Series 9820Q ASTRA Installation/Operation Manual - Gasboy
Series 9820Q ASTRA Installation/Operation Manual - Gasboy
Series 9820Q ASTRA Installation/Operation Manual - Gasboy
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Pump <strong>Operation</strong>Battery Back-Up Power Supply<strong>9820Q</strong> models can be equipped with an optional battery back-up power supply. This allows thelast transaction data to be displayed for a minimum of 15 minutes. After the batteries reach acertain low-voltage point, the power will automatically shut off. If you need to shut off the batterypower before the low-voltage point is reached, momentarily disconnect, then re-connect, the cablethat plugs into P1 on the power supply.View/Reset TotalizerElectronic TotalizerThe <strong>9820Q</strong> stores a running quantity total. This electronic totalizer works independent of theoptional mechanical totalizer that may be installed, and is shown as whole gallons (liters) on thedisplays (decimal point is shown, although it is disregarded). The totalizer data is stored inbattery-backed memory. The <strong>9820Q</strong> is supplied with an actuator (shown in the above illustration)which allows you to view and reset the electronic totalizer. When the <strong>9820Q</strong> is shipped, theactuator is attached with a tie wrap to the electronic chassis behind the register door. Atinstallation or startup, cut the tie wrap and remove actuator. Retain for future use.MDE-4339 <strong>9820Q</strong> <strong>ASTRA</strong> <strong>Installation</strong>/<strong>Operation</strong> • July 2004 33