7. Ordering data<br />
For placing orders, please, use the following key:<br />
Single-float Buchholz relays Double-float Buchholz relays<br />
XX -XX<br />
. .. XX .-X<br />
0 X<br />
XX -XX . .. XX.-X<br />
X X<br />
Type code no. Type code no.<br />
(see para. 4) (see para. 4)<br />
Special design Special design<br />
(see table 2) (see table 2)<br />
(There are several (There are several<br />
identif. no. possible, identif. no. possible,<br />
always separated by always separated by<br />
a dot.) a dot.)<br />
Damper setting Damper setting<br />
1= 0.65 m/s 1= 0.65 m/s<br />
2 = 1.00 m/s 2 = 1.00 m/s<br />
3 = 1.50 m/s 3 = 1.50 m/s<br />
4 = 2.00 m/s<br />
5 = 2.50 m/s<br />
6 = 3.00 m/s<br />
0 = not occupied Contact setting of<br />
upper switching<br />
system<br />
1 = one NO-contact<br />
2 = one NC-contact<br />
3 = one change-over<br />
contact<br />
4 = two NO-contacts<br />
5 = one NO- and one<br />
NC-contact<br />
Contact setting of Contact setting of<br />
switching system lower switching system<br />
1 = one NO-contact 1 = one NO-contact<br />
2 = one NC-contact 2 = one NC-contact<br />
3 = two NO-contacts 3 = two NO-contacts<br />
4 = two NC-contacts 4 = two NC-contacts<br />
5 = one NO- and one 5 = one NO- and one<br />
NC-contact NC-contact<br />
6 = one change-over 6 =one change-over<br />
contact contact<br />
7 = two change-over<br />
contacts<br />
Important remark: NO = normally-open<br />
NC = normally-closed<br />
Ordering example:<br />
Buchholz relay 10-22.25.28.-313 Explanation:<br />
10<br />
22<br />
25<br />
28<br />
3<br />
1<br />
3<br />
17<br />
= Designation of a double-float Buchholz relay type 10 (BF 80/Q)<br />
= climatic version<br />
= lower switching system equipped with 2 magnet contact tubes<br />
= Oil drain plug<br />
= Damper setting of 1.50 m/s<br />
= contact setting of upper switching system – 1 NO-contact<br />
= contact setting of lower switching system – 2 NO-contacts