IPSO16 WASHER<str<strong>on</strong>g>Installati<strong>on</strong></str<strong>on</strong>g> Specificati<strong>on</strong> - Dimensi<strong>on</strong>s shown in millimetresAPPROVED PRODUCTI/16/11/04A - Ventilati<strong>on</strong> Overflow Outlet, B - Soft Water C<strong>on</strong>necti<strong>on</strong> (cold), C - Warm Water C<strong>on</strong>necti<strong>on</strong>, D - Hard Water C<strong>on</strong>necti<strong>on</strong> (cold),E - Electrical C<strong>on</strong>necti<strong>on</strong>, F - Drain Outlet, G - Steam C<strong>on</strong>necti<strong>on</strong>Model IPSO 16Dimensi<strong>on</strong>s (HxWxD) 1038 x 660 x 796mm 1140 x 740 x 880mm (Boxed)Weight Nett/Loaded211kg (465lb)/239kg (527lb)Dynamic bot<str<strong>on</strong>g>to</str<strong>on</strong>g>m load700N/16HzG-Force Low spin/High spin 74/296WaterNo. of inlet valves1 hot & 2 cold (hard & soft)Recommended temperature (Hot water) 60ºCMinimum pressure1.6 bar (25psi)Inlet size3/4” BSPFlow rate14 litres/min per supplyAverage hot c<strong>on</strong>sumpti<strong>on</strong> 27.9 litres per cycleAverage <str<strong>on</strong>g>to</str<strong>on</strong>g>tal c<strong>on</strong>sumpti<strong>on</strong> 110 litres per cycleDrainSize50mmDrain by gravity80litres/minElectrical JLA 16 ManualSingle phase Self-heat 9Kw 240v/50Hz/1ph/45ASelf-heat 6Kw240v/50Hz/1ph/32A (Opti<strong>on</strong>al)Boiler fed240v/50Hz/1ph/10A (Opti<strong>on</strong>al)Steam240v/50Hz/1ph/10A (Opti<strong>on</strong>al)Three phase Self-heat 9Kw 415v/50Hz/3ph + N/20A/ph (Opti<strong>on</strong>al)JLA 16 Coin OperatedSingle phase Boiler fed 240v/50Hz/1ph/10AMo<str<strong>on</strong>g>to</str<strong>on</strong>g>r rating750wattE.C.H.O (If Fitted)Electrical24hr single phase, 13amp fused spur, fitted with a 5amp fuse(not switched)SteamC<strong>on</strong>sumpti<strong>on</strong>7.5Kg/16.5lb cyclePressure90 - 110psiC<strong>on</strong>necti<strong>on</strong>3/8” BSPMinimum <str<strong>on</strong>g>Installati<strong>on</strong></str<strong>on</strong>g> Distance- Rear400mmNoteMachines are supplied as standard with 2 drain c<strong>on</strong>necti<strong>on</strong>s at 80mm and 155mm high. These are maximum heights with <strong>the</strong> levelling feet in place. If <strong>the</strong> 155mmhigh drain is used <strong>the</strong>n it is not necessary <str<strong>on</strong>g>to</str<strong>on</strong>g> fit an external trap. In extreme cases opti<strong>on</strong>al raising legs can be supplied which will increase <strong>the</strong> height by a fur<strong>the</strong>r75mm or 125mm respectfully.


Foundati<strong>on</strong>sThe machine should be sited <strong>on</strong> a solid level floor capable of withstanding it’sloaded weight. (Failure <str<strong>on</strong>g>to</str<strong>on</strong>g> do so will result in a detrimental effect <strong>on</strong> somecomp<strong>on</strong>ent parts and may effect <strong>the</strong> standard warranty). Whilst <strong>the</strong> washer isfree standing it is not advised <str<strong>on</strong>g>to</str<strong>on</strong>g> stand it <strong>on</strong> a metal raising plinth withoutsecuring <strong>the</strong> washer <str<strong>on</strong>g>to</str<strong>on</strong>g> <strong>the</strong> plinth. Wooden floors are acceptable but you mustensure <strong>the</strong>y are solid, level and capable of withstanding it’s loaded weight.Excessively flexible and springy floors will require some additi<strong>on</strong>alstreng<strong>the</strong>ning or support.Service DistanceA minimum service distance of 400mm is <str<strong>on</strong>g>to</str<strong>on</strong>g> be provided behind <strong>the</strong> machine.Water SupplyThe machine is supplied with three water inlet valves, hot, cold hard and coldsoft. If <strong>the</strong>re is no soft water available or it is not needed, <strong>the</strong> soft and hardc<strong>on</strong>necti<strong>on</strong>s must come from <strong>the</strong> same supply. (Do not use plastic ‘Y’ pieces).The machine is fitted with its own Type ‘A’ Air Break System. This means that itcan be c<strong>on</strong>nected directly <str<strong>on</strong>g>to</str<strong>on</strong>g> <strong>the</strong> mains supply. Separate 15mm hot and coldsupplies are required. If more than <strong>on</strong>e machine is <str<strong>on</strong>g>to</str<strong>on</strong>g> be installed, <strong>the</strong>n <strong>the</strong> pipesizes should be increased accordingly. These supplies should terminate in3/4”BSP shut off valves with male threaded ends. If <strong>the</strong> hot water supply isinsufficient in temperature, pressure or flow, <strong>the</strong> machine can <strong>the</strong>n bec<strong>on</strong>nected solely <str<strong>on</strong>g>to</str<strong>on</strong>g> a cold water supply. This can <strong>on</strong>ly be d<strong>on</strong>e if <strong>the</strong> machineis equipped with a heating source, i.e. electric elements or a steam supply.This can however increase cycle times and running costs. A minimum supplypressure of 25psi is required for each supply. If this is not available cycle timeswill increase. To overcome this a booster pump can be fitted: PLEASE SEESPECIFICATION FOR FLOW RATE REQUIRED. The hot and cold suppliesshould be equal <str<strong>on</strong>g>to</str<strong>on</strong>g> within 25psi of each o<strong>the</strong>r. In hard water areas itsrecommended that <strong>the</strong> water supply is fitted with a water softner. Failure <str<strong>on</strong>g>to</str<strong>on</strong>g> doso will result in a detrimental effect <strong>on</strong> some comp<strong>on</strong>ent parts and may effect<strong>the</strong> standard warranty.Steam (Opti<strong>on</strong>al)The machine should be c<strong>on</strong>nected <str<strong>on</strong>g>to</str<strong>on</strong>g> suitably sized live steam supplyutilising an isolating valve, strainer/trap, electric solenoid inlet valve and aflexible steam c<strong>on</strong>necti<strong>on</strong> hose. (Please note n<strong>on</strong>e of <strong>the</strong>se fittings aresupplied with <strong>the</strong> machine). All pipes should be lagged <str<strong>on</strong>g>to</str<strong>on</strong>g> protect againstpers<strong>on</strong>al injury. All steam supply pipes should be installed <str<strong>on</strong>g>to</str<strong>on</strong>g> local andnati<strong>on</strong>al codes of practice as <strong>the</strong>y form part of a pressurised system.NOTES:-1 WHERE EXISTING SERVICES ARE TO BE CONNECTED TO, THEINSTALLER MUST ENSURE THAT THESE ARE ADEQUATELYSIZED AND THAT THEY ARE IN GOOD WORKING ORDER.FOR EXAMPLE, IF A WASHER IS TO BE CONNECTED TO ANEXISTING DRAIN IT MUST BE CHECKED FOR ANY BLOCKAGESDURING INSTALLATION.2 FOR MULTIPLE MACHINE INSTALLATIONS SERVICES MUST BEINCREASED IN SIZE ACCORDINGLY. I.E WATER PIPES,DRAINAGE PIPES,ELECTRIC CABLES ETC.3 ECHO REQUIREMENT,ONLY ONE MACHINE PER SITE WILL BEFITTED WITH AN ECHO ENCLOSURE PANEL.ONLY ONE SEPERATE FUSED SPUR IS REQUIRED PERSITE/ENCLOSURE.NOTE! ALL INSTALLATIONS MUST COMPLY WITH THE NATIONALWATER REGULATIONS.DrainageThe machine is fitted with a gravity drain outlet and must be positi<strong>on</strong>ed higherthan <strong>the</strong> main drain. The drain outlet must be fitted with a “trap” removable forcleaning purposes. This is <str<strong>on</strong>g>to</str<strong>on</strong>g> ensure against odour re-circulati<strong>on</strong>. To meetHealth and Safety guidelines <strong>the</strong> drain must be sealed inside <strong>the</strong> building.Where a foul water supply discharges <str<strong>on</strong>g>to</str<strong>on</strong>g> an outside foul drain or gully, <strong>the</strong>re isno requirement <str<strong>on</strong>g>to</str<strong>on</strong>g> seal <strong>the</strong> system, as it must be ventillated and accessible forcleaning. The underlying trap will prevent foul air from rising from <strong>the</strong> sewer.External gullies may be so placed for <strong>the</strong> displacement of surface or rainwater.The <strong>on</strong>ly excepti<strong>on</strong> <str<strong>on</strong>g>to</str<strong>on</strong>g> this rule is where <strong>the</strong> foul water discharge from <strong>the</strong>machines is under high pressure, thus rendering <strong>the</strong> water seal within <strong>the</strong>gully ineffective.ElectricalEach machine must be individually protected. The isolati<strong>on</strong> point for <strong>the</strong>machine should be in a readily accessible positi<strong>on</strong> for use in an emergency.All cabling <str<strong>on</strong>g>to</str<strong>on</strong>g> <strong>the</strong> machine shall be sufficiently protected against damage.It shall be correctly sized <str<strong>on</strong>g>to</str<strong>on</strong>g> <strong>the</strong> current rating of <strong>the</strong> machine. It should bec<strong>on</strong>nected <str<strong>on</strong>g>to</str<strong>on</strong>g> <strong>the</strong> machine using a suitable cable entry fixing.Circuit breakers orfuses should be used <str<strong>on</strong>g>to</str<strong>on</strong>g> protect <strong>the</strong> power supply. If fuses are used <strong>the</strong>n <strong>the</strong>ymust be of <strong>the</strong> mo<str<strong>on</strong>g>to</str<strong>on</strong>g>r rated variety. A resp<strong>on</strong>sible and competent operativeshould carry out all electrical work and ensure that all local and nati<strong>on</strong>alregulati<strong>on</strong>s and codes of practice are complied with.All <str<strong>on</strong>g>specificati<strong>on</strong></str<strong>on</strong>g>s subject <str<strong>on</strong>g>to</str<strong>on</strong>g> change without notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!