C TDescription<strong>Test</strong> <strong>Kit</strong> Equipment234<strong>5T</strong>he Pro Strips 5 biothreat screening device isa simple-to-use Hand-Held Assay (HHA) forrapid, qualitative detection of Anthrax, Ricintoxin, Botulinum toxin, Y. pestis and SEB.A confirmatory evaluation is recommended.Important InformationPlease review complete instructions prior touse. Use only the materials supplied in this kit.Always use proper PPE or refer to yourorganizations’s written protocol.Humidity levels above 80% can slow results.Do not use in direct rain.Device works best in temperatures between38 and 90 degrees fahrenheit or 4 to 32degrees celsius.Maximum temperature range:34.to 120 degrees fahrenheit1 to 49 degrees celsius.Dropper/SwabDiluent tubeA N T H R A XR I C I N T O X I NB O T U L I N U MY. P E S T I SS E BPouched<strong>Test</strong> Device1Tear open the inner white pouch to removethe test device. Place the device and thediluent tube onto a flat, horizontal surface infront of you.Collection of a liquid sample12A N T H R A XR I C I N T O X I NB O T U L I N U MY. P E S T I SS E BC TThe test device should be placed in frontof you with the text to your left and thesample well to the right as shown above.Unscrew the cap from the diluent tube.While removing the swab, rub the foam tipagainst the inside walls to extract excessliquid then remove the swab completely.34Mr.SmithP.O. Box 812Anytown Ca 92804Swab the suspect material orcontaminated area carefully. Collect asmuch material as possible by swirling theswab tip slowly.Return the swab and collected sample back tothe diluent tube. Tighten the cap and gentlyshake the tube for approximately 5 seconds.Move to step 6.5DO NOT open the inner white pouch until youare ready to perform the evaluation.Contact UsAdvnt <strong>Biotechnologies</strong> LLC. USA888-223-3269Emergency information 24/7602-803-153<strong>5T</strong>echnical info can also be found atwww.advnt.orgChain ofCustodylabelFoldedinstructioninsertPro Strips and the Pro Strips logo are registered trademarks of Advnt <strong>Biotechnologies</strong> 2009 Rev. 2 11/08Tear open the inner white pouch to removethe test device. Place the device and thediluent tube onto a flat, horizontal surfacein front of you.A N T H R A XR I C I N T O X I NB O T U L I N U MY. P E S T I SS E BC TThe test device should be placed in frontof you with the text to your left and thesample well to the right as shown above.Unscrew the cap from the diluent tube.While removing the swab, rub the foam tipagainst the inside walls to extract excessliquid then remove the swab completely.Place the absorbent end of the swab intothe suspect liquid and swirl for 5 seconds.Return the swab and collected sample back tothe diluent tube. Tighten the cap and gentlyshake the tube for approximately 5 seconds.Move to step 6.


6 7 8 9 10 11C TA N T H R A XR I C I N T O X I NB O T U L I N U MY. P E S T I SS E B<strong>Instruction</strong> <strong>Sheet</strong><strong>Test</strong> ResultsSTRONGPOSITIVEWEAKPOSITIVE<strong>PS</strong>-<strong>5T</strong>CTA N T H R A XR I C I N T O X I NCTA N T H R A XR I C I N T O X I NB O T U L I N U MNEGATIVEB O T U L I N U MY. P E S T I SS E BY. P E S T I SS E BINVALIDINVALIDRemove the clear cap from the tip of thediluent tube. Break off the tip anddiscard. The tube now becomes adropper for dispensing the sample ontothe test deviceInvert the tube to a 45 degree angle andVERY SLOWLY add 10 to 11 drops to thesample well. DO NOT add more than 11drops. (11 drops = 0.55 - 0.60ml) Returnthe clear cap back to the dropper and setit to the side.Set a timer and allow a maximum of 15minutes before interpreting the results.You may see results in as little as 3minutes. DO NOT interpret results after 30minutesAs the test begins to work, a reddishcolor will move across the five (5) resultwindows. Lines should always appear atthe control line (C) This is an indicationthat the test is working correctly.The windows above represent potentialresults. A weak positive, regardless of itsintensity, should be considerd positive.Invalids are rare but occur when tests areout-dated or exposed to extreme weatherand should be re-run.With your results collected, return allitems back to the original zip-lock foilpouch. Zip the pouch closed, completethe chain of custody label, remove theadhesive backing and attach it over thepouch. Pouch is now ready for the lab.5Anthrax Ricin BotulinumY. pestis SEB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!