10.07.2015 Views

AIR ADMITTANCE VALVE - Nicoll

AIR ADMITTANCE VALVE - Nicoll

AIR ADMITTANCE VALVE - Nicoll

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.nicoll.frTechnical Guide i sanitaryGTCEP12GBSanitary<strong>Nicoll</strong>also leadsto serenityAirAdmittanceValveNew generationEnvironmentBuildingPAO <strong>Nicoll</strong> - Octobre 2012- Photo credits : <strong>Nicoll</strong> - Non-contractual documentBUILDINGSANITARYENVIRONMENTHead office and Plants : 37, rue Pierre & Marie Curie - BP 10966 - 49309 CHOLET Cedex // Tél. 02 41 63 73 83 - Fax 02 41 63 73 57Documentation request : info@nicoll.fr // Technical request : tech-com.nicoll@aliaxis.comwith a capital of 7 683 431 e - 060 200 128 RCS Angers


Exceptional flowInstallation inatticsReactiveandperformanceDirect air flow<strong>Nicoll</strong>’s AAVs (both large and small versions) feature aninnovative design and high air flow, based on in-depth researchinto their air ventilation performance (conducted by <strong>Nicoll</strong>’s R&Ddepartment). The innovative shape of this Air Admittance Valveis the end result of this research. It is a truly unique innovationthat breaks with traditional designs.With its unique design, <strong>Nicoll</strong>’s AAV can be installed in attics instead of aroof crossing solution (in accordance with Art 42). This has the followingadvantages :50452Reduced installation time :<strong>Nicoll</strong> CEP100<strong>Nicoll</strong> SAV111CompetitorFlow (l/s)4035302520151050140 50 60 70 80 90 100 120 150 170 200 220 250• No roof work required.• Limited potential conflict between different professions.No roof sealing problems :• No risk of water infiltration through the roof where the roofcrossing solution is installed.Depression (pascals)No heat loss :At the top of the drop pipeAnalysis of valve reaction to depression:• <strong>Nicoll</strong> new generation large format valve (CEP100),• <strong>Nicoll</strong> old generation large format valve (SAV111),• Competitor large format valve..The graph shows how different valves react and the air flowsthat they achieve when a depression occurs inside the drainagenetwork. Depressions in the drainage network cause gurglesand smell reflux.• With energy standards becoming ever stricter (low energyconsumption houses, etc.), this solution eliminates the riskof heat loss through the roof.High resistance to extreme temperatures :• This solution can be installed in attics with no additional frostprotection required (e.g. expanded polystyrene insulation).The silicon membrane is naturally resistant to frost.12The new AAV reacts when a depression of 40 pascalsoccurs (equivalent to a 4 mm water column). The <strong>Nicoll</strong>AAV reacts so quickly that even the network traps (which,in accordance with regulations, are fitted with a 5 cm waterseal) remain undisturbed.When a depression greater than 250 pascals occurs, the<strong>Nicoll</strong> AAV delivers a flow of more than 43 l/s, providing aquick, effective response to the problem within the network.Flow at least equivalent to a ventilation cowl (equivalentdiameter) :• The CEP100 (100/110 diameter) guarantees a flow of 43 l/s(100 diameter version).• A standard roof traverse solution (100 diameter) guaranteesa flow of around 36 l/s.Upstream of sanitary appliancesPhoto courtesy of www.forum-thermographie.net9 Technical Guide i SANITARY ii SANITARY i Technical Guide10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!