VIII-MAINTENANCEThe user is strongly advised to enter into anannual maintenancecontract withthe installeror a specialist company. In this way, theequipmentand theinstallation willbecheckedandcleaned,theburnerwillbesetcorrectly,andtheunitwillgivefullsatisfaction.Itwilloperatein a most economical manner.Operations to be carried out:- Open the fire-box plate- Have your chimney swept regularly, atleast once each year.- Put a brush in horizontally and brush the flue- Brush the interior of the fire-box and removedeposits and dust from the flapinthesmokepipe and in the fire-box.- Possibility of using chemical cleaners withspray products.- Clean and check the burner, following theinstructions in the technical l e a f l e taccompanyingthe equipment.- Replacetheparts.Checkthoroughlyforleaksin the front plate.FLUEC O M B U S T I O NCHAMBERCleaning the flueHave your flue swept regularly, at least onceeach year. Check for leaks in the smoke pipe.EmptyingEmptying the cylinder and the <strong>boiler</strong> is vital ifthere is any risk of frost. For the <strong>boiler</strong>, use adrainage tap located in its lower section.If you are often away, have anti-freeze put inthe installation.RecommendationCheck the water pressure in the installationregularly.The value indicated on the gauge must not beless than 1 bar cold.Combustion characteristicsAftereachtimetheburneriscleaned,thecombustionregulator is checked with measuringand controlinstruments.It is necessary to ensure that:- the flow of fuel is not greater than that indicated-theflamedoesnotlickthewallsofthecombustionchamber- the temperature of fumes is between 180ºC and220ºC- the CO 2content is from 11 to 13% - the fumeindex is less than 1- the burner has to operate in a proper mannerwithoutpulsation andwithout coughing.ATTENTION!Before any intervention, cut off the current tothe <strong>boiler</strong> by means of the main switch.The overheatingthermostat istriggered: checkwater fill, the operationof thecirculator, andthe regulator thermostat.Awarninglightontheburnerislit:thebreakdownarisesfromtheburner.Waitsomeminutesandreset the control relay located at the front ofthe burner. If nothing happens, call yourinstaller or a specialist company.9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!