FunctionsBCEnergy hold off Digital input di1 all <strong>CR24</strong>-..AC 24 V+~NTCEnergy hold offIf a local detector (e.g. a window switch) acts on the digital input di1and closes the corresponding contact, the <strong>room</strong> is adjusted to thebuilding protection settings in energy saving mode, in other words theheating setpoint is significantly reduced (15°C) or the cooling setpointsignificantly increased (40°C), though not sufficiently to cause damageto sensitive objects (plants, paintings etc.).10201 2Y [V]W A.V max.V min3ai/di1t R [°C]ZuEnergy hold off<strong>CR24</strong>-B..KeyY Output signalt R Room temperatureW A Current setpointTypical applications– A window switch at di1 stops all energy consumption from the momentthe window is opened until the lower or upper building protectionlimit is reached.– Higher-level override command, e.g. building management system.Notes– The minimum VAV output is set to 0 V instead of 2 V while energyhold off is active (forced closing in 2...10 V)– The mode switch (operator level 1) is deactivated while energy holdoff is active (input di1 takes priority).– If an external temperature sensor is used, the frost limit is monitoredby the internal sensor while energy hold off is active.– Due to the automatic sensor detection the change into Energy holdoff takes about 40 seconds.Stand-by Digital input di2 all <strong>CR24</strong>-..AC 24 V+~If a local detector (e.g. a motion detector) acts on the digital input di2and closes the corresponding contact, the <strong>room</strong> is adjusted to thestand-by settings, in other words the heating setpoint is reduced by 2 Kor the cooling setpoint is increased by 3 K.Stand-by4di2Typical applications– A motion detector, a light switch or another detector at di2 reducesthe energy consumption of unoccupied <strong>room</strong>s.– Higher-level override command, e.g. building management system.1 2<strong>CR24</strong>-B..1020Y [V]108.420Y [V]ao3ao1W Aao2W AStand-by.V max.Vminao1t R [°C].V maxVmint R [°C]Key. KeyY Output signalt R Room temperatureW A Current setpointVAV function: air volume in heating mode (Reheater) max heatingY Output signalt R Room temperatureW A Current setpoint<strong>CR24</strong>-B2 and <strong>CR24</strong>-B3 onlyIf the selected application requires an increased air volume for heating,e.g. for:– Providing or assisting heating with air.– Improving the air quality during heating.<strong>CR24</strong>-B2 configurationThe VAV function is configured using DIP switch 2.<strong>CR24</strong>-B3 configurationThe VAV function is configured using DIP switch 2.1 21 2 3 4 56ENG-93001-93427-08.04-2M • Printed in Switzerland • ZSD • Subject to technical modifications12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!