Causes of Scaling in FGD SystemsWet/dry Interface:• Scaling as result of a wet/dry interface iseliminated by:− Modifying the physical design of the absorber inletto eliminate the flow disturbance− Controlling the location of the wet/dry interface bymodifying the way flue gas is quenched