<strong>DOORS</strong>f. Doors, except cab-end, body end doors, will be powered by either a pneumatic or electricoperator. There shall be a three position switch located adjacent to the door that allows thedoor to work in either automatic mode, manual mode, or locks the door in the closedposition. The switch can only be activated by use <strong>of</strong> a VRE coach key. There shall be twomethods to activate the door mechanism, one is a push plate located at a convenient heightadjacent to the door and the other is a kick plate located at the base <strong>of</strong> the door. The doortiming shall be adjustable from 15 seconds to 30 seconds and include obstruction detection.8.5 Electrical Locker Doorsa. All electrical locker doors shall be accessible by a standard coach car key.8.6 Door Control8.6.1 Generala. The side entrance doors on the cars shall be arranged to operate from local Master DoorControllers (MDC) located one on each side <strong>of</strong> the car. If there are two side entrance doorson each side <strong>of</strong> the train, the MDCs shall be located diagonally across from each other.1) These controllers shall use the low voltage AC train line signals to control either electric orpneumatic door operators.2) Each door shall also have venting air valves for manual use and/or emergency override.3) Operation <strong>of</strong> the side entrance doors must be completely compatible with those on otherVRE cars.b. Design <strong>of</strong> the side door control system shall meet the requirements <strong>of</strong> 49CFR238 and the -recommendations <strong>of</strong> APTA RP-C&S-012-02 and APTA SS-M-18-<strong>10</strong> (latest versions).c. All cars shall be tested for multiple unit operation <strong>of</strong> door control prior to shipment.d. The final design <strong>of</strong> the side entrance door control, door operator, and door indication systemsshall be submitted to VRE for review and acceptance, before the equipment is installed on thefirst car. [CDRL 8-04] Complete details <strong>of</strong> the design, showing compliance with allrequirements <strong>of</strong> this Section and other relevant sections <strong>of</strong> the contract, shall be provided. Thedesign review shall include drawings and schematics, and also a written technical description <strong>of</strong>operation <strong>of</strong> the circuit. The description shall include sufficient information as to allow thereader to understand operation <strong>of</strong> all push-buttons, lights and annunciation signals. The designshall be submitted within 120 days <strong>of</strong> Notice to Proceed (NTP).8.6.2 Operationa. The side entrance doors shall be arranged for remote electric control and pneumatic or electricoperation.b. The side entrance door control system shall be train lined to permit operation <strong>of</strong> all sideentrance doors on one side <strong>of</strong> the train from any vestibule Master Door Controller panel onthe same side <strong>of</strong> the train.c. Side entrance Master Door Controller (MDC) panels shall be provided on each side <strong>of</strong> thetrain so that an attendant can operate the buttons to open and close the doors while standing inRFP No. 012-001 – New Passenger Rail Cars III<strong>Page</strong> 4 <strong>of</strong> <strong>10</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!