11.07.2015 Views

Code Approval of Composite Propane Cylinders for Indoor Use ...

Code Approval of Composite Propane Cylinders for Indoor Use ...

Code Approval of Composite Propane Cylinders for Indoor Use ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

List <strong>of</strong> FiguresFigure 1. Vertically oriented cylinder..........................................................................................12Figure 2. Horizontally oriented cylinder......................................................................................12Figure 3. Steel cylinder, slightly bulged. .....................................................................................12Figure 4. <strong>Composite</strong> cylinder after tests - residual propane contunes to burn.............................12Figure 5. Ruptured two-piece composite cylinder.......................................................................13Figure 6. One piece composite cylinder, no rupture....................................................................13Figure 7. Test site layout showing camera locations relative to cylinder center. ........................14Figure 8. Location <strong>of</strong> wall thermocouples on vertical cylinder...................................................15Figure 9. Location <strong>of</strong> wall thermocouples on horizontal cylinder...............................................16Figure 10. Horizontal calorimeter test setup................................................................................17Figure 11. Vertical calorimeter test setup....................................................................................18Figure 12. Test Type 1 Test Setup...............................................................................................29Figure 13. Standard NFPA 286 Test Room <strong>for</strong> Test Type 2 Test Arrangement .........................31Figure 14. Standard NFPA 286 Test Room <strong>for</strong> Test Type 3 Test Arrangement. ........................33Figure 15. Standard NFPA 286 Test Room <strong>for</strong> Test Type 4 Test Arrangement .........................35List <strong>of</strong> TablesTable 1. Summary <strong>of</strong> Concerns and Comments. ...........................................................................4Table 2. Preliminary <strong>Composite</strong> Cylinder Testing Fire Conditions. ...........................................10Table 3. <strong>Composite</strong> Cylinder Test Plan .......................................................................................11Table 4. Summary <strong>of</strong> test conditions ...........................................................................................19Table 5. Test Variations <strong>for</strong> Test Type 1 .....................................................................................30Table 6. Test Variations <strong>for</strong> Test Type 2 .....................................................................................31Table 7. Test Variations <strong>for</strong> Test Type 3 .....................................................................................33Table 8. Summary <strong>of</strong> Test Type 1 Results...................................................................................38Table 9. Summary <strong>of</strong> Test Type 2 Results...................................................................................39Table 10. Summary <strong>of</strong> Test Type 3 .............................................................................................40<strong>Composite</strong> <strong>Propane</strong> <strong>Cylinders</strong> xiii February 2007<strong>for</strong> <strong>Indoor</strong> <strong>Use</strong> — Phase IIBattelle

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!