Vaults, professionally built.© <strong>Wertheim</strong> 03/2013<strong>Prefabricated</strong> <strong>vaults</strong>www.wertheim.at


General information<strong>Wertheim</strong> prefabricated <strong>vaults</strong> are produced in several security levels. The certificates, reffering tocountries, are acknowledged by insurance companies.QualityThe products have been tested by the laboratories VdS (Schadenverhütung GmbH) in Cologne,acknowledged all over Europe. The test was carried out following the European Standard EN1143-1 which is accepted by the European Insurance Commitee CEA (Comité Européen des Assurances).The demand for quality of all prefabricated <strong>vaults</strong> is based on many years of experience in design andproduction. The quality control system of <strong>Wertheim</strong> documents the checks of our specialists and thefinal control before delivering the products.Building and AssemblingThe vault is completed within 1 or 2 weeks, because there is no need to concrete during the installation.The prefabricated vault can be built as an independent room or in connection with an existing wall.Upon request, the inner and outer side of the vault can be covered by plaster walls, such as theelectrical and alarm installation can be prepared.ServiceThe <strong>Wertheim</strong>-service-hotline: +43 (0)1 / 604 91 66 - 300 is manned around the clock, also onsundays and holidays. <strong>Wertheim</strong> offers competent information, short reaction time and well trainedservice technicians.PricesThe fabrication of a prefabricated vault is individual, due to customer- or construction requests.For detail information and quotation please contact our team.Tel.: +43 (0)1 / 604 91 66 - 200, e-mail: office@wertheim.atGuarantee<strong>Wertheim</strong> guarantees a perfect function for the duration of 2 years (except electronic equipment).If the product should show a defect within this time, this is cleared free of charge.Supplementary documentsInstructions for use of vault doors© <strong>Wertheim</strong> 03/2013All details correspond to the current knowledge stand, however, are liability-free and are carried out under exclusion of any liability.Possible colour deviations are typographically conditional. Leaving rate and misprint and technical amendments.2


OverviewType VdS grade Sec. class Austria (with AC) Germany (with AC)ECB . S res.grade VSÖ-VVO insurance up to insurance up toEET 070 WG V EN 5 EUR Mio. 0,50 EUR Mio. 0,50FET 070 WG VI EN 6 EUR Mio. 0,75 EUR Mio. 0,75GET 100 WG VII EN 7 EUR Mio. 1,00 EUR Mio. 1,00HET 100 WG VIII EN 8 EUR Mio. 1,50 EUR Mio. 1,50HET 125 WG VIII EN 8 EUR Mio. 1,50 EUR Mio. 1,50HET 125 KB WG VIII KB EN 9 EUR Mio. 3,00 EUR Mio. 3,00IET 125 WG IX EN 9 EUR Mio. 3,00 EUR Mio. 3,00IET 165 WG IX EN 9 EUR Mio. 3,00 EUR Mio. 3,00IET 125 KB WG IX KB EN 10 EUR Mio. 4,00 EUR Mio. 4,00IET 165 KB WG IX KB EN 10 EUR Mio. 4,00 EUR Mio. 4,00JET 150 WG X EN 10 EUR Mio. 4,00 EUR Mio. 4,00JET 195 WG X EN 10 EUR Mio. 4,00 EUR Mio. 4,00JET 150 KB WG X KB EN 11 EUR Mio. 5,00 EUR Mio. 5,00JET 195 KB WG X KB EN 11 EUR Mio. 5,00 EUR Mio. 5,00KET 200 WG XI EN 11 EUR Mio. 5,00 EUR Mio. 5,00KET 250 WG XI EN 11 EUR Mio. 5,00 EUR Mio. 5,00KET 200 KB WG XI KB EN 12 EUR Mio. 7,50 EUR Mio. 7,50KET 250 KB WG XI KB EN 12 EUR Mio. 7,50 EUR Mio. 7,50LET 250 WG XII EN 12 EUR Mio. 7,50 EUR Mio. 7,50LET 250 KB WG XII KB EN 13 EUR Mio. 10,00 EUR Mio. 10,00<strong>Prefabricated</strong> <strong>vaults</strong>KB = core drill protectionAC = Alarm connectionNot specified Countries:classified accordingto the local insurance regulationwww.wertheim.at3


