11.07.2015 Views

TTDM-128 - Pentair Thermal Management

TTDM-128 - Pentair Thermal Management

TTDM-128 - Pentair Thermal Management

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CH01 SIMSIM Normal<strong>TTDM</strong>-<strong>128</strong>13 14 15 16 17 20 21 22 23 24ACACACLeak Location ModuleNetworkAddressACACAC8 9 10 11 12CH01 SIMSIM Normal<strong>TTDM</strong>-<strong>128</strong>13 14 15 16 17 20 21 22 23 24ACACACLeak Location ModuleNetworkAddressACACAC8 9 10 11 12<strong>TTDM</strong>-<strong>128</strong>TRACETEK NETWORK ARRANGEMENT<strong>TTDM</strong>-<strong>128</strong>Master ModuleTTSIMSensor Interface<strong>TTDM</strong>-<strong>128</strong>TTSIMTo additional <strong>TTDM</strong>s,TTSIMs or TT-NRMsSHLDRS–RS+SHLDRS–RS+SHLDRS–RS+SHLDRS–RS+RS-232 orRS-485 modbuslink to hostsystemTTSIM-1RATING: 24Vac 10%50/60 Hz 3VAREDGRNYELBLKGNDTTSIM-1RATING: 24Vac 10%50/60 Hz 3VAREDGRNYELBLKGNDRS-485 2 wire networkDetection cable /sensorsGENERAL FEATURESSensor compatibilityMaximum size of networkNumber of TTSIM modulesMaximum number ofTT-NRMPrecisionUnitsDisplay languageAll TraceTek sensor cables and point sensors or contact closure devices127 (less number of TT-NRMs installed)10± 0.1% of circuit lengthFeet, meters or zonesEnglish, French, German, Spanish, Japanese, ItalianORDERING INFORMATIONCatalog number Part number DescriptionSupply voltage <strong>TTDM</strong>-<strong>128</strong> P000000091 115 V + 15%, - 20% ; 230 V ± 10% ;50/60 Hz<strong>TTDM</strong>-<strong>128</strong>-24V P000000092 24 V AC + 5%, - 35% ; 24 V DC ± 20%Accessories TT-NRM E03411-000 Network relay moduleTTSIM-1 see H56858 Network sensor interface moduleTTSIM-1A see H57387 Network sensor interface module withrelayTTSIM-2 see H57346 Network sensor interface module withrelay<strong>TTDM</strong>-4/20 688799-000 4-20 mA analog output boardTT-SUPERVISOR 591416-000 Windows based PC software<strong>TTDM</strong>-<strong>128</strong> LEAK DETECTION MASTER MODULE4 line x 20 characterbacklit LCD displayFour LEDs (monitoring,service, leak, fault)UserInterface Ribbonboard cableOptional4-20 mAboardSensorInterfaceboardMotherboardPowersupplyboard<strong>TTDM</strong>-<strong>128</strong>CH01 SIMSIM NormalPRI: 220SEC:17PowerMembrane keypadPainted steel NEMA12 enclosureTestportRS-232/485host portRS-485for SIMnetwork4-20mAInterfaceServicerequiredrelayLeak relayFault relay2 / 4EN-TraceTek<strong>TTDM</strong><strong>128</strong>-DS-H56859 09/13THERMAL MANAGEMENT SOLUTIONS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!