10.07.2015 Views

Haskris Brochure (revised December-02) - Chiller City

Haskris Brochure (revised December-02) - Chiller City

Haskris Brochure (revised December-02) - Chiller City

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Model R400click for home pageRefrigerated Water Recirculating Systems100 Kelly Street, Elk Grove Village, IL 60007Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.comCooling Capacity( at 65°F supply water temp. )Compressor HPwith air cooled condenserWattsBtu/Hr412,50042,625with water cooled condenserWattsBtu/Hr413,50046,<strong>02</strong>5RefrigerantWater Pump Capacityseveral alternativesavailableR227.9 GPM (30.0 LPM)Pump Motor HP 3/4R227.9 GPM (30.0 LPM)3/4Reservoir VolumePower Requirements*Dimensionsseveral alternativesavailable30 Gallons (114 Liters)208/230V-3-60Hz30 Gallons (114 Liters)208/230V-3( W x D x H ) in. 47 x 36 x 56 30 x 36 x 48-60HzShipping Weight900 Lbs. (408 Kgs.) 600 Lbs. (272 Kgs.)• Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity.• Unit specifications will change by adding certain options.* Also available in 50HzAvailable OptionsCustom DesignNon - Refrigerated Modelsc l i c kc l i c kc l i c kSimilar Models (Click)R033R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000


click for home pageOptional Design FeaturesApplies to all <strong>Haskris</strong> modelsBasic Design Options:Option (C): Water-cooled condenser with water saver control valve.For refrigerated units only.Option (D):Option (R):Two separate water pumping systems.Alternate Water PumpOption (Y): Multiple water circuits with flowmeters and meteringvalves, when cooling more than one piece of equipmentfrom a single pump.Option (O): Hand shut-off valves. Recommended with Option (Y).Option (I):Option (J):For refrigerated units with air cooled condensers, whenambient air temperatures are excessively high.For refrigerated units with air cooled condensers, whenambient air temperatures are excessively low.To Protect Your Equipment:Option (B): High temperature thermostat to de-energize pumpmotor on a rise in water temperature.Alternately, can be interlocked with your equipment.Option (N): Alarm system for high water temperature. Choice of“buzzer” only (single stage), or “buzzer” and pumpcutout in sequence (two stage).Option (S): Flow switch to provide protection if water flow fails forany reason.Option (L): Supply water filter.To Refine or Enhance Performance:Option (G): Manual refrigerant hot gas bypass system for improvedwater temperature stability.For refrigerated units cooling a steady heat load. See option(H).Option (H): Electronically controlled refrigerant hot gas bypasssystem for improved water temperature stability, to+/- 0.1 C or better.For refrigerated units cooling a variable heat load. Alsorecommended for refrigerated units with air cooled condensers,when ambient air temperatures are variable and watertemperature stability is critical.Option (H): Electronic close control for improved watertemperature stability.For non-refrigerated, water-to-water (WW) units only.Convenience Options:Option (A): Flowmeter, to visually display flow of water throughequipment.Option (M): Time clock, to operate the unit after normal workinghours, up to 60 minutes.Option (P): Locking casters (in lieu of standard levelling legs).Miscellaneous Options:Option (K): Used to designate any “non-standard” feature youwould like built into your unit.Click on the Custom Design button belowRefrigerated Modelsc l i c kNon - Refrigerated Modelsc l i c kCustom Designc l i c k100 Kelly Street, Elk Grove Village, IL 60007, Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!