11.07.2015 Views

Custom Actuator Products, Inc. - Norman Equipment Co.

Custom Actuator Products, Inc. - Norman Equipment Co.

Custom Actuator Products, Inc. - Norman Equipment Co.

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CUSTOM ACTUATOR PRODUCTS, INC.SERIES 5000 Open Loop <strong>Co</strong>ntrol DevicesCUSTOM ACTUATOR PRODUCTS, INC.SERIES 5000 Open Loop <strong>Co</strong>ntrol DevicesDual Set Point <strong>Co</strong>ntrollerInfinitely adjustable within cylinder strokeScalable Analog Output <strong>Co</strong>ntrollerFor continuous position outputThe Cyclon Series 5000 open loop controllers provide either an analog position output signal or two trip pointswhen combined with a <strong>Custom</strong> <strong>Actuator</strong> <strong>Products</strong> Linear Position Transducer. The small size of the Series 5000and simple electrical hook-up make this linear position motion control device very easy to install and operate.Each unit is provided with an Installation manual.Scalable Analog Output <strong>Co</strong>ntroller withDigital MeterProvides convenient digital display of scaled outputsignal. Display can be either 0-10Vdc or 4-20mA.Meter is 0.875" x 2.000". To order indicate an M afterthe Standard Model code.Scalable Analog Output and Dual SetPoint <strong>Co</strong>ntroller<strong>Co</strong>mbines most of the features of the Standard Dual SetPoint <strong>Co</strong>ntroller and Scalable Analog Output <strong>Co</strong>ntrollerinto one convenient package.The Set Point model offers the advantage of infinitelyadjustable, dual trip points anywhere along the stroke ofthe cylinder rather than only two fixed points as providedby end-of-stroke models. The set-point model is availablewith either 2-Triac, 2-relay or 2-transistor outputs.<strong>Co</strong>ntrol units are designed with either a single turn, setpointpotentiometer or an optional multi-turn potentiometerfor applications that require more resolution. Series5000 also has a non-scalable, 0-10 Vdc analog output.OrderNo.OutputTypeSet AdjustmentInputPower5001 Relay Standard Pot. +15Vdc5002 Relay High Precision Pot. +15Vdc5003 Relay Standard Pot. 115Vac5004 Relay High Precision Pot. 115Vac5005 Triac Standard Pot. +15Vdc5006 Triac High Precision Pot. +15Vdc5007 Triac Standard Pot. 115Vac5008 Triac High Precision Pot. 115Vac5009 Transistor Standard Pot. +15Vdc5010 Transistor High Precision Pot. +15Vdc5011 Transistor Standard Pot. 115Vac5012 Transistor High Precision Pot. 115VacThe Analog Position Indicator model offers you ascalable output that can be passed to a meter, PLC orother device. Standard outputs are -10 to +10Vdc, 0 to+10Vdc, and 4 to 20mA. A variety of AC and DC power inputoptions are available. The system's output is scalableover the stroke of the cylinder providing a full scale linearposition output between two points.A unique feature of this control system provides for scalingbetween two selected points that do not need to be end-ofstroke.OrderNo. Output Input Power5019 0 to +10Vdc +9Vdc to +36Vdc5020 -10 to +10Vdc +15 and -15Vdc5021 -10 to +10Vdc 115Vac5022 0 to +10Vdc +15 and -15Vdc5023 0 to +10Vdc 115Vac5024 4 to 20mA 115Vac5025 4 to 20mA +15 and -15Vdc5026 -5 to +5Vdc +15 and -15Vdc5027 -5 to +5Vdc 115Vac5028 -10 to +10Vdc +24 and -24Vdc5029 4 to 20mA +9Vdc to +36VdcNote:For strokes of 2 inches or less please order theshort stroke model by adding an S to themodel code.Series 5000-5012 and 5019-5029SpecificationsOUTPUT SPECIFICATION-SET POINT:RELAY (2)3 AMP @ 28VDC5 AMP @ 115VACTRIAC (2)2 AMP (60-115VAC)TRANS. (2)10mAOUTPUT SPECIFICATION-ANALOG OUTPUT:0 to 10V, 1mA max. output current (10K ohm impedance MIN.)-10 to +10V, 1mA MAX. output current (10K ohm impedance MIN.)4 to 20mA, into 500 ohm impedance MAX.POWER INPUT REQUIREMENTS:AC (all units) 115V 60Hz .1 AMPDC (set-point systems) +15VDC .1 AMPDC (indicator systems) +15VDC and -15VDC 40mA each supply4 to 20mA SYSTEM +15VDC and -15VDC 50mA each supplyENCLOSURE DIMENSIONS: 3" H X 5 5/8" W X 4" DMOUNTING HOLES: 3 9/16" X 4 7/8" ctr to ctr 4 placesSHIPPING WEIGHT: WITH METER2 lbs. 3 lbs.INPUT FUSE: .250 AMPELECTRONICS TEMPERATURE OPERATING RANGE:40 ° F to 130 ° FModel 5013-5016 SpecificationsENCLOSURE DIMENSIONS:SHIPPING WEIGHT:1.31" H x 5.50"W x 3.25"D8 9.80 lbs.POWER INPUT REQUIREMENTS:(AC MODELS)120Vac 60 Hz.1 AMP(DC MODELS) 12 or 24Vdc .1 AMPINPUT FUSE:.250 AMPOUTPUT SPECIFICATION - SET POINT:RELAY (2)6 AMP @ 30 VDCOUTPUT SPECIFICATIONS - ANALOG:0 to 10Vdc, 10mA MAX output current4 to 20mA @ 500 ohm MAX loop resistanceMAXIMUM ZERO OFFSET: 50% of cylinder strokeMINIMUM SPAN RANGE: 50% of cylinder strokeELECTRONICS TEMPERATURE OPERATING RANGE: 40 F to 130 FMODEL INPUT SCALABLENUMBER POWER OUTPUT5013 12-24 VDC 0-10 VDC5014 12-24 VDC 4-20 mA5015 120 VAC 0-10 VDC5016 120 VAC 4-20 mA5017 115VAC 0 to (-)10 VDCIMPORTANT NOTE:The series 5000 unit or similar device has 2 features that are important to the long life and accuracy of your feedback system.1) It provides a regulated dc voltage to the LRT/MLRT and 2) It provides a high impedance interface of 1 Megaohm limitingthe current draw through the wiper contacts.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!