<strong>Vescom</strong> bvDhr. Ron VerlouwPostbus 705753 AV DEURN<strong>EN</strong>ederlandYour notice of Your reference Date24-04-2013 03-05-2013Analysis Report 13.01972.02Required <strong>test</strong>s :<strong>EN</strong> <strong>13773</strong> (2003)IdentificationnumberT1306354Information given by the clientBedra 8019.02Date of receipt24-04-2013Pros Van HoeylandOrder responsibleThis report runs to 4 pages and may be reproduced, as long as it is presented in its entire form, without written permission ofCentexbel.The results of the analysis cover the received samples. Centexbel is not responsible for the representativeness of the samples.In assessing compliance with the specifications, we did not take into account the uncertainty on the <strong>test</strong> results.VAT BE 0459.218.289C<strong>EN</strong>TEXBEL-G<strong>EN</strong>TTechnologiepark 7BE-9052 ZwijnaardeTel. + 32 9 220 41 51 • Fax + 32 9 220 49 55gent@centexbel.beFin. Acc. 210-0472965-45IBAN BE44 2100 4729 6545C<strong>EN</strong>TEXBEL-VERVIERSAvenue du Parc 38BE-4650 Herve (Chaineux)Tel. + 32 87 32 24 30 Fax + 32 87 34 05 18chaineux@centexbel.be


Analysis Report 13.01972.02Date 03-05-2013Page 2/4Reference:T1306354 - Bedra 8019.02Textiles – Burning behaviour – Curtains and drapes - Textile fabrics - Determination ofthe ignitability of vertically oriented specimens.Date of ending the <strong>test</strong>Standard usedProduct standardDeviation from the standardConditioningIgnition30-04-2013<strong>EN</strong> 1101 (1995) + A1 (2005)<strong>EN</strong> <strong>13773</strong> (2003)-20°C, relative humidity 65%Bottom edgeThe <strong>test</strong> specimens have not been cleaned nor submitted to an accelerated ageing procedure.LengthFlame applicationtime (s)12345101520Cases ofignition00000000Cases ofnon-ignition11111115The mean of the recorded times at which ignition was observed is calculatedNo ignition within 20 s


Analysis Report 13.01972.02Date 03-05-2013Page 3/4WidthFlame applicationtime (s)12345101520Cases ofignition00000000Cases ofnon-ignition11111115The mean of the recorded times at which ignition was observed is calculatedNo ignition within 20 sPerformed under accreditation in the fire lab under the responsibility of Pros Van Hoeyland


Analysis Report 13.01972.02Date 03-05-2013Page 4/4Reference:T1306354 - Bedra 8019.02Textiles and textile products – Burning behaviour – Curtains and drapes. Measurement offlame spread of vertically oriented specimens with large ignition source.Date of ending the <strong>test</strong>Standard usedProduct standardDeviation from the standardConditioning03-05-2013<strong>EN</strong> 13772 (2011)<strong>EN</strong> <strong>13773</strong> (2003)-20°C, relative humidity 65%The <strong>test</strong> specimens have not been cleaned nor submitted to an accelerated ageing procedure.LengthSeverance 220 mm threadSeverance 370 mm threadSeverance 520 mm threadTime to sever 520 mm thread (s)Destroyed length (mm)Flaming debrisFace Anonono/140noFace Bnonono/125noFace Anonono/130noFace Anonono/130noWidthSeverance 220 mm threadSeverance 370 mm threadSeverance 520 mm threadTime to sever 520 mm thread (s)Destroyed length (mm)Flaming debrisFace Anonono/130noFace Bnonono/130noFace Anonono/125noFace Anonono/130noClassification in accordance with <strong>EN</strong> <strong>13773</strong>Class 1Performed under accreditation in the fire lab under the responsibility of Pros Van Hoeyland