord required<br />

Specifications<br />

Input specifications<br />

Input voltage<br />

Input frequency<br />

Input current<br />

Inrush current<br />

Protection class<br />

Earth leakage current<br />

Power factor<br />

100-240 VAC<br />

50-60 Hz<br />

2.00 A<br />

100 A maximum at 230 VAC<br />

Class I<br />

1.5 mA maximum<br />

compliant with EN61000-3-2<br />

General specifications<br />

Efficiency 85% typical<br />

Isolation 3000 VAC input to output, 2000 VAC input<br />

to groud — negative output is connected<br />

to ground<br />

Switching frequency<br />

60 kHz ± 10 kHz<br />

Output specifications<br />

Output voltage 24 VDC<br />

Output power max. 100 W<br />

Minimum load none<br />

Load regulation 2%<br />

Ripple and noise 1% peak-to-peak maximum measured with<br />

additional external capacitors at output:<br />

0.1 µF and 10 µF (electrolytic capacitor)<br />

Over voltage protection<br />

Overload protection<br />

Short circuit protection<br />

at 33 VDC<br />

120-150% hiccup trip and restart mode with<br />

auto recovery<br />

continuous<br />

Environmental in<strong>for</strong>mation<br />

Operating temprature 32 °F to 149 °F<br />

Storage temperature -4 °F to 185° F<br />

Protection IP40<br />

Space requirements and safety distance <strong>for</strong> power supply<br />

A safety distance of 30 mm must be maintained <strong>for</strong> air circulation.<br />

Subject to technical modifications without notice. © 2011<br />

16


Wiring options<br />

Wiring options<br />

For wall cabinets<br />

For <strong>SERVO</strong>-<strong>DRIVE</strong> in wall and base cabinets<br />

Installing cable connector<br />

1<br />

Insert cable <strong>for</strong> distribution into open slot<br />

3<br />

Tighten screw<br />

2<br />

Insert cable <strong>for</strong> power into open slot<br />

4<br />

Slide cable end protector over<br />

exposed cable<br />

2<br />

4<br />

3<br />

1<br />

NOTE: Ensure piercing pins are not damaged<br />

Dimensions in millimeters (inch equivalents as noted)<br />

17