10.07.2015 Views

GT tanks

GT tanks

GT tanks

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3<strong>GT</strong> <strong>tanks</strong>Heating3. HeatingApplicationsThe <strong>GT</strong>-HR <strong>tanks</strong> are conventional diaphragm-typeexpansion <strong>tanks</strong> ranging from 8 to 1000 litres for 6 barworking pressure for closed heating systems andchilled-water applications. These <strong>tanks</strong> can beincorporated in an expansion system in a tinyhousehold or a large multi-storey building.Typical applications:• domestic-heating and chilled-water systems• commercial-building heating and chilled-watersystems• industrial-heating and chilled-water systems.<strong>GT</strong>-HR <strong>tanks</strong> can be used with any Grundfos pump.Tank rangeThe <strong>GT</strong>-HR <strong>tanks</strong> are available in sizes ranging from8 to 1000 litres and are suitable for vertical installation.The <strong>tanks</strong> have a non-replaceable diaphragm that ispre-charged with nitrogen (1.5 bar).The <strong>tanks</strong> have a non-toxic butyl rubber diaphragm,dividing the tank chamber into two compartments.The upper compartment contains compressednitrogen. The lower compartment has a liner ofpolypropylene (PP) and is filled with water from thepump.SizingThe required tank volume can be calculated from theformula below:V e =(0.07 x t - 2.5) x (p s + 1)100 x (p s - p e )x V [litres]If the necessary information required to calculate thetank according to the formula is not available, the sizingof the tank can be based on heat input to the installationand maximum system pressure.Pre-conditionsHeating systems: flat radiators, specific water volumeof 11.3 l/kW, flow-pipe temperature of 70 °C and returnpipetemperature of 50 °C.Maximum systempressure [bar]6Pre-charge pressure [bar] 3 Tank size [l]Heat input [kW]4 88 1216 1827 2544 3560 50100 80120 100170 140250 200310 250370 300490 400620 500740 600990 8001230 1000Grundfos recommendation• Set the tank pre-charge pressure to at least 0.2 barabove the static pressure of the heating system.• The tank pre-charge pressure should not be lowerthan 1 bar.V etp sp eVTank volume [litres]Maximum temperature in system [°C]Maximum system pressure [bar] (safety valve pressure)Pre-charge pressure [bar]Total volume of water in system [litres]Sizing exampleA heating system has a heat input of 160 kW, themaximum system pressure is 6 bar, and the heatingsystem will be pre-charged by 3 bar.Use the column for 6 bar maximum system pressure.The nearest value above 160 kW is 170 kW.This corresponds to a tank size of 140 litres.16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!