11.07.2015 Views

M-Series Circuit Breaker [pdf] - carlingtech.com

M-Series Circuit Breaker [pdf] - carlingtech.com

M-Series Circuit Breaker [pdf] - carlingtech.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

10 | M-<strong>Series</strong> Handle/Pushbutton UL489A/UL Recognized – Ordering SchemeM M 1 – B 14 – 620 – 1 – 1 B B – B – J1<strong>Series</strong>2Actuator3Poles4<strong>Circuit</strong>5Frequency& Delay6CurrentRating7Terminal8ActuatorColor910Front Panel LegendHardware Plate11BushingColor12AgencyApproval1 SERIESM2 ACTUATOR 17 TERMINAL 41 Push-On 0.250 Tab (Q.C.)2 Screw 8-32 w/upturned lugs3 Screw 8-32 (Bus Type)A 10P 11Push-In StudPrinted <strong>Circuit</strong> BoardHandleMPaddlePush ButtonT Push-PullPush Button w/ Snap-In MountingV Push-PullNUWBatonPush To ResetPush To Reset8 ACTUATOR COLOR & LEGEND 5Gloss Handle Push-Button1A2B3C4D5E6F8HAcuator ColorWhiteBlackRedGreenBlueYellowOrange3 POLES1 One4 CIRCUITwithout Auxiliary SwitchB <strong>Series</strong> Trip (Current)with Auxiliary Switch, Silver Contacts Terminal Type:M <strong>Series</strong> Trip (Current) Aux Switch .110 QC x .020 QCS 2 <strong>Series</strong> Trip (Current) .060 Dia, Round Solder TurretT 2,3 <strong>Series</strong> Trip (Current) .058 Dia, Round Q.C.U 3,12 <strong>Series</strong> Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.with Auxiliary Switch, Gold Contacts4 2,3 <strong>Series</strong> Trip (Current) .058 Dia, Round Q.C.5 3,12 <strong>Series</strong> Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.9 <strong>Series</strong> Trip (Current) Aux Switch .110 QC x .020 QC5 FREQUENCY & DELAY12 DC Short14 DC Medium6 CURRENT RATING (AMPERES)CODEAMPERES020 0.020025 0.025030 0.030035 0.035040 0.040045 0.045050 0.050055 0.055060 0.060065 0.065070 0.070075 0.075080 0.080085 0.085090 0.090090 0.095210 0.100215 0.150220 0.200225 0.250230 0.300235 0.350240 0.400245 0.450250 0.500255 0.550260 0.600265 0.650270 0.700275 0.750280 0.800285 0.850290 0.900295 0.950410 1.000512 1.250415 1.500517 1.75072 DC, Short,Hi-Inrush74 DC,Medium, Hi-Inrush420 2.000522 2.250425 2.500527 2.750430 3.000435 3.500440 4.000445 4.500450 5.000455 5.500460 6.000465 6.500470 7.000475 7.500480 8.000485 8.500490 9.000495 9.500610 10.000710 10.500611 11.000711 11.500612 12.000712 12.500613 13.000614 14.000615 15.000616 16.000617 17.000618 18.000620 20.000622 22.000624 24.000625 25.000630 30.0009 FRONT PANEL HARDWARE 6No outer Panel HardwareKnurled NutBright nickelBright nickel w/ locking ringBlackBlack w/ locking ringPanel Dress NutBright nickelBright nickel w/ locking ringBlackBlack w/ locking ring11 BUSHING COLOR 7B BlackHandleABCDEFGHJ12 AGENCY APPROVAL 9J UL489A Listed, TUV CertifiedM UL Recognized, CSA AcceptedN UL Recognized, TUV CertifiedT UL489A ListedPush-Button110 LEGEND PLATE / BUTTON MARKINGHandle Actuator Legend Plate (Actuator Styles M & N)A No Legend PlateB ON - OFF VerticalC ON - OFF HorizontalD I - O VerticalE I - O HorizontalPush-Pull Actuator Button Cap (Actuator Styles T & V)1 8 No Marking2 Rated Amps Horizontal3 Rated Amps Line Side Down4 Rated Amps Line Side UpPush-to-Reset Actuator Button (Actuator Styles U& W)1 8 No Marking2Notes:1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited tosingle pole breakers only.2 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switchmounting is in pole one. Auxiliary Switch option limited to <strong>Series</strong> Trip and Switch Only circuits.Not available with Back Connected Screw or Push-in Stud terminals.3 Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated) and60983-3 (tin plated).4 Screw terminals or Push-in Stud re<strong>com</strong>mended above 20 amps.5 Actuator color is only visible in the OFF position on Push-Pull actuators.6 All units have one hex nut installed on bushing for use behind the panel.7 Other colors available. Consult factory.8 Not available with UL489A Listed breakers.9 TUV certified to 25 amps. UL Recognized, CSA Accepted and UL Listed to 30 amps.10 Terminal code A available with circuit codes A & B only.11 Printed circuit board available with UL recognized approval only.12 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!