12.07.2015 Views

Food Allergen Testing Solutions - NOACK

Food Allergen Testing Solutions - NOACK

Food Allergen Testing Solutions - NOACK

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Almondß-Lactoglobulin (BLG)CaseinEggGliadin (Gluten)HazelnutLupineMustardPeanutSesameShellfish/CrustaceanSoySoy FlourTotal Milk (Casein & Whey)WalnutThe Dairy School, Auchincruive, Ayr, KA6 5HW, Scotland, UKTel: +44 (0) 1292 525 610 • Fax: +44 (0) 1292 525 602E-mail: info_uk@neogeneurope.com • Web: www.neogeneurope.comMycotoxins • <strong>Allergen</strong>s • Histamine • Microbiology • Hygiene/Sanitation


Test Formats and KitsNeogen’s food allergen tests can detect the target allergen in ingredients, liquids, clean-in-placerinses, finished foods, and on environmental surfaces.Reveal ® for <strong>Food</strong> <strong>Allergen</strong>sNeogen’s Reveal format combines the accuracy of previous generations of rapid food allergen screeningtests with the simplicity and speed of a dipstick format. After extraction, a tester needs only 5–10minutes to produce accurate and easy-to-interpret sample results. After dipping the strip into a sampleextract, two lines will form to indicate the presence of at least 5 ppm of an allergen. If an allergen isnot detected, only one control line will form to indicate the test has been performed correctly.Reveal8438 Reveal for Peanut <strong>Allergen</strong> Screens at 5 ppm 25 samples per kit8478 Reveal for Total Milk <strong>Allergen</strong> Screens at 5 ppm 24 samples per kitReveal ® 3-D for <strong>Food</strong> <strong>Allergen</strong>s (formerly RAPID 3-D tests)Neogen’s Reveal 3-D tests are uniquely designed with 3 lines of detection and can be used to screen forthe presence of low levels of allergens in environmental swabs virtually anywhere. Sample preparationand testing take less than 10 minutes, making them excellent choices for on-site food allergen control.Each kit contains everything needed (including swabs) to perform 10 single use tests.Reveal 3-D902086G Reveal 3-D Almond Screens at low ppm levels 10 tests per kit902075M Reveal 3-D Casein Screens at low ppm levels 10 tests per kit902082Q Reveal 3-D Egg Screens at low ppm levels 10 tests per kit901031P Reveal 3-D Gluten Screens at low ppm levels 10 tests per kit902087E Reveal 3-D Hazelnut Screens at low ppm levels 10 tests per kit901041L Reveal 3-D Peanut Screens at low ppm levels 10 tests per kit902081S Reveal 3-D Crustacea Screens at low ppm levels 10 tests per kit902093K Reveal 3-D Soy Screens at low ppm levels 10 tests per kitAlert ® for <strong>Food</strong> <strong>Allergen</strong>sNeogen’s Alert line of microwell food allergen tests are S-ELISAs that allow for the rapid screening of afood ingredient, food product, CIP rinse waters or environmental sample for the presence of a target foodallergen. Each test kit contains all the reagents needed to perform the test, and requires only a minimumof training and additional equipment. In 30 minutes following extraction, testers can visually determinewhether a sample contains more or less of a target food allergen than the supplied control (e.g., 5 ppm).The Alert test is ideally suited for testing multiple samples at one time.Alert8441 Alert for Almond <strong>Allergen</strong> Screens at 5 ppm total almond 12–20 samples per kit8451 Alert for Egg <strong>Allergen</strong> Screens at 5 ppm whole dried egg 12–20 samples per kit8481 Alert for Gliadin Screens at 10 ppm gliadin 12–20 samples per kit8431 Alert for Peanut <strong>Allergen</strong> Screens at 5 ppm total peanut 12–20 samples per kit8411 Alert for Soy <strong>Allergen</strong> Screens at 10 ppm SPI 12–20 samples per kit8491 Alert for Soy Flour Screens at 5 ppm or 10 ppm soy flour 12–20 samples per kit8471 Alert for Total Milk <strong>Allergen</strong> Screens at 5 ppm or 10 ppm NFDM 12–20 samples per kit8511 Alert for Gliadin R5 Screens at 10 ppm gliadin 12–20 samples per kit


Test Formats and KitsVeratox ® for <strong>Food</strong> <strong>Allergen</strong>sNeogen’s Veratox microwell food allergen test kits are sandwich enzyme-linked immunoassays(S-ELISAs) that require minimal training and a minimum of standard laboratory equipment to producequantitative results in 30 minutes following extraction. The tests provide food processors a methodof easily determining if an ingredient or product has been subjected to cross-contact with a foodallergen. The Veratox format provides easy data tracking and analysis.Veratox8440 Veratox for Almond <strong>Allergen</strong> Quantitative range of 2.5 to 25 ppm total almond Up to 38 samples8450 Veratox for Egg <strong>Allergen</strong> Quantitative range of 2.5 to 25 ppm whole dried egg Up to 38 samples8460 Veratox for Casein Quantitative range of 2.5 to 15 ppm NFDM* Up to 38 samples8480 Veratox for Gliadin Quantitative range of 5 to 50 ppm gliadin Up to 38 samples8420 Veratox for Hazelnut <strong>Allergen</strong> Quantitative range of 2.5 to 25 ppm total hazelnut Up to 38 samples8500 Veratox for Lupine <strong>Allergen</strong> Quantitative range of 2.5 to 25 ppm total lupine Up to 38 samples8400 Veratox for Mustard <strong>Allergen</strong> Quantitative range of 2.5 to 25 ppm mustard Up to 38 samples8410 Veratox for Soy <strong>Allergen</strong> Quantitative range of 10 to 100 ppm SPI Up to 38 samples8490 Veratox for Soy Flour Quantitative range of 2.5 to 25 ppm soy flour Up to 38 samples8430 Veratox for Peanut <strong>Allergen</strong> Quantitative range of 2.5 to 25 ppm total peanut Up to 38 samples8470 Veratox for Total Milk <strong>Allergen</strong> Quantitative range of 2.5 to 25 ppm NFDM Up to 38 samples8510 Veratox for Gliadin R5 Quantitative range of 2.5 to 40 ppm gliadin Up to 38 samples*Conversion factor available to convert results to ppm caseinVersatility of Neogen in Your Factory541 23Incoming Goods and Warehouse1 AUDITING SUPPLY CHAINUse Neogen to verify allergen controls2 INCOMING GOODSUse Neogen to confirm supplierspecifications3 WAREHOUSEUse Neogen to ensure robustingredient segregation and packagingintegrityProcessing and Packaging4 FOOD PREPARATION SURFACEUse Neogen to validate cleaning anddetect cross-contamination5 6 PROCESS EQUIPMENT AND UTENSILSUse Neogen to validate cleaning anddetect cross-contamination


