11.07.2015 Views

Analtech Catalog.pdf

Analtech Catalog.pdf

Analtech Catalog.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Modifiied Silica Plates<strong>Analtech</strong> manufactures a number of modified silica gelson a routine basis. Often the addition of some specificmaterial to the base adsorbent aids in discrimination ofparticular analytes. The most commonly used modifiedplates are listed here. Modification can be accomplishedin two ways. The additive material can be dissolved inthe solution used to prepare the spreading slurry, or afinished TLC plate can be impregnated with the desiredagent. If you have some particular requirement other thanthose shown, call <strong>Analtech</strong> for prices and delivery.Sodium Hydroxide (0.1N) ModifiedSilica Gel G & GF UNIPLATESInstead of water, 0.1 N sodium hydroxide is used toprepare the slurry for these plates. This makes the platesmore basic and contributes to improved separation ofcertain compounds, particularly organometallics andsome acidic classes.25 Plates/Box, 250μm Thickness, 10μm particle, 60Å porePlate Size(cm) <strong>Catalog</strong> g number gf20 x 20 68011 6901110 x 20 68021 690215 x 20 68031 69031Carbomer (0.33%) ModifiedSilica Gel H UNIPLATESThese very specialized plates are prepared according toseveral Pharmacopoeia methods. They are used in theanalysis of mannitol/sorbitol.NOTE: These plates are very fragile and will mostdefinitely arrive with silica flaked off of the plate. Thishas always been the case with these very custom TLCplates. This warning is given because these plates are notreturnable.25 Plates/Box, 750μm Thickness, 20x20 cm, 19μm particle, 60Å pore<strong>Catalog</strong> #70019Silver Nitrate Impregnated (%) Silica Gel UNIPLATES (for Argentation Chromatography)These UNIPLATES are impregnated with between 5% and 20% silver nitrate which modifies the separation characteristics of theadsorbent layer to permit increased discrimination of certain compounds, particularly those containing carbon-carbon double bonds.They are available with or without a fluorescent indicator.NOTE: The concentration of silver nitrate (5, 10, 15 or 20%) must be specified at the time of order.25 Plates/Box, 10μm, 60Å pore, 250μm Thickness unless notedPlate Size(cm)<strong>Catalog</strong>No. w/o f<strong>Catalog</strong>no. w/ f20 x 20 28011 2901110 x 20 28021 290215 x 20 28031 29031Preparative (500µm)20 x 20 28012 29012Preparative (1000µm)20 x 20 28013 2901314

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!