4Elements of prefabricated vault EET 070 with vault door EWT 085


TypesTypeEET 070FET 070GET 100HET 100HET 125HET 125 KBIET 125IET 165IET 125 KBIET 165 KBJET 150JET 195JET 150 KBJET 195 KBKET 200KET 250KET 200 KBKET 250 KBLET 250LET 250 KBVdS gradeECB . S res.gradeWG VWG VIWG VIIWG VIIIWG VIIIWG VIII KBWG IXWG IXWG IX KBWG IX KBWG XWG XWG X KBWG X KBWG XIWG XIWG XI KBWG XI KBWG XIIWG XII KBSec. classVSÖ/VVOEN 5EN 6EN 7EN 8EN 8EN 9EN 9EN 9EN 10EN 10EN 10EN 10EN 11EN 11EN 11EN 11EN 12EN 12EN 12EN 13Wall thickness(mm)7070100100125125125165125165150195150195200250200250250250Elements (mm)widthlength (max.)29002900290029002900290029002900290029002900290029002900290029002900290029002900550550550550550550550550550550600600600600600600600600600600Elementsweight (kg/m²)220225315320380390390500405510470590480600630740640750770780Fittingvault doorEWT 085FWT 085GWT 150HWT 150HWT 150HWT 150 KBIWT 150IWT 150IWT 150 KBIWT 150 KBJWT 220 KBJWT 220 KBJWT 220 KBJWT 220 KBKWT 300 KBKWT 300 KBKWT 300 KBKWT 300 KBLWT 300 KBLWT 300 KB<strong>Prefabricated</strong> <strong>vaults</strong>KB = core drill protectionTechnical description<strong>Wertheim</strong> modular <strong>vaults</strong> have been developed to equip already finalized buildings with strong roomsin standardized resistance grades according to EN 1134-1 and at the other hand to offer the possibilityto demount the strong room and reerect the modular vault at another site.All wall modules are made from a multiple bent steel sheet body, enforced with special armouring andfilled with an extremely resistant cement based cast filling. This guarantees long lasting quality andno disposal problems after the regular use.The vault is painted at the inner side, while outside the raw concrete is visible. All wall elements areprepared for locally done plaster wall cladding.<strong>Wertheim</strong> modular <strong>vaults</strong> are characterized by an optimal price/performance ratio. This means, thatthe necessary burglary resistance, which is asked by EN 1143-1, is realized by highest quality castmaterials combined with intelligent armouring systems resulting in thin wall thickness and relativelylow weight. Competitive prices prove that.Elements are built in widths from 100 mm, 150 mm, 200 mm, 250 mm, 550 mm and 600 mm. Largerwidths are possible upon special request in 5 cm steps.If the roof dimension exceeds the max. dimensions of the elements, steel girders are used to bear theload of the roof elements. The girders dimensions are dependent on the statical calculations.To each resistance grade we supply a correlative vault door.All elements are basic varnished and are painted after being welded.www.wertheim.at5


Electronically controlled safedeposit boxes in vault EET 070Completing equipmentInside panellingThe walls which are not covered from the inner equipment (e.g. deposit boxes) are decorated with aplaster plate which is screwed at a grating. Smoothing and papering are done locally by others.CeilingThe hanging plaster ceiling with the integrated illumination is mounted completely.LightingBuild in illumination.Electric installationThe electric installation is carried out of the vault ready to be connected to the mains. The installationincludes one light switch and one socket.Alarm systemThe alarm installation contains the bases for the noise detector (on site) and the necessary cablepipes.Outside panellingPlaster plates are screwed at a grating. Smoothing and papering are locally done by others.FloorThe floor is done locally by others. If there is no other wish from the customer, 5 mm layer thicknessis prepared.6


