<strong>NVQ</strong>2 Electrical Installations<br />
132<br />
●<br />
●<br />
●<br />
●<br />
sufficient slack should be left inside the joint box to prevent excess tension on<br />
conductors<br />
cables should be inserted so that they are not crossing; they should be neat <strong>and</strong><br />
fitted so that the lid fits without causing damage<br />
correct size joint boxes should be used<br />
joint boxes should be secured to a platform fitted between the floor <strong>and</strong> ceiling joists.<br />
Phase<br />
Neutral<br />
cpc<br />
switch<br />
switch feed switch wire<br />
Joint box<br />
Neutral<br />
Figure 6.16 illustrates the control of one light via a one-way switch using this method.<br />
Rings, radials <strong>and</strong> spurs<br />
Before the early 1950s different types <strong>and</strong> sizes of socket outlet <strong>and</strong> plug were in use<br />
in domestic premises, which was very annoying <strong>and</strong> inconvenient! In 1947, 5 A <strong>and</strong><br />
15 A socket outlets were deemed obsolete, <strong>and</strong> agreement was reached on a st<strong>and</strong>ard<br />
13 A socket outlet with a fused plug, to BS 1363. In this section we will be looking at<br />
the st<strong>and</strong>ard power-circuit arrangements found in domestic premises. In particular<br />
the following will be investigated:<br />
●<br />
●<br />
●<br />
ring circuits<br />
Figure 6.16 One-way switch using a joint box<br />
permanently connected equipment<br />
non-fused spurs<br />
Ring circuits<br />
●<br />
●<br />
fused spurs<br />
radial circuits.<br />
In this system the phase, neutral <strong>and</strong> circuit protective conductors are connected<br />
to their respective terminals at the consumer unit, looped into each socket outlet<br />
in turn <strong>and</strong> then returned to their respective terminals in the consumer unit, thus<br />
forming a ring. Each socket outlet has two connections back to the mains supply.<br />
Lamp