10.07.2015 Views

test certificate EN 1021-1,2 - Vescom

test certificate EN 1021-1,2 - Vescom

test certificate EN 1021-1,2 - Vescom

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Vescom</strong> bvDhr. Ron VerlouwPostbus 705753 AV DEURN<strong>EN</strong>ederlandYour notice of Your reference Date07-03-2013 14-03-2013Analysis Report 13.01149.01Required <strong>test</strong>s :<strong>EN</strong> <strong>1021</strong>-1 (2006)<strong>EN</strong> <strong>1021</strong>-2 (2006)Furniture - Assessment of the ignitability of upholsteredfurniture - Ignition source : smouldering cigaretteFurniture - Assessment of the ignitability of upholsteredfurniture – Ignition source : match flame equivalentIdentificationnumberT1303680Information given by the clientLindau : 80 % wool – 20 % nylon . 536 gr/mtrDate of receipt07-03-2013Pros Van HoeylandOrder responsibleThis report runs to 3 pages and may be reproduced, as long as it is presented in its entire form, without written permission ofCentexbel.The results of the analysis cover the received samples. Centexbel is not responsible for the representativeness of the samples.In assessing compliance with the specifications, we did not take into account the uncertainty on the <strong>test</strong> results.VAT BE 0459.218.289C<strong>EN</strong>TEXBEL-G<strong>EN</strong>TTechnologiepark 7BE-9052 ZwijnaardeTel. + 32 9 220 41 51 • Fax + 32 9 220 49 55gent@centexbel.beFin. Acc. 210-0472965-45IBAN BE44 2100 4729 6545C<strong>EN</strong>TEXBEL-VERVIERSAvenue du Parc 38BE-4650 Herve (Chaineux)Tel. + 32 87 32 24 30 Fax + 32 87 34 05 18chaineux@centexbel.be


Analysis Report 13.01149.01Date 14-03-2013Page 2/3Reference:T1303680 - Lindau : 80 % wool – 20 % nylon . 536 gr/mtrFurniture - Assessment of the ignitability of upholstered furniture - Ignition source :smouldering cigaretteDate of ending the <strong>test</strong>Standard usedDeviation from the standardConditioning13-03-2013<strong>EN</strong> <strong>1021</strong>-1 (2006)-23°C, relative humidity 50%The following <strong>test</strong> results relate only to the ignitability of the combination of materials underthe particular conditions of <strong>test</strong> ; they are not intended as a means of assessing the fullpotential fire hazard of the materials in use.Water soaking of the cover NoFillingT 23140 (Recticel) - non-fire retardant foam - ± 22 kg/m³Smouldering criteriaUnsafe escalating combustionTest assembly consumedSmoulders to extremitiesSmoulders through thicknessSmoulders more than 1 hourFinal examination / active smoulderingFlaming criteriaOccurence of flames1nonononononono2nonononononononon-ignitionnon-ignitionConclusionNon-ignitionPerformed under accreditation in the fire lab under the responsibility of Pros Van Hoeyland

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!