NEWfor T-2/HT-2Advantages add up with<strong>Reveal</strong> <strong>Q+</strong>Quantifiably Better.Neogen introduces <strong>Reveal</strong> <strong>Q+</strong> for T-2/HT-2, an easy-to-use,rapid, quantitative lateral flow test that provides unparalleledaccuracy in only 6minutes. <strong>Reveal</strong> <strong>Q+</strong>for T-2/HT-2 is theproduct of Neogen’sinnovative technologywhich yields accurateand reproduciblequantitative results.+ Unmatched accuracy andreproducibility+ Quantitative results, 50–600 ppb+ Minimal training required+ The best technical and R&D supportin the industry+ Simple waterextraction+ Fast time to result+ Easy-to-useTo place an order, or for more information, contact your local Neogen Europerepresentative, or visit our web site at www.neogeneurope.comNeogen Europe Ltd. • The Dairy School • Auchincruive, Ayr, Scotland • KA6 5HWTel: +44 (0)1292 525610 Fax: +44 (0)1292 525602 • info_uk@neogeneurope.com©Neogen Corporation, 2012. AccuScan, Neogen and <strong>Reveal</strong> are registered trademarks of Neogen Corporation, Lansing, Mich.NE1689-1112


<strong>Reveal</strong> ® <strong>Q+</strong> for T-2/HT-2<strong>Procedure</strong>Note: Please read kit instructions completely before performing test.1. Prepare by entering the QR codeinto the AccuScan ® Pro Reader.2. Obtain a representative sample.Grind and weigh out a 10 g sample.3. Add 100 mL of distilled water tosample.4. Shake vigorously for 3 minutes, orblend for 1 minute.5. Settle, then filter. 6. Add 500 µL of sample diluent to red 7. Add 100 µL sample extract to reddilution cup.dilution cup and mix up and down 5times.8. Transfer 100 µL to sample cup.9. Place a new <strong>Reveal</strong> <strong>Q+</strong> T-2/HT-2strip into the sample cup. Set atimer for 6 minutes.10. Remove promptly at 6 minutesand interpret results using theAccuScan Pro Reader.Results shown on the AccuScan ProReader.#8285 <strong>Reveal</strong> <strong>Q+</strong> for T-2/HT-2Threshold: 50–600 ppbTesting time: 6 minutesMaterials Provided25 test strips25 sample cups25 red dilution cups2 bottles of sample diluentKit instructionsMaterials Available from NeogenGrinder (#9401, 9453)Scale (#9427)Sample collection cups w/ lids (#9428)Filter syringe (#9420)<strong>Reveal</strong> sample cup rack (#9475)AccuScan Pro Reader (#9565)Sample collection tubes with caps (#9421)Timer (#9426)Dispensing pump or graduated cylinder (#9448,9447)Pipettor, 100 µL (#9272, 9278, 9860)Pipettor tips, 100 µL (#9407, 9410, 9417)Pipettor, 500 µL (#9336)Pipettor tips, 200–1000 µL (#9464, 9487)To place an order, or for more information, contact your local Neogen Europerepresentative, or visit our web site at www.neogeneurope.comNeogen Europe Ltd. • The Dairy School • Auchincruive, Ayr, Scotland • KA6 5HWTel: +44 (0)1292 525610 Fax: +44 (0)1292 525602 • info_uk@neogeneurope.com©Neogen Corporation, 2012. AccuScan, Neogen and <strong>Reveal</strong> are registered trademarks of Neogen Corporation, Lansing, Mich.NE1689-1112

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!