sufficient slack should be left inside the joint box to prevent excess tension on<br />

conductors<br />

cables should be inserted so that they are not crossing; they should be neat <strong>and</strong><br />

fitted so that the lid fits without causing damage<br />

correct size joint boxes should be used<br />

joint boxes should be secured to a platform fitted between the floor <strong>and</strong> ceiling joists.<br />

Phase<br />

Neutral<br />

cpc<br />

switch<br />

switch feed switch wire<br />

Joint box<br />

Neutral<br />

Figure 6.16 illustrates the control of one light via a one-way switch using this method.<br />

Rings, radials <strong>and</strong> spurs<br />

Before the early 1950s different types <strong>and</strong> sizes of socket outlet <strong>and</strong> plug were in use<br />

in domestic premises, which was very annoying <strong>and</strong> inconvenient! In 1947, 5 A <strong>and</strong><br />

15 A socket outlets were deemed obsolete, <strong>and</strong> agreement was reached on a st<strong>and</strong>ard<br />

13 A socket outlet with a fused plug, to BS 1363. In this section we will be looking at<br />

the st<strong>and</strong>ard power-circuit arrangements found in domestic premises. In particular<br />

the following will be investigated:<br />

●<br />

●<br />

●<br />

ring circuits<br />

Figure 6.16 One-way switch using a joint box<br />

permanently connected equipment<br />

non-fused spurs<br />

Ring circuits<br />

●<br />

●<br />

fused spurs<br />

radial circuits.<br />

In this system the phase, neutral <strong>and</strong> circuit protective conductors are connected<br />

to their respective terminals at the consumer unit, looped into each socket outlet<br />

in turn <strong>and</strong> then returned to their respective terminals in the consumer unit, thus<br />

forming a ring. Each socket outlet has two connections back to the mains supply.<br />