11.07.2015 Views

M-Series Circuit Breaker [pdf] - carlingtech.com

M-Series Circuit Breaker [pdf] - carlingtech.com

M-Series Circuit Breaker [pdf] - carlingtech.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2 |M-<strong>Series</strong> <strong>Circuit</strong> <strong>Breaker</strong> - General SpecificationsElectricalMaximum Voltage 125/250 VAC 50/60 Hz, 80 VDC(See Rating Tables.)Current Ratings Standard current coils: 0.100,0.250, 0.500, 0.750, 1.00 thru 15.0in 1 amp increments, 18.0, 20.0,25.0, 30.0. Other ratings available- see Ordering Scheme.Auxiliary Switch Rating SPDT; 7A 250VAC, 7A (Res)28VDC, 4A (Ind.) 28VDC, 0.25A80VDC (Res) (silver contacts),0.1A 125VAC (gold contacts).Insulation Resistance Minimum of 100 Megohms at 500Dielectric StrengthRESISTANCE PER POLE VALUESfrom Line to Load Terminals(Values Based on <strong>Series</strong> Trip <strong>Circuit</strong> <strong>Breaker</strong>)*Manufacturer reserves the right to change product specification without prior notice.VDC.UL, CSA 1500V, 50/60 Hz for oneminute between all electricallyisolated terminals. M-<strong>Series</strong><strong>Circuit</strong> <strong>Breaker</strong>s <strong>com</strong>ply with the8mm spacing and 3750 V 50/60Hzdielectric requirements fromhazardous voltage to operatoraccessible surfaces, perPublications IEC 380, 435, 950,EN 60950 and VDE 0805.Resistance, Impedance Values from Line to Load Terminal- based on <strong>Series</strong> Trip <strong>Circuit</strong><strong>Breaker</strong>.Pulse Tolerance CurvesCURRENT TOLERANCE(AMPS) (%)0.10 - 20.0 ±2520.1 - 50.0 ±35MechanicalEndurance 10,000 ON-OFF operations @ 6per minute with rated Current andVoltage.Trip FreeAll M-<strong>Series</strong> <strong>Circuit</strong> <strong>Breaker</strong>s willtrip on overload, even whenactuator is forcibly held in the ONposition.Trip IndicationThe actuator moves positivelyto the OFF position when anoverload causes the circuitbreaker to trip.PhysicalNumber of Poles 1 or 2Internal <strong>Circuit</strong> Configs. <strong>Series</strong> with or withoutAuxiliary Switch.Switch Only with or withoutAuxiliary Switch.WeightApproximately 30 grams/pole(Approximately 1.07 ounces/pole)Standard Colors See Ordering Scheme.aEnvironmentalDesigned in accordance with requirements of specificationMIL PRF-55629 & MIL-STD-202G as follows:ShockWithstands 100 Gs, 6ms, sawtoothwhile carrying rated current perMethod 213, Cond. I. Instantaneouscurves tested at 80% of ratedcurrent.VibrationWithstands 0.060” excursionfrom 10-55 Hz, and 10 Gs 55-500Hz, at rated current per Method204C, Test Condition A.Instantaneous curves tested at80% of rated current.Moisture Resistance Method 106D, i.e., ten 24-hourcycles @ + 25°C to +65°C, 80-98% RH.Salt Spray Method 101, Condition A (90-95%RH @ 5% NaCl Solution, 96 hrs).Thermal Shock Method 107D, Condition A (Fivecycles @ -55°C to +25°C to +85°Cto +25°C).Operating Temperature -40° C to +85° CChemical Resistance Only the outside surfaces of thecase and the handles may becleaned with detergents oralcohol. Organic (hydrocarbonbased) solvents are notre<strong>com</strong>mended because theyattack plastics. Caution shouldbe taken when solvents are usedto clean and remove flux fromterminals. Lubricants should notbe introduced into the handle/bushing openings60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231Email: sales@<strong>carlingtech</strong>.<strong>com</strong> • www.<strong>carlingtech</strong>.<strong>com</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!