11.07.2015 Views

DATA BOOK - BVT Partners OÜ

DATA BOOK - BVT Partners OÜ

DATA BOOK - BVT Partners OÜ

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

'11 • SCM-DB-109ModelItemSCM80ZJ-S1Cooling capacity (1) W 8000 (1800 (Min.)~9200 (Max.))Heating capacity (1) W 9300 (1500 (Min.)~9800 (Max.))Power supply1 Phase, 220~240 V, 50HzPowerCooling2.16 ( 0.48~2.83 )kWconsumption Heating 2.26 ( 0.60~3.43 )RunningCooling9.9 / 9.4 / 9.0 (220/ 230/ 240 V)currentHeating 10.4 / 10.0 / 9.5 (220/ 230/ 240 V)AInrush current 10.4 / 10.0 / 9.5 (220/ 230/ 240 V)Max current (5) 20Operationdata (1)COPNoiselevelCoolingHeatingCooling 3.70Heating 4.12Sound level dB(A) 54Power level dB 66Sound level dB(A) 54Power level dB 66Exterior dimensions (Height x Width x Depth) mm 750 x 880 x 340Exterior appearance(Munsell color)Stucco white( 4.2Y 7.5/1.1 ) near equivalentNet weight kg 62RefrigerantequipmentAir handlingequipmentAdapted to RoHS directiveCompressor type & Q'ty RM-T5118MDE2 (Twin rotary type) x 1Motor (Starting method) kW 1.4 (Line starting)Refrigerant oil0.675 (DIAMOND FREEZE MA68)Refrigerant (4) kg R410A 3.15 (Pre-Charged up to the piping length of 40m)Heat exchangerM fins & inner grooved tubingRefrigerant controlCapillary tubes + Electronic expansion valveDevice controlMicrocomputer controlFan type & Q'ty Propeller fan x 1Motor W 86Air flowCooling56.0CMMHeating 56.0Cushion rubber (for compressor)Shock & vibration absorberElectric heater Crank case heater (220V 20W )Safety devicesInstallationdataCompressor overheat protection, Overcurrent protection,Frost protection, Serial signal error protection, Outdoor fan motor error protection,Heating & Cooling overload protectionRefrigerant piping size (O.D) mmLiquid line: 6.35 (1/4") × 4Gas line: 9.52 ( 3/8" ) × 4Connecting methodFlare connectingInsulation for pipingNecessary (Both sides), independentLength for one indoor unitMax. 25Total length for all rooms Max. 70Vertical height difference betweenoutdoor unit and indoor unitmMax. 20 (Outdoor unit is higher)Max. 20 (Outdoor unit is lower)Height difference of the indoor units Max. 25Recommended breaker size A 25Connection wiringSize x Core number1.5mm 2 x 4 cores (Including earth cable)Connecting methodTerminal block (Screw fixing type)Accessories (included) Union : (9.5212.7) × 2, Installation sheet, Elbow, Grommet × 2SRK20,25,35ZJX-S,50,60ZJX-S1SRK25,35ZJR-SSRK20,25,35,50ZJ-SIndoor unit to be combinedSRF25,35ZJX-S,50ZJX-S1SRR25,35,50,60ZJ-SFDTC25,35,50,60VDFDEN50VD,FDUM50VFNumber of connectable indoor units Min. 2~Max. 4Total of indoor units kW Max. 13.5Note (1) The data are measured at the following conditions.Item Indoor air temperature Outdoor air temperatureOperationDB WB DB WBCooling 27 19 35 24Heating 20 — 7 6(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) The operation data are applied to the 220/230/240V districts respectively.(4) The refrigerant quantity to be charged includes the refrigerant in 40m connecting piping.(Purging is not required even for the short piping.)(5) Current value at maximum number of indoor units connected.The pipe length for one indoor unit is 7.5m.StandardsISO-T1, JIS C 9612RWC000Z235- 9 -g

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!