11.07.2015 Views

Download Technical information sheet in pdf format - Scientific ...

Download Technical information sheet in pdf format - Scientific ...

Download Technical information sheet in pdf format - Scientific ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.reformulyzer.comAnalysis Simulation ProgramSelf explanatory operationTra<strong>in</strong><strong>in</strong>g ToolTo tra<strong>in</strong> users on the multi-dimensionaltechnique AC developed the Reformulyzer® M3Analysis Simulation Program.The program demonstrates sample separation thruvarious columns and traps.4The simulation program shows the analysissequence step-by-step.Simultaneously the elution pattern canbe observed <strong>in</strong> the chromatogram.System Ma<strong>in</strong>tenanceAll traps have dedicatedconnectors for easy partsreplacement.


Integrated Diagnostic ToolAutomates validationTo validate the Reformulyzer® M3 performance AC developeda set of quality control (QC) samples and an <strong>in</strong>tegrated diagnostictool.After analysis of the QC samples, the diagnostic tool reports validationand statistical data for:• a specific analysis• a series of analyses over a longer periodThe diagnostic tool will automatically mark results outside specificationlimits. You will f<strong>in</strong>d these marked results <strong>in</strong> the on-screen report.The diagnostic tool also advices on possible causes for componentsexceed<strong>in</strong>g the limits and reviews data for trend record<strong>in</strong>g.Quality Control SamplesAC offers a set of quality controlsamples that covers most lightpetroleum streams:• Reformer feed• Re<strong>format</strong>e• FCC naphtha• Gasol<strong>in</strong>e conta<strong>in</strong><strong>in</strong>g MTBE• Oxygenates free gasol<strong>in</strong>e• Gasol<strong>in</strong>e conta<strong>in</strong><strong>in</strong>g Ethanol• Gasol<strong>in</strong>e conta<strong>in</strong><strong>in</strong>g ETBE &Ethanolwww.reformulyzer.com5“The diagnostic tool alsoadvices on possible causesfor components exceed<strong>in</strong>gthe limits .”AC Reformulyzer® M3 Diagnostic Tool


AC User GroupOptimizes analyzer performanceReformulyzer® users can jo<strong>in</strong> the AC User Group. AC organizesperiodically <strong>in</strong>teractive meet<strong>in</strong>gs that allow users to share andexchange technical knowledge.An important element of the user group is the PerformanceMonitor<strong>in</strong>g Program (PMP): a regular round rob<strong>in</strong> test<strong>in</strong>g on ananonymous base, that assists labs to check their analyzer precision.Results are processed anonymously; AC reports the statisticalvalues and advices on improv<strong>in</strong>g analysis precision.www.reformulyzer.comThe 2005 PMP test consisted of 11 samples. The samples ranged fromfeedstock components such as naphtha, reformer feed, re<strong>format</strong>eand FCC naphtha to 5 gasol<strong>in</strong>e samples conta<strong>in</strong><strong>in</strong>g different levels ofAromatics, Olef<strong>in</strong>s, Benzene and various Oxygenated components.A total of 65 worldwide laboratories participated <strong>in</strong> the PMP.The Reformulyzer® M3 <strong>in</strong>strument was already <strong>in</strong>cluded <strong>in</strong> thismonitor<strong>in</strong>g program.7Reformulyzer® M3 Website Provides Onl<strong>in</strong>e AssistanceUser group participation also <strong>in</strong>cludes access to theReformulyzer® M3 website that provides <strong><strong>in</strong><strong>format</strong>ion</strong> on:• Documents such as brochures, product briefs and application notes• Guidel<strong>in</strong>es and reports of the performance monitor<strong>in</strong>g program


www.reformulyzer.com8Features & Benefits ofAC Reformulyzer® M3AC Analytical Controls BVP.O. Box 10054, 3004 AB RotterdamInnsbruckweg 35, 3047 AG Rotterdamthe NetherlandsPhone : +31-10-462 4811Fax : +31-10-462 6330E-mail : acbv@analytical-controls.comPAC LP8824 Fallbrook Dr.Houston, TX 77064, U.S.A.Phone : +1 281 940 1803Fax : +1 281 580 0719E-mail : sales@paclp.comAC Analytical Controls Asia Pacific Ltd30 Rob<strong>in</strong>son RoadRob<strong>in</strong>son Towers #03-04048546 S<strong>in</strong>gaporePhone : +65-6324-9016Fax : +65-6324-9019E-mail : ac-asia@analytical-controls.comAnalytical CAC Analytical Controls North AsiaWorld Vision Build<strong>in</strong>g #62124-2 Youido-dong, Youngdeungpo-ku150-010 Seoul, KoreaPhone : +82-2-785 3900Fax : +82-2-785 3977E-mai : ac-korea@analytical-controls.com• Full gasol<strong>in</strong>e analysis <strong>in</strong> 75 m<strong>in</strong>utes <strong>in</strong> compliance withASTM D 6839, EN 14517, IP 526 and ISO/AWI 22854• European gasol<strong>in</strong>e specifications (EN 228) list Reformulyzer®EN 14517 data for report<strong>in</strong>g benzene, aromatics and olef<strong>in</strong>s<strong>in</strong> gasol<strong>in</strong>e• Analysis simulation program to support ease of operation• Automated validation thru quality control samples with the<strong>in</strong>tegrated diagnostic tool• Available on the new Agilent Technologies 7890A• Easy parts replacement thru the use of dedicatedconnectors• Columns and traps with extended lifetime• Large <strong>in</strong>stalled base: major oil companies, R&D labs,<strong>in</strong>dependent labs and government agencies• Report options <strong>in</strong>clude hydrocarbon type and oxygenateconcentrations by carbon number and special calculations• AC User Group enables users to share technical knowledgeand optimize performance• A global network of AC certified support eng<strong>in</strong>eerscommissions the system on-site <strong>in</strong> one dayAC Analytical Controls Beij<strong>in</strong>gRepresentative OfficeRm.1003, Sunjoy Mansion No.6RiTan Rd.ChaoYang District, Beij<strong>in</strong>g,P.R. Ch<strong>in</strong>a 100020Phone: +86-10-65072236Fax: +86-10-65072454E-mail: ac-ch<strong>in</strong>a@analytical-controls.com• Instrument is delivered with<strong>in</strong> 3 weeks• One year hardware and application warranty <strong>in</strong>cludes freehelpdesk• Optional on-l<strong>in</strong>e remote support by LAN connection isavailableAC Analytical Controls Thailand25 Floor, M. Thai Tower, All seasons place87 Wireless Road, Lump<strong>in</strong>i, PhatumwanBangkok 10330 ThailandPhone : +66-2-627 9410Fax : +66-2-627 9401E-mail : ac-thailand@analytical-controls.comFor more <strong><strong>in</strong><strong>format</strong>ion</strong>:www.analytical-controls.comwww.reformulyzer.com00.00.0092007 © copyright by AC Analytical ControlsCompany

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!