BioKits for <strong>Food</strong> <strong>Allergen</strong>sNeogen’s BioKits microwell food allergen test kits are sandwich enzyme-linked immunoassays(S-ELISAs) with the exception of BLG which is an indirect competitive ELISA. They require minimaltraining and a minimum of standard laboratory equipment to produce quantitative results in 75–180minutes following extraction. The tests provide food processors a method of determining if an ingredientor product has been subjected to cross-contact with a food allergen.BioKits902061Y BioKits BLG Quantitative range of 2.5–40 ppm BLG Up to 43 samples902083N BioKits Almond Quantitative range of 1–20 ppm almond Up to 43 samples902072T BioKits Egg Quantitative range of 0.5–10 ppm egg white protein Up to 43 samples802002Y BioKits Gluten Quantitative range of 3–50 ppm gluten Up to 91 samples902084L BioKits Hazelnut Quantitative range of 1.6–32 ppm hazelnut Up to 43 samples902048Q BioKits Peanut Quantitative range of 1–20 ppm total peanut Up to 91 samples902070X BioKits Sesame Quantitative range of 6–100 ppm sesame Up to 43 samples902076K BioKits Shellfish Quantitative range of 1–20 ppm shellfish protein Up to 43 samples902085J BioKits Walnut Quantitative range of 2.4–120 ppm total walnut Up to 43 samples69781011127 SPILLAGESUse Neogen to ensure verification ofcleaning8 IN-PROCESS AND RE-WORKUse Neogen to detect potential crosscontaminationFinished Product and Warehouse9 FINISHED PRODUCTUse Neogen to verify product labellingclaims10 WAREHOUSEUse Neogen to ensure robust final productsegregation and packaging integrity11 SPILLAGESUse Neogen to ensure verification ofcleaning12 FINISHED PRODUCT SUPPLY CHAINUse Neogen for auditing andenforcement


Managing <strong>Food</strong> <strong>Allergen</strong>sHave You Properly Assessed theRisks?• The number one cause of global food recalls isundeclared food allergens• The costs of non-compliance can be significant• It is an industry standard to minimize “may containlabel ing”Do Your <strong>Allergen</strong> Control SystemsWork?Take control to protect your brand• It is a “duty of care” to address a significant foodsafety risk• <strong>Testing</strong> plays an important part in validating criticaloper ations• Checks take a few minutes and cost very littleWhy Neogen’s <strong>Food</strong> <strong>Allergen</strong> Test Kits?Simple and quick, Neogen’s Reveal and Reveal 3-Dtests can be implemented more often than laboratoryfood allergen testing. They can deliver enhanced confidenceand protection through increased testing ofall the critical elements in the production process in“real-time”. Neogen’s full line of quantitative Veratoxand BioKits assays also provide in-house tools for theallergen-free validation of ingredients, and in-processand finished product.• WHY?For real-time decision making• WHEN?For process control, auditing, inspection,troubleshooting and training• WHERE?In all areas of the process and supply chain• HOW?By anyone, anywhere, minimal to no trainingrequired


Our <strong>Allergen</strong> RangeVeratox is used for the quantitative analysis of allergens. The test is a sandwich ELISA thatprovides exact concentration in parts per million (ppm).Reveal is a single step lateral flow immunochromatographic assay based on a sandwichimmunoassay format. Can be used with the AccuScan ® lateral flow reader.Alert is a screening test that compares up to 5 samples at a time against a known levelof allergen. The test provides visible results that clearly show whether a sample containsmore or less of a specific food allergen than the control provided.Neogen’s BioKits for food allergen kits include two formats. The Reveal 3-D lateral flowtests make it simple to screen for the presence of low levels of allergens in rinses andenvironmental swabs virtually anywhere. Sample preparation and testing take less than10 minutes.The BioKits microwell assay test kits have been developed to quantify precise levels ofallergens in foods.The Dairy School, Auchincruive, Ayr, KA6 5HW, Scotland, UKTel: +44 (0) 1292 525 610 • Fax: +44 (0) 1292 525 602E-mail: info_uk@neogeneurope.com • Web: www.neogeneurope.com© Neogen Corporation, 2010. Neogen, AccuScan, Alert, Reveal and Veratox are registered trademarks and BioKits is a trademark of Neogen Corporation, Lansing, MI 48912. NE762-0411

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!