10.07.2015 Views

Extech Catalog PDF

Extech Catalog PDF

Extech Catalog PDF

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Extech</strong> 400 Series Professional MultiMeters headerEX400Series<strong>Extech</strong> 400 Series Professional MultiMetersFeaturing models with built-in non-contact InfraRed ThermometerCommon Features:• Large backlit LCD display witheasy-to-read 1" digits• Type K thermometer built-infor temperature measurements• Low current capability:measure down to 0.1µA• Input fuse protection andmis-connection warnings• Dimensions: 7.4x3.2x2"(187x81x50mm) Weight:0.75lbs (342g)• Complete with CAT III testleads, multi-position tilt standand velcro strap for hanging,protective holster with test leadholder, bead wire temperatureprobe (-4 to 482°F/-20 to250°C), and 9V batteryModel EX410/EX411• True RMS (EX411)• Manual RangingModel EX420/EX430• True RMS (EX430)• Autoranging• Capacitance• FrequencyModel EX450• Built-in IR Thermometer• AutorangingModel EX470• Built-in IR Thermometer• True RMS• Autoranging• Capacitance• Frequency• Relative functionPatentedEX400S E R I E SFunctions EX410 EX411 EX420 EX430 EX450 EX470Averaging/True RMS Averaging True RMS Averaging True RMS Averaging True RMSBasic Accuracy (VDC) ±0.5% ±0.3% ±0.3% ±0.3% ±0.5% ±0.3%AC Voltage 1mV to 750V 1mV to 750V 0.1mV to 750V 0.1mV to 750V 1mV to 750V 0.1mV to 750VDC Voltage 0.1mV to 1000V 0.1mV to 1000V 0.1mV to 1000V 0.1mV to 1000V 0.1mV to 1000V 0.1mV to 1000VAC Current 0.1mA to 20A 0.1mA to 20A 0.1µA to 20A 0.1µA to 20A 0.1µA to 20A 0.1µA to 20ADC Current 0.1µA to 20A 0.1µA to 20A 0.1µA to 20A 0.1µA to 20A 0.1µA to 20A 0.1µA to 20AResistance 0.1Ω to 20MΩ 0.1Ω to 20MΩ 0.1Ω to 40MΩ 0.1Ω to 40MΩ 0.1Ω to 20MΩ 0.1Ω to 40MΩCapacitance — — 0.01nF to 100µF 0.01nF to 100µF — 0.01nF to 100µFFrequency — — 0.001Hz to 10MHz 0.001Hz to 10MHz — 0.001Hz to 10MHzTemperature (IR) — — — — -58 to 518°F -58 to 518°F(-50 to 270°C) (-50 to 270°C)Temperature (Type K) -4 to 1382°F -4 to 1382°F -4 to 1382°F -4 to 1382°F — -4 to 1382°F(-20 to 750°C) (-20 to 750°C) (-20 to 750°C) (-20 to 750°C) (-20 to 750°C)Duty Cycle — — 0.1% to 99.9% 0.1% to 99.9% — 0.1% to 99.9%Continuity / Diode Yes Yes Yes Yes Yes YesCategory Rating CAT III-600V CAT III-600V CAT III-600V CAT III-600V CAT III-600V CAT III-600VCAT II-1000V CAT II-1000V CAT II-1000V CAT II-1000V CAT II-1000V CAT II-1000VWarranty 1 year 1 year 1 year 3 years 3 years 3 yearsNIST Certified MetersOur in-house calibration lab certifies <strong>Extech</strong> products to NIST standards. Meters with NISTcertificates come complete with data. Our laboratory conforms to MIL STD 45662, ISO17025, Guide 25, and ANSI/NCSL Z540-1-1994.EX410-NIST .................EX410 MultiMeter with NIST CertificationEX411-NIST .................EX411 MultiMeter with NIST CertificationEX420-NIST .................EX420 MultiMeter with NIST CertificationEX430-NIST .................EX430 MultiMeter with NIST CertificationEX450-NISTL* .............EX450 MultiMeter with NIST CertificationEX470-NISTL* .............EX470 MultiMeter with NIST CertificationAccessories (see pg. 42-43)CA500 ...........................Case with shoulder strap and side pocketsTP873............................Replacement Bead wire Temperature ProbeHG500 ..........................Magnetic Hanging Strap* Product certified to all functions except IR ThermometerCA500: Durable casewith compartments formeter and test leads<strong>Extech</strong> Instruments: The brand of choice …trusted by the professionals. 27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!