GmbHSpecification <strong>MicroCen</strong> ® <strong>16</strong> <strong>MicroCen</strong> ® <strong>16</strong>Catalog No. (50/60 Hz, 1 phase) 21 <strong>16</strong> 000Laborgeräte<strong>MicroCen</strong> ®<strong>16</strong>VoltageMaximum Capacity220 – 240 V24 x 2.2 mlMaximum Speed (rpm) 14,800Max. g-Force (depending on rotor) in x g <strong>16</strong>,<strong>16</strong>3Minimum Speed (rpm) 200Information DisplayPreset TimeDrive SystemAcceleration and DecelerationLarge LCD display10 sec. up to 99 min. 59 sec., short run and continuous run possibleMaintenance-free brushless induction drive motorShort acceleration and deceleration times, Softstart/Softstop possibleShortest acceleration time 13 sec. (rotor 21 <strong>16</strong> 300) / 14 sec. (rotor 21 <strong>16</strong> 200)Shortest deceleration time 11 sec. (rotor 21 <strong>16</strong> 300) / 12 sec. (rotor 21 <strong>16</strong> 200)Lid LockTemperature increase during runMax. kinetic energy1,721 NmPower consumption95 WNoise level at max. speed< 60 dBInterference suppression EN 61326Dimensions (W x D x H): in cm(in inches)Shipping dimensions in cm(in inches)Automatic motorized lid opening, emergency opening of lidMax. 9°/13°C (rotor 21 <strong>16</strong> 300) / Max. 10°C/11.1°C (rotor 21 <strong>16</strong> 200)After 20 min. continuous run21.2 x 26.6 x 17.6(8.3 x 10.5 x 6.9)31.0 x 33.0 x 38.0(12.2 x 13.0 x 15.0)Net weight in kg (lbs.) 6.2 (13.7)Gross Weight in kg (lbs.) 7.6 (<strong>16</strong>.8)SMALL MICROLITER CENTRIFUGEAll products built by Herolab carry the CE sign. Herolab has its own Quality Management System which is conform to ISO 9001.Herolab GmbH LaborgeräteLudwig-Wagner-Str. 1269<strong>16</strong>8 WieslochGERMANYpage 3 of 522001100- -0011


GmbHLaborgeräte<strong>MicroCen</strong> ®<strong>16</strong>Fixed Angle Rotors:Cat. No.MaterialImageMax. CapacityMax. SpeedMax. g-forceIncludedExtrasAccessories(Tubes/Adapters)21 <strong>16</strong> 300Polypropylene12 x 1.5/2.2 ml14,800 rpm15,183 x gPolysulfone lid(21 <strong>16</strong> 900)see page 521 <strong>16</strong> 32021 <strong>16</strong> 25021 <strong>16</strong> 26021 <strong>16</strong> 20021 <strong>16</strong> 220AluminumPolypropyleneAluminumPolypropyleneAluminumPlease note that the rotors made ofpolypropylene can be autoclaved only approx.20 times for 10-15 min. at 121°C.Aluminum rotors areautoclavable any number of times.Microhematocrit Rotor:12 x 1.5/2.2 ml18 x 1.5/2.2 mlresp.18 x 0.25/0.4 ml(2 rows)18 x 1.5/2.2 mlresp.18 x 0.25/0.4 ml(2 rows)24 x 1.5/2.2 ml24 x 1.5/2.2 ml14,800 rpm15,183 x g14,800 rpm14,448 x gresp.15,673 x g14,800 rpm14,448 x gresp.15,673 x g14,800 rpm<strong>16</strong>,<strong>16</strong>3 x g14,800 rpm<strong>16</strong>,<strong>16</strong>3 x gPolysulfone lid(21 <strong>16</strong> 900)Polysulfone lid(21 <strong>16</strong> 900)Polysulfone lid(21 <strong>16</strong> 900)Polysulfone lid(21 <strong>16</strong> 900)Polysulfone lid(21 <strong>16</strong> 900)see page 5see page 5see page 5see page 5see page 5SMALL MICROLITER CENTRIFUGECat. No. Image Max. CapacityMax. SpeedMax. g-forceIncluded ExtrasAccessories21 <strong>16</strong> 40024 capillaries 35 µl(Ø 1.4 x 50 mm)13,000 rpm11,903 x gReader card (21 <strong>16</strong> 925)Rotor lidseepage 5All products built by Herolab carry the CE sign. Herolab has its own Quality Management System which is conform to ISO 9001.Herolab GmbH LaborgeräteLudwig-Wagner-Str. 1269<strong>16</strong>8 WieslochGERMANYpage 4 of 522001100- -0011


GmbHLaborgeräteAvailable Herolab Tubes and Adapters for <strong>MicroCen</strong> ® <strong>16</strong> Rotors:Accessories for Fixed Angle Rotors:Cat. No. Reaction Vials Suitable for rotor:21 <strong>16</strong> 804 0.4 ml21 <strong>16</strong> 250 and 21 <strong>16</strong> 260 (directly)all fixed angle rotors (with adapter 21 <strong>16</strong> 212)Piecesper pack21 <strong>16</strong> 805 0.5 ml all fixed angle rotors (with adapter 21 <strong>16</strong> 211) 10021 <strong>16</strong> 815 1.5 ml all fixed angle rotors (directly) 10021 <strong>16</strong> 822 2.2 ml all fixed angle rotors (directly) 100Cat. No.Adapters / Spare Lid100Piecesper pack21 <strong>16</strong> 211 Adapter for reaction vials 0.5/0.7 ml, Ø 7.9/10 x 28/31 mm (Cat. No 21 <strong>16</strong> 805) 621 <strong>16</strong> 212 Adapter for reaction vials 0.25/0.4 ml (Cat. No. 21 <strong>16</strong> 804) 621 <strong>16</strong> 213 Adapter for PCR ® tubes 0.2 ml 621 <strong>16</strong> 900 Spare Lid (Polysulfone) for all fixed angle rotors 1Accessories for Microhematocrit Rotor:Cat. No. Tubes SizePiecesper pack21 <strong>16</strong> 930 35 µl Microhematocrit capillary tubes, heparinized Ø 1.4 x 50 mm 200Cat. No.AccessoriesPiecesper pack21 <strong>16</strong> 920 Reading disk 121 <strong>16</strong> 925 Capillary reader card 121 <strong>16</strong> 935 Capillary tubes sealing putty (6 plates) 121 <strong>16</strong> 940 Rubber ring 1For detailed information about the comprehensive range of tubes and bottles fromour production as well as their possible use in centrifuges of other manufacturersplease refer to our catalog “<strong>Centrifuge</strong> Labware”.The consuma bles a lso inc lude the most common tub es and b ottles for ultracentrifuges.ISO 9001.page 5 of 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!