<strong>Prefabricated</strong> <strong>vaults</strong>Electronically controlled safe deposit boxes in vault EET 070Electronically controlled safe deposit boxes in vault JET 195www.wertheim.at7


Vault doors – TypesTypeVdS gradeECB . S res.gradeSec. classVSÖ/VVOInner (mm)height widthDoor thickness(mm)Weight(appr. kg)EWT 085FWT 085GWT 150HWT 150HWT 150 KBIWT 150IWT 150 KBJWT 220 KBKWT 300 KBLWT 300 KBWG VWG VIWG VIIWG VIIIWG VIII KBWG IXWG IX KBWG X KBWG XI KBWG XII KBEN 5EN 6EN 7EN 8EN 9EN 9EN 10EN 11EN 12EN 13196019601960196019601960196019601960196091091091091091091091091091091016016022522522522522528536536588090013001400141014101420200027152805Service door WG V-VIII KB EN 5-9 1100 660 160-225 430-700KB = core drill protectionVault door EWT 0858


LOCKINGSYSTEMSSTANDARDVault doors – Locking systemsSTANDARDLocking systems mechanicalDB-Lock NC-Lock EL-Lock with keypad or dialling knob1 doublebit lock2 doublebit locks with key bearerThree wheel - number combination lockFour wheel - number combination lockEWT 085--LOCKINGSYSTEMSOPTIONSFWT 085GWT 150HWT 150HWT 150 KBIWT 150IWT 150 KBJWT 220 KB--KWT 300 KBLWT 300 KB--<strong>Prefabricated</strong> <strong>vaults</strong>OPTIONALLocking systems electronicEWT 085FWT 085GWT 150HWT 150HWT 150 KBIWT 150IWT 150 KBJWT 220 KBKWT 300 KBLWT 300 KBPaxos with keypadPaxos with dialling knobPaxos second lockPaxos expansion timefunctionPaxos module basisPaxos module timefunctionPaxos module UPS-power supplyPaxos module authorisation disablingPaxos module locking unit (VdS)Paxos module switching unit (VdS)--standard lockoptionmax. 3 locks!Vault doors – standard locking systemsDoublebitlock (key with 2 bits)Adjustable high security doublebit lock with forced locking.Three wheel / Four wheel - number combination lockMechanical code lock, with three / four adjustable two-digit numbers, with 1.000.000 / 100.000.000combinations.Optional locking equipmentsForced locking sequence, upper lock to be locked before locking the lower one.Third lock with bolt work blocking, avoids unintended closing of the bolt work while the door isopen.Third lock with forced locking sequence, the third lock has to be unlocked at first and locked atlast (in connection with a forced locking sequence of the two other locks).www.wertheim.at9


Function sketchSTEPSwith keynumbercombinationlockkeypad or dialling knobwithout keyPAXOS<strong>Prefabricated</strong> <strong>vaults</strong>second lockFORvariableOPENINGdoublebit-lockdoublebit-lockonly atKWT andLWTPAXOSexpansiontimefunctionExit of event logExit of event logPAXOSmodulebasisExit of duress alarmMODULEtimefunctionMODULEpower supplyMODULEauthorisationdisablingMODULEVdS-locking unitPAXOSModuleVdS-switching unitMODULEtimefunctionMODULEauthorisationdisablingMODULEpower supplyVAULT DOORLOCK OPENwww.wertheim.at11


123456connection to the alarm system with cable run through the hingepreparation to install a door monitoring systemswitch-set for monitoring the door (optional)basement for noise detector and cable connectorcable connector (optional)Paxos module basis (optional)Vault doors – Security systemsVault doors – Security systemsSecurity systemsEWT 085FWT 085GWT 150HWT 150IWT 150HWT 150 KBIWT 150 KBJWT 220 KBKWT 300 KBLWT 300 KBPreparation for alarm connectionPreparation to install alarm detectors acc. to VdS-regulationsSwitch-set for monitoring the doorBoltwork door protectionDrill and torch protectionDiamond core drill protection (KB)-standardoptionPreparation for alarm connectionCable run through the door-frame and the upper hinge into the boltwork-room, with a leader cable forhelp.Preparation to install alarm detectors according to VdS regulationsIn the boltwork room basements for noise detectors and magnetic switches according to VdSregulations are prepared.Switch-set for monitoring the doorSet of VdS approved alarm switches and connectors, to enable a correct monitoring of the lockingstatus of the door. The installation should be done by authorized alarm companies.Boltwork door protectionAs a protection against manipulation and sabotage, the inner door cover is secured by the main locksof the vault door and by two locks.Drill and torch protectionThe boltwork is protected by special layers against attacks with mechanical and thermic tools.Diamond core drill protectionThe door is protected against attacks with crown drills.12


Vault doors – Other equipmentOther equipmentSurface primedArtistic surface designDoor bumperFortifications square for door bumper wall assemblingStainless steel entrance stepPaxos protocol printerstandardoptionEWT 085FWT 085GWT 150HWT 150IWT 150HWT 150 KBIWT 150 KBJWT 220 KBKWT 300 KBLWT 300 KBSurface primedThe door is puttied, smoothed and primed (RAL 7030 - stone grey), ready for the finish paint byothers.<strong>Prefabricated</strong> <strong>vaults</strong>Artistic surface designAn artist gives a special design according to customer wishes. Phased transitions, special shadesand marbled appearances lead to the fascinating impression.Door bumperThe door bumper protects the door from damages by striking the wall. There is the possibility toassemble on the floor or on the wall (in this case an extra mounting unit is necessary).Stainless steel entrance stepStainless steel entrance step in the wall zone below the door.Paxos protocol printerIt is a table printer with mains connection and interface cable, which is to be plugged at the modulebasis or the option expansion timefunctions. With the protocol printer the last 870 events can beprinted. These datas won’t be cancelled after printing.www.wertheim.at13


Day doorsTypesGate swing doorGlass swing doorSurfaceSteel paintedStainlessFull glassTreated surfaceLocking systemsMain lockCounter lockElectrical door openerFittingsOutside button | Inside knobOutside button | Inside buttonOther equipmentHydraulic door closerFrame------------standardoptionLocking systemsMain lockA traplock locks the door and a cylinder, which is lockable from both sides, opens the door.Counter lockThe counter lock must be unlocked before the mainlock. A cylinder, which is lockable from both sidesopens the door.Electrical door openerThe door is equipped with a holding current door openerwith feedback contact. The release to open the doorcan be done with safe-control, with key or with anotheraccess control system (e.g. fingerprint-terminal). Toopen the door with the main lock is still possible.Other equipmentHydraulic door closerWith the hydraulic closing system the door closesautomatically after each access.FrameThe door frame is necessary in case of an installationof the gate- or glass swing door at a non <strong>Wertheim</strong>vault door.Gate swing door painted with steel, with main lock,electrical door opener and hydraulic closing system.14


Delivery- and installation informationPreparation - Building siteBefore starting the assembling of the prefabricated vault thebuilding site is inspected. Thereby the way and methods how tobring in the elements will be fixed. In case of new buildings thetransport can be done per motor crane (if possible through theceiling). There are different possibilities for each situation.Necessary load hooks are defined on site. Pay attention that thefinal niveau is defined per a horizontal level.IMPORTANTThe way of transportation has to resist the weight of the elementsor the vault door.<strong>Prefabricated</strong> <strong>vaults</strong>Vault door completely fixed –boltwork, mechanical locks and mountings(electronical locks enclosed dismantled)IMPORTANTAfter installation of the Paxos Electronic Lock it is forbidden toweld at the vault door.www.wertheim.at15


<strong>Wertheim</strong> GmbH, Wienerbergstraße 21-25, A-1100 Vienna, Tel.: +43 (0)1 / 604 91 66-0, Fax: Ext. 21e-mail: office@wertheim.at, internet: www.wertheim.at