SERVO-DRIVE for AVENTOS HK
SERVO-DRIVE for AVENTOS HK
SERVO-DRIVE for AVENTOS HK
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>SERVO</strong>-<strong>DRIVE</strong> <strong>for</strong> <strong>AVENTOS</strong> <strong>HK</strong><br />
C<br />
A<br />
B<br />
B<br />
B<br />
B<br />
<strong>SERVO</strong>-<strong>DRIVE</strong> set<br />
Cover set<br />
A<br />
Set includes:<br />
■ Drive unit<br />
■ 60" universal cable<br />
■ Cable connector<br />
■ Cable end protector (qty 2)<br />
B<br />
Set includes:<br />
■ <strong>SERVO</strong>-<strong>DRIVE</strong> cover plate (left)<br />
■ Cover plate (right)<br />
■ Non-handed cover cap (qty 2)<br />
■ <strong>SERVO</strong>-<strong>DRIVE</strong> switches (qty 2)<br />
■ Ø5 mm Blum distance bumper (qty 4)<br />
■ Color: gray<br />
Part no.<br />
Part no.<br />
<strong>SERVO</strong>-<strong>DRIVE</strong> set<br />
21KA000<br />
Cover set<br />
21K8000.NA<br />
Subject to technical modifications without notice. © 2011<br />
14
Power supply set<br />
C<br />
Set includes:<br />
■ Power supply<br />
■ Wall mount bracket<br />
■ Three-prong power cord<br />
■ Cable connector<br />
■ Cable end protector (qty 3)<br />
■ Cable clips (qty 10)<br />
■ 19' universal cable<br />
■ Technical in<strong>for</strong>mation<br />
Power supply set<br />
Part no.<br />
Z10NE02UG10<br />
15
Electrical components<br />
<strong>SERVO</strong>-<strong>DRIVE</strong> power supply<br />
Components<br />
Supplies power to the drive units<br />
■ UL certified<br />
■ Can power up to 18 drive units<br />
■ Connect to switched GFCI outlet<br />
■ Cable length six feet<br />
NOTE: Three-prong power cord required<br />
Specifications<br />
Input specifications<br />
Input voltage<br />
Input frequency<br />
Input current<br />
Inrush current<br />
Protection class<br />
Earth leakage current<br />
Power factor<br />
100-240 VAC<br />
50-60 Hz<br />
2.00 A<br />
100 A maximum at 230 VAC<br />
Class I<br />
1.5 mA maximum<br />
compliant with EN61000-3-2<br />
General specifications<br />
Efficiency 85% typical<br />
Isolation 3000 VAC input to output, 2000 VAC input<br />
to groud — negative output is connected<br />
to ground<br />
Switching frequency<br />
60 kHz ± 10 kHz<br />
Output specifications<br />
Output voltage 24 VDC<br />
Output power max. 100 W<br />
Minimum load none<br />
Load regulation 2%<br />
Ripple and noise 1% peak-to-peak maximum measured with<br />
additional external capacitors at output:<br />
0.1 µF and 10 µF (electrolytic capacitor)<br />
Over voltage protection<br />
Overload protection<br />
Short circuit protection<br />
at 33 VDC<br />
120-150% hiccup trip and restart mode with<br />
auto recovery<br />
continuous<br />
Environmental in<strong>for</strong>mation<br />
Operating temprature 32 °F to 149 °F<br />
Storage temperature -4 °F to 185° F<br />
Protection IP40<br />
Space requirements and safety distance <strong>for</strong> power supply<br />
A safety distance of 30 mm must be maintained <strong>for</strong> air circulation.<br />
Subject to technical modifications without notice. © 2011<br />
16
Wiring options<br />
Wiring options<br />
For wall cabinets<br />
For <strong>SERVO</strong>-<strong>DRIVE</strong> in wall and base cabinets<br />
Installing cable connector<br />
1<br />
Insert cable <strong>for</strong> distribution into open slot<br />
3<br />
Tighten screw<br />
2<br />
Insert cable <strong>for</strong> power into open slot<br />
4<br />
Slide cable end protector over<br />
exposed cable<br />
2<br />
4<br />
3<br />
1<br />
NOTE: Ensure piercing pins are not damaged<br />
Dimensions in millimeters (inch equivalents as noted)<br